NBS Source
I'm a manufacturer

Compare variants

SnapLoc Standing Seam Wall Cladding System - APL SnapLoc™  - Traditional Standing Seam Cladding
SnapLoc Standing Seam Wall Cladding System - APL SnapLoc™  - Traditional Standing Seam Cladding

Verified 3 months ago

Architectural Profiles Ltd

Vertical Steel Profiled Sheets

Verified 3 months ago

Architectural Profiles Ltd

Vertical Aluminium Profiled Sheets

Summary
Traditional standing-seam cladding.
Traditional standing-seam cladding.
Third party certification
Color
Silver, Other
Silver, Other
Finish
Embossed, Painted, Natural
Embossed, Painted, Natural
Material
Aluminium, Steel
Aluminium, Steel
Shape
Other
Other
Length
Bespoke
Bespoke
Width
Bespoke
Bespoke
Height
40 mm
40 mm
Warranty description
25 year
25 year

Specification

Liner sheets
-
-
Material
Not required., AP19 LPH profile in 0.4 mm steel in off-white 80F - solid., APL StrongBak™.
Not required., AP19 LPH profile in 0.4 mm steel in off-white 80F - solid., APL StrongBak™.
Primary fasteners
APL P191/HH fixing range.
APL P191/HH fixing range.
End and side laps
Minimum 75 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT sidelap sealant range, P152 Flute Fillers.
Minimum 75 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT sidelap sealant range, P152 Flute Fillers.
Air and vapour control layer
-
-
Material
AP19 LPH Liner sheet., APL StrongBak™., Other.
AP19 LPH Liner sheet., APL StrongBak™., Other.
Fasteners
APL P191/HH fixing range., Other.
APL P191/HH fixing range., Other.
Sealing
APL P191/HH fixing range (side laps sealed with two runs of P108/VCT)., Other.
APL P191/HH fixing range (side laps sealed with two runs of P108/VCT)., Other.
Spacers
Tritherm Spacer System℗ - Fully-Filled Cavity.
Tritherm Spacer System℗ - Fully-Filled Cavity.
Acoustic insulation
A1-rated with thickness and performance specification as required to meet performance.
A1-rated with thickness and performance specification as required to meet performance.
Thermal insulation
Between liner/ sheathing board and decking profile: A1-rated, thickness as required to meet U-value requirement., Above decking profile/ above OSB - 30 mm Rockwool RW5.
Between liner/ sheathing board and decking profile: A1-rated, thickness as required to meet U-value requirement., Above decking profile/ above OSB - 30 mm Rockwool RW5.
External sheets
-
-
Material
APL SnapLoc™ 40 / module width - steel.
APL SnapLoc™ 40 / module width - aluminium.
Primary fasteners
APL 191/LP fixing range at top of each sheet; decking sheet with APL P191/HH fixing range in each corrugation to APZ; P719 tribar fixed at max 200 mm crs to decking profile; P716 cleat fixed with P191/CSK range with three per cleat.
APL 191/LP fixing range at top of each sheet; decking sheet with APL P191/HH fixing range in each corrugation to APZ; P719 tribar fixed at max 200 mm crs to decking profile; P716 cleat fixed with P191/CSK range with three per cleat.
Wall glazing
Required., Not required.
Required., Not required.
System accessories
APL System Flashings., APL Fixings (P191 & P192)., APL Sealants and P152 profile flute fillers as APL recommendations and to match profiles., P744 "Snapper" for installation on SnapLoc profile., Verge closer with P152 filler block on P103/SB6 expanding foam tape.
APL System Flashings., APL Fixings (P191 & P192)., APL Sealants and P152 profile flute fillers as APL recommendations and to match profiles., P744 "Snapper" for installation on SnapLoc profile., Verge closer with P152 filler block on P103/SB6 expanding foam tape.

Additional properties

Liner Supports
-
-
Support
For decking profile onto steel cladding rails - P157 HHBs Generally not exceeding 1500 mm max c/c., For decking profile onto SFS / Blockwork - P618 tophats & P157 HHBs generally not exceeding 1200 mm max c/c., For SnapLoc profile onto APL decking profile - Tribar fixed to APL decking profile at max 600 mm crs and and at each end of each sheet.
For decking profile onto steel cladding rails - P157 HHBs Generally not exceeding 1500 mm max c/c., For decking profile onto SFS / Blockwork - P618 tophats & P157 HHBs generally not exceeding 1200 mm max c/c., For SnapLoc profile onto APL decking profile - Tribar fixed to APL decking profile at max 600 mm crs and and at each end of each sheet.
Fixings
APL P191/HH + P191/LP + P191/CSK fixing range as required for components including P716 cleat to Tribar at max 400 mm crs and each end of each SnapLoc sheet; For RW3 insulation, use one P534/SL washer with P191/CSK fixing per board.
APL P191/HH + P191/LP + P191/CSK fixing range as required for components including P716 cleat to Tribar at max 400 mm crs and each end of each SnapLoc sheet; For RW3 insulation, use one P534/SL washer with P191/CSK fixing per board.
Colour/ Finish:
APL PUF., Colorcoat® PRISMA, LeatherGrain Plastisol, Natural Galvanized Steel.
Armacoil™ HDP., Stucco-Embossed Mill-Finish (SEMF)., Smooth Mill Finish (MF)., SnapLoc™Aluminium-ZINC.
NominalThickness
0.7 mm.
0.9 mm.
Minimum bearing area
50 mm for decking profile.
50 mm for decking profile.
Recycled content (minimum)
85%.
Up to 95%.

Sustainability data

Contains Red List materials
No
No
Country of material origin
United Kingdom
United Kingdom
Country of product manufacture
United Kingdom
United Kingdom
Recyclability
High
High
Recycled content
%
%