Aluminium fire-resistant door - ADS 80 FR 30
Aluminium fire-resistant door - ADS 80 FR 30
Aluminium fire-resistant door - ADS 80 FR 30

Verified 2 months ago

Schueco UK Ltd

Verified 2 months ago

Schueco UK Ltd

Verified 2 months ago

Schueco UK Ltd
Summary
Door ADS 80 FR 30 for 30 minute fire resistance (Integrity & Insulation).
-
-
Application

Suitable for new build or renovation applications.

-
-
Description

Based on chamber hollow profiles with a basic depth of 80 mm, clear openings of up to 1400 x 2988 mm can be constructed.

In addition to fire and smoke protection properties, this series also has optional burglar resistance up to WK3 (RC 3), a combination of burglar-resistant WK2 (RC 2) and panic door, sound reduction (to 42 dB), access control and building regulation approved fixed glazing suitable for safety barrier loading. Concealed top door closers/ pre-selectors or door hinges can also be used.

Features and benefits:

  • Use of Schüco fire-resistant foam and fire-resistant joint sealing tape approved.
  • Locking cams pre-assembled at the factory allow uniform and flexible installation of all fittings components in the multipurpose groove.
  • Barrel hinges are easy for the fabricator to adjust.
  • Door versions without fireboards make for efficient fabrication.

Standards:

  • BS EN 14351.
  • BS EN 12211.
  • BS EN 1026.
  • BS EN 1027.
  • BS EN 12211.
  • BS EN 12046.
  • BS EN 1634/1364.
  • BS EN 1191.
  • BS EN 12400.
  • BS EN 13501-2
-
-
Digital objects
-
-
Color
Silver, Other
-
-
Finish
Anodized, Powder-coated
-
-
Material
Aluminium
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-

Specification

Classification data
Standard
To EN 14351-1.
-
-
Configuration
Fixed glazing.
-
-
Doorset size
-
-
-
Performance
-
-
-
Fire performance
-
-
-
Fire integrity
To BS EN 1634-1, 30 minutes.
-
-
Fire insulation
To BS EN 1634-1, 30 minutes.
-
-
Radiation
To BS EN 1634-1, 30 minutes.
-
-
Smoke control
To BS EN 1634-1, Class SA / S200.
-
-
Strength and durability
Mechanical strength: Class 2., Mechanical strength: Class 3., Mechanical strength: Class 4.
-
-
Thermal
-
-
-
Intruder resistance
-
-
-
Minimum requirement
-
-
-
Frame
-
-
-
Material
Aluminium.
-
-
Finish
-
-
-
Coating
Polyester powder-coated., Anodized.
-
-
Door leaf
-
-
-
Thickness
Not required.
-
-
Finish
-
-
-
Coating
As Frame., Polyester powder-coated., Anodized.
-
-
Texture
Manufacturer's standard.
-
-
External colour
As Frame., Other.
-
-
Internal colour
As External., Other.
-
-
Film thickness (minimum)
Manufacturer's standard.
-
-

Additional properties

Load
Not required.
-
-
Watertightness
To EN 1027, Class 4A.
-
-
Resistance to wind load
To EN 12211, C2/B2.
-
-
Fittings
Fast push-in fixing of the fittings, fixing to the building structure, location of the intumescent strips.
-
-

Sustainability data

Country of material origin
United Kingdom
-
-
Material
Aluminium
-
-