SFS infill wall with insulation and plasterboard lining.
Metsec SFS infill wall with British Gypsum Glasroc X sheathing board, Rockwool DuoSlab insulation, and British Gypsum Gyproc Fireline (2x12.5mm) or Wallboard (2x12.5mm) lining.
Resistance to Fire
voestalpine Metsec’s fire test data for infill walling is to BS EN 1364‑1:2015. All test data is based on UKAS-accredited tests and UKAS-accredited scope of testing.
2x12.5mm Fireline
Fire Performance - Non-Boundary Wall: 60,90,120 Minutes (E)
Fire Performance - Boundary Wall: 60,90 Minutes (EI)
2x12.5mm Wallboard
Fire Performance - Non-Boundary Wall: 60,90,120 Minutes (E)
Fire Performance - Boundary Wall: 60,90 Minutes (EI)
MetWALL Perform Warranty
MetWALL Perform gives architects, developers and contractors reassurance when specifying through wall products on voestalpine Metsec steel frame systems.
This is an important addition to voestalpine Metsec’s framing range, providing warranted, UKAS-tested wall combinations, enabling clients to select the most cost-effective performance design solutions.
Metsec Decarb
voestalpine Metsec’s commitment to sustainable construction is emphasised by the introduction of responsibly sourced steel to their product ranges. Manufactured by processes which minimise carbon output by using state-of-the-art electric arc furnaces powered by renewable energy, rather than the traditional blast furnace which burn fossil fuels, Metsec Decarb promises to make a significant contribution towards reducing the carbon dioxide and carbon footprint of the building project.
System Codes
DXXX-X1-N90-B20, DXXX-X1-N100-B20, DXXX-X1-N120-B20, DXXX-X1-N150-B20, DXXX-X1-N180-B20, DXXX-X1-N200-B20, DXXX-X1-N210-B20, DXXX-X1-N240-B20, DXXX-X1-N270-B20, DXXX-X1-N300-B20, DXXX-X1-N350-B20, DXXX-X1-N90-B22, DXXX-X1-N100-B22, DXXX-X1-N120-B22, DXXX-X1-N150-B22, DXXX-X1-N180-B22, DXXX-X1-N200-B22, DXXX-X1-N210-B22, DXXX-X1-N240-B22, DXXX-X1-N270-B22, DXXX-X1-N300-B22, DXXX-X1-N350-B22