NBS Source
I'm a manufacturer

Compare variants

Jansen-Economy 60 Fire Protection Door
Jansen-Economy 60 Fire Protection Door
Jansen-Economy 60 Fire Protection Door

Verified 5 months ago

Minimal Frame Projects

Verified 5 months ago

Minimal Frame Projects

Verified 5 months ago

Minimal Frame Projects
Summary
Slimline steel door with fire protection class E30/EW30/E60/EW60, available in a range of sizes and finishes.
-
-
Application

Suitable for all applications that require large E30/EW30/E60/EW60 smoke/fire closures with a slimline look.

-
-
Description

With the well-known Jansen Economy profiles class E30/EW30/E60/EW60 fire doors and fixed lights up to class E90 can be fitted. The appearance of the Jansen Economy doors is identical with that of the Janisol 2 and Janisol C4 fire safety systems. The profiles of the 60 depth have very narrow face widths.

Jansen Economy profiles allow smoke protection system components with cost-effective flush smoke protection doors complying with DIN 18095. A variety of doors with different designs and functions have been tested and approved.

Features and benefits:

  • Dry glazing and glazing with putty.
  • Central glazed panel.
  • Connection to solid wall or lightweight wall construction.
  • Door height up to 3.8 m with single-latch lock possible.
  • Fire resistance class E30/EW30/E60/EW60.

Standards:

  • Fire resistance class E30/EW30/E60/EW60.
  • Smoke control in accordance with DIN 18095.
  • Smoke control tested in accordance with EN 1634-3.
  • Durability (C5) tested in accordance with EN 1191.
  • Emergency exit door in accordance with EN 1125 / EN 179.
-
-
Finish
Natural, Galvanized, Powder-coated
-
-
Material
Glass, Steel
-
-
Shape
Rectangle, Square
-
-
Height
Bespoke
-
-

Specification

Configuration
Single-leaf door.
-
-
Performance
-
-
-
Fire resistance
-
-
-
Integrity
To EN 1634-1 and EN 13501-2, E60/ EW60., To EN 1634-1 and EN 13501-2, E30/ EW30.
-
-
Radiation
To EN 1634-1 and EN 13501-2, E60/ EW60., To EN 1634-1 and EN 13501-2, E30/ EW30.
-
-
Smoke leakage
To EN 1634-3 and DIN 18095, Sa/S200.
-
-
Acoustic performance
To EN ISO 10140, up to Rw 44 dB.
-
-
Strength and durability
To EN 1192, Class 4., To EN 1191 and EN 1603, Class 8.
-
-
Thermal
To EN ISO 10077-2, from 5.65 W/m²K.
-
-
Bullet resistance
To EN 1522, Class FB6.
-
-
Frame
-
-
-
Material
Steel.
-
-
Finish
-
-
-
Coating
Not applicable., Strip-galvanized., Powder-coated., Stove-enamelled.
-
-

Additional properties

Burglar resistance
To EN 1627, RC3.
-
-
Watertightness
To EN 12208, Class 4A.
-
-
Wind load resistance
To EN 12210, Class 4.
-
-
SelfClosing
true
-
-
Operating forces
To EN 13115 and EN 12217, Class 2.
-
-

Sustainability data

Material
Glass, Steel
-
-