NBS Source
I'm a manufacturer

Structural Waterproofing - Private Residence

OVERVIEW

The Scope of the project was to provide a structural waterproofing solution to a private dwelling with new build extension.


The property, situated on a sloping site gave the opportunity for the waterproof design to utilise the properties environment to allow for natural discharge of any potential water ingress.


The property was detached and retaining to the front and side elevations where the retaining ground slopes down and away from the property to a garden that continues to slope down to a small stream. The retaining walls on either elevation rise at their highest point to approximately 1500mm above the internal floor level.


The internal walls of the property were original brick to the front and new cavity built concrete block. The floor to what was the original house is of solid concrete construction joining on to a newer block and beam floor construction.

When designing the most appropriate waterproofing system to any given situation, various design factors require addressing such as (but not limited to), final use of the building, the grade of waterproofing requirement under the British Standard, structural considerations based on the form of construction and in some cases, satisfying the requirements of building warranty providers.

Products featured in this case study

View all products (76)
Delta Channel System

Delta Channel System

Delta Dual V3 Packaged Pump Station

Delta Dual V3 Packaged Pump Station

Delta Foul V3 - Package Pump Station

Delta Foul V3 - Package Pump Station

Delta MS20 - Cavity Drainage Membrane

Delta MS20 - Cavity Drainage Membrane

Koster Polysil TG 500

Koster Polysil TG 500

More inspiration from Delta Membrane Systems Ltd

View inspiration
Basement Waterproofing

Basement Waterproofing

Flood Recovery – Grade II Listed Building

Flood Recovery – Grade II Listed Building

BRE Flood Reilient Test Home

BRE Flood Reilient Test Home

The Gunnery, Kent

The Gunnery, Kent

More inspiration from High-density polyethylene (PE-HD) studded sheets

View inspiration
Waterproofing the London School of Economics

Waterproofing the London School of Economics

Structural Waterproofing Mixed Commercial Development

Structural Waterproofing Mixed Commercial Development

Remedial Basement Waterproofing

Remedial Basement Waterproofing

Future Proofing Waterproofing Multi Level Commercial New Build Structure

Future Proofing Waterproofing Multi Level Commercial New Build Structure

More inspiration from Floor channels

View inspiration
Waterproofing a 116-Bed Care Home, London

Waterproofing a 116-Bed Care Home, London

Basement Extension to a Grade 2 Listed Building, London

Basement Extension to a Grade 2 Listed Building, London

Structural Waterproofing Mixed Commercial Development

Structural Waterproofing Mixed Commercial Development

375 Kensington High Street

375 Kensington High Street

More inspiration from Packaged pumping stations

View inspiration
Basement Extension to a Grade 2 Listed Building, London

Basement Extension to a Grade 2 Listed Building, London

Structural Waterproofing Mixed Commercial Development

Structural Waterproofing Mixed Commercial Development

Remedial Basement Waterproofing

Remedial Basement Waterproofing

More inspiration from Slip plane bituminous emulsion paint primers

View inspiration
Structural Waterproofing Mixed Commercial Development

Structural Waterproofing Mixed Commercial Development

Remedial Basement Waterproofing

Remedial Basement Waterproofing