NBS Source
I'm a manufacturer

Compare variants

Metsec SFS infill wall with Knauf Windliner sheathing board, Knauf plasterboard, and Knauf Rocksilk RainScreen insulation
Metsec SFS infill wall with Knauf Windliner sheathing board, Knauf plasterboard, and Knauf Rocksilk RainScreen insulation
Metsec SFS infill wall with Knauf Windliner sheathing board, Knauf plasterboard, and Knauf Rocksilk RainScreen insulation

Verified 1 month ago

Metsec (voestalpine Metsec)

Verified 1 month ago

Metsec (voestalpine Metsec)

Verified 1 month ago

Metsec (voestalpine Metsec)
Summary
Metsec SFS infill wall with Knauf Windliner sheathing board, Knauf Rocksilk RainScreen insulation and Knauf Fire Panel (1x15mm) lining.
-
-
Application

SFS infill wall with insulation and plasterboard lining.

-
-
Description

Metsec SFS infill wall with Knauf Windliner sheathing board, Knauf Rocksilk RainScreen insulation and Knauf Fire Panel (1x15mm) lining.

 

Resistance to Fire

voestalpine Metsec’s fire test data for infill walling is to BS EN 1364‑1: 2015. All test data is based on unique UKAS accredited tests and UKAS accredited scope of testing.

 

Fire Performance - Non-Boundary Wall: 60 Minutes (E)

Test Reference - Internal: P100456-1127


MetWALL Perform Warranty

MetWALL Perform, an industry changing warranty giving architects, developers and contractors reassurance when specifying through wall products on voestalpine Metsec steel frame systems.

This is an important addition to voestalpine Metsec’s unique Framing range providing warranted, UKAS tested wall combinations, enabling clients to select the most cost-effective performance design solutions. 

 

Metsec Decarb

voestalpine Metsec’s commitment to sustainable construction is emphasised by the introduction of responsibly sourced steel to our product ranges. Manufactured by processes which minimise carbon output by using state-of-the-art electric arc furnaces powered by renewable energy, rather than the traditional blast furnace which burn fossil fuels, Metsec Decarb promises to make a significant contribution towards reducing the carbon dioxide and carbon footprint of the building project.

 

System Codes

EXXX-Z1-N90-K13, EXXX-Z1-N100-K13, EXXX-Z1-N120-K13, EXXX-Z1-N150-K13, EXXX-Z1-N180-K13, EXXX-Z1-N200-K13, EXXX-Z1-N210-K13, EXXX-Z1-N240-K13, EXXX-Z1-N270-K13, EXXX-Z1-N300-K13, EXXX-Z1-N350-K13

-
-
Product certifications
-
-
Digital objects
-
-
Finish
Galvanized
-
-
Material
Steel, Plasterboard
-
-
Shape
Other
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-
Warranty description
30 year
-
-
SKU Code
EXXX-Z1-N90-K13, EXXX-Z1-N100-K13, EXXX-Z1-N120-K13, EXXX-Z1-N150-K13, EXXX-Z1-N180-K13, EXXX-Z1-N200-K13, EXXX-Z1-N210-K13, EXXX-Z1-N240-K13, EXXX-Z1-N270-K13, EXXX-Z1-N300-K13, EXXX-Z1-N350-K13
-
-

Specification

System performance
Structural design supervision and checking. Design of framing systems generally.
-
-
Framing members
Cold-formed galvanized steel sections.
-
-
Connections
-
-
-
Connection fasteners
Self drilling tek screws.
-
-
Anchors to concrete and masonry
-
-
-
Type of anchor
By structural engineers design.
-
-
Movement joints
Deflection allowance at the top of the wall.
-
-

Additional properties

Insulation
External: Knauf Rocksilk; between framing: n/a., External: Knauf Rocksilk; between framing: ___.
-
-
Sheathing board
Knauf Windliner - 12.5 mm.
-
-
Framing
Metsec SFS 90 mm stud depth.
-
-
Face layer
Knauf Fire Board, 15 mm.
-
-
Fasteners
Drywall screws.
-
-
System accessories
Flatstrap / partition brace.
-
-
Internal face
60/ 60 minutes (insulation/ integrity).
-
-
External face
0/ 0 minutes (insulation/ integrity).
-
-
Fire performance
0 minutes (boundary wall); 60 minutes (non-boundary wall).
-
-
Thermal performance (U-value maximum)
Variable.
-
-
Air tightness
Variable.
-
-
Dimensional constraints
Variable.
-
-

Sustainability data

Contains Red List materials
No
-
-
Country of product manufacture
United Kingdom
-
-
Material
Steel, Plasterboard
-
-
Recyclability
SFS Light Gauge Steel 95-100%
-
-
Recycled content
60 %
-
-