NBS Source
I'm a manufacturer

Compare variants

Aluminium fire-resistant door - ADS 80 FR 60
Aluminium fire-resistant door - ADS 80 FR 60
Aluminium fire-resistant door - ADS 80 FR 60

Verified 1 month ago

Schueco UK Ltd

Verified 1 month ago

Schueco UK Ltd

Verified 1 month ago

Schueco UK Ltd
Summary
Door ADS 80 FR 60 for 60 minute fire resistance.
Digital objects
-
-
Finish
Anodized, Powder-coated
-
-
Material
Aluminium
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-

Specification

Standard
To EN 14351.
-
-
Configuration
Single leaf inward opening.
-
-
Doorset size
-
-
-
Performance
-
-
-
Fire performance
-
-
-
Fire integrity
To BS EN 1634-1, 60 minutes.
-
-
Fire insulation
To BS EN 1634-1, 60 minutes.
-
-
Radiation
To BS EN 1634-1, 60 minutes.
-
-
Smoke control
To BS EN 1634-1, Class Sa / S200.
-
-
Acoustic performance
-
-
-
Thermal
-
-
-
Intruder resistance
-
-
-
Minimum requirement
-
-
-
Frame
-
-
-
Material
Aluminium.
-
-
Finish
-
-
-
Coating
Polyester powder-coated., Anodized.
-
-
Texture
Manufacturer's standard.
-
-
Door leaf
-
-
-
Thickness
80 mm.
-
-
Core
Not applicable., Manufacturer's standard.
-
-
Panel details
Not applicable., Manufacturer's standard.
-
-
Material
Not applicable., Aluminium.
-
-
Glazing
-
-
-
Type
Not required., Required.
-
-
Finish
-
-
-
Coating
As Frame., Polyester powder-coated., Anodized.
-
-
Texture
Manufacturer's standard.
-
-
External colour
As Frame., Other.
-
-
Internal colour
As External., Other.
-
-
Film thickness (minimum)
Manufacturer's standard.
-
-

Additional properties

Durability
Up to 1 million cycles.
-
-
Load
To EN 1191, Class 5.
-
-
Watertightness
Not required.
-
-
Resistance to wind load
Not required.
-
-
Fittings
Fast push-in fixing of the fittings, fixing to the building structure, location of the intumescent strips.
-
-