NBS Source
I'm a manufacturer

Compare variants

Verified 3 months ago

Metsec (voestalpine Metsec)

SS70-B-60(25)

Verified 3 months ago

Metsec (voestalpine Metsec)

SS60-B-60(25)

Verified 3 months ago

Metsec (voestalpine Metsec)

SS92-B-60(50)

Summary
Plasterboard stud partition system.
Plasterboard stud partition system.
Plasterboard stud partition system.
Third party certification
Length
Bespoke
Bespoke
Bespoke
Width
132 mm, 154 mm, 208 mm
132 mm, 154 mm, 208 mm
132 mm, 154 mm, 208 mm
Height
Bespoke
Bespoke
Bespoke

Specification

Framing
Staggered Speedline 'I' Stud, 70 mm.
Staggered Speedline 'I' Stud, 60 mm.
Staggered Speedline 'I' Stud, 92 mm.
Insulation
Acoustic partition roll, 25 mm.
Acoustic partition roll, 25 mm.
Acoustic partition roll, 50 mm.
Linings
-
-
-
Inner layers
British Gypsum Gyproc SoundBloc, 15 mm.
British Gypsum Gyproc SoundBloc, 15 mm.
British Gypsum Gyproc SoundBloc, 15 mm.
Outer layers
British Gypsum Gyproc SoundBloc, 15 mm.
British Gypsum Gyproc SoundBloc, 15 mm.
British Gypsum Gyproc SoundBloc, 15 mm.
Fasteners
Speedline Drywall Screws.
Speedline Drywall Screws.
Speedline Drywall Screws.
Joint treatment
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
System accessories
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.

Additional properties

Fire resistance
To BS 476:1987:Part 22, 90/ 90 minutes (Integrity/ Insulation).
To BS 476:1987:Part 22, 90/ 90 minutes (Integrity/ Insulation).
To BS 476:1987:Part 22, 90/ 90 minutes (Integrity/ Insulation).
Partition height
-
-
-
Nominal thickness
154 mm.
132 mm.
208 mm.
Calculated weighted sound reduction index (Rw)
58 Rw dB (-8).
58 Rw dB (-8).
61 Rw dB (-6).
Centres
300 mm (staggered).
300 mm (staggered).
300 mm (staggered).
StrengthGrade
Severe duty.
Severe duty.
Severe duty.
Head/ Floor channel
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
Standards
To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.
To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.
To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.