NBS Source
I'm a manufacturer

Compare variants

Metsec SFS infill wall with Klasse G-Board sheathing board, British Gypsum Gyproc plasterboard
Metsec SFS infill wall with Klasse G-Board sheathing board, British Gypsum Gyproc plasterboard
Metsec SFS infill wall with Klasse G-Board sheathing board, British Gypsum Gyproc plasterboard

Verified 1 month ago

Metsec (voestalpine Metsec)

Verified 1 month ago

Metsec (voestalpine Metsec)

Verified 1 month ago

Metsec (voestalpine Metsec)
Summary
Metsec SFS infill wall with Klasse G-Board sheathing board and British Gypsum Gyproc lining.
-
-
Application

SFS infill wall with plasterboard lining.

-
-
Description

Metsec SFS infill wall with Klasse G-Board sheathing board and British Gypsum Gyproc lining.

 

Resistance to Fire

voestalpine Metsec’s fire test data for infill walling is to BS EN 1364‑1:2015. All test data is based on UKAS-accredited tests and UKAS-accredited scope of testing.

 

Fire Performance - Non-Boundary Wall: 60,90,120 Minutes (E)

  • Test Reference - Internal: TR202200530-101415A


Fire Performance - Boundary Wall: 60,90 Minutes (EI)

  • Test Reference - Internal: TR202200530-101415A
  • Test Reference - External: TR20220722-004409A


MetWALL Perform Warranty

MetWALL Perform gives architects, developers and contractors reassurance when specifying through wall products on voestalpine Metsec steel frame systems.

This is an important addition to voestalpine Metsec’s framing range, providing warranted, UKAS-tested wall combinations, enabling clients to select the most cost-effective performance design solutions.

 

Metsec Decarb

voestalpine Metsec’s commitment to sustainable construction is emphasised by the introduction of responsibly sourced steel to their product ranges. Manufactured by processes which minimise carbon output by using state-of-the-art electric arc furnaces powered by renewable energy, rather than the traditional blast furnace which burn fossil fuels, Metsec Decarb promises to make a significant contribution towards reducing the carbon dioxide and carbon footprint of the building project.

 

System Codes

G1-N90-B22, G1-N100-B22, G1-N120-B22, G1-N150-B22, G1-N180-B22, G1-N200-B22, G1-N210-B22, G1-N240-B22, G1-N270-B22, G1-N300-B22, G1-N350-B22

-
-
Product certifications
-
-
Digital objects
-
-
Finish
Galvanized
-
-
Material
Steel, Plasterboard
-
-
Shape
Other
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-
Warranty description
30 year
-
-
SKU Code
G1-N90-B22, G1-N100-B22, G1-N120-B22, G1-N150-B22, G1-N180-B22, G1-N200-B22, G1-N210-B22, G1-N240-B22, G1-N270-B22, G1-N300-B22, G1-N350-B22
-
-

Specification

System performance
Structural design supervision and checking. Design of framing systems generally.
-
-
Framing members
Cold-formed galvanized steel sections.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By structural engineers design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Insulation
Not required., Insulation between framing.
-
-
Sheathing board
Klasse G-Board - 12 mm.
-
-
Framing
Metsec SFS 90 mm stud depth.
-
-
Inner layer
British Gypsum Fire Board, 12.5 mm.
-
-
Face layer
British Gypsum Fire Board, 12.5 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap / partition brace.
-
-
Internal face
90/ 120 minutes (insulation/ integrity).
-
-
External face
90/ 90 minutes (insulation/ integrity).
-
-
Fire performance
90 minutes (boundary wall); 120 minutes (non-boundary wall).
-
-
Thermal performance (U-value maximum)
Variable.
-
-
Air tightness
Variable.
-
-
Dimensional constraints
127 mm.
-
-

Sustainability data

Contains Red List materials
No
-
-
Country of product manufacture
United Kingdom
-
-
Material
Steel, Plasterboard
-
-
Recyclability
SFS Light Gauge Steel 95-100%
-
-
Recycled content
60 %
-
-