SPEEDLINE Twin Frame Braced C Stud Partition Systems Utilising British Gypsum Board
SPEEDLINE Twin Frame Braced C Stud Partition Systems Utilising British Gypsum Board
SPEEDLINE Twin Frame Braced C Stud Partition Systems Utilising British Gypsum Board

Verified 2 months ago

Metsec (voestalpine Metsec)

Verified 2 months ago

Metsec (voestalpine Metsec)

Verified 2 months ago

Metsec (voestalpine Metsec)
Summary
Plasterboard partition system.
Third party certification
Length
Bespoke
-
-
Width
200 mm, 240 mm, 250 mm
-
-
Height
Bespoke
-
-

Specification

Framing
Twin Speedline 'C' Stud, braced, 50 mm.
-
-
Insulation
Acoustic partition roll, 50+50 mm.
-
-
Linings
-
-
-
Inner layers
British Gypsum Gyproc SoundBloc, 12.5 mm.
-
-
Outer layers
British Gypsum Gyproc SoundBloc, 12.5 mm.
-
-
Fasteners
Speedline Drywall Screws.
-
-
Joint treatment
Speedline Drywall Fibreglass Tape., Speedline Ready Mix Joint Compound., Speedline Corner Bead Tape.
-
-
System accessories
Speedline Fire Rated Acoustic Sealant., Speedline PB24 Partition Brace., Speedline FS24 Flat Bracing Strip., Speedline Service Support Plate., Speedline Putty Pads.
-
-

Additional properties

Fire resistance
To BS 476-22:1987, 60/ 60 minutes (Integrity/ Insulation).
-
-
Nominal thickness
240 mm.
-
-
Calculated weighted sound reduction index (Rw)
63 (-3;-9) Rw dB.
-
-
Centres
600 mm.
-
-
StrengthGrade
Severe duty.
-
-
Head/ Floor channel
Speedline Standard Track., Speedline 32 mm Leg Track., Speedline Deep Track., Speedline Extra Deep Track.
-
-
Standards
To BS 5234-2:1992 Annexes A-F; BS 476:1987:Part 22; BS EN ISO 10140-2: 2010.
-
-