NBS Source
I'm a manufacturer

Compare variants

CU4 -  Rectangular EIS 4Hours Fire Damper - Fire Damper
CU4 -  Rectangular EIS 4Hours Fire Damper - Fire Damper

Verified 1 month ago

Rf-Technologies

CU4L fire damper

Verified 1 month ago

Rf-Technologies

CU4 fire damper

Summary
Rectangular EIS fire damper for duct sizes up to W1200 x H800 mm, UKCA/CE certified, with a fire resistance up to 240 minutes in rigid walls, both for motorized and non-motorized applications.
Rectangular EIS fire damper for duct sizes up to W1200 x H800 mm, UKCA/CE certified, with a fire resistance up to 240 minutes in rigid walls, both for motorized and non-motorized applications.
Third party certification
Digital objects
Color
White
White
Material
Calcium silicate
Calcium silicate
Shape
Rectangle, Square
Rectangle, Square
Length
400 mm, Bespoke
400 mm, Bespoke
Width
200 mm, 250 mm, 300 mm, 350 mm, 400 mm, 450 mm, 500 mm, 550 mm, 600 mm, 650 mm, 700 mm, 750 mm, 800 mm, 850 mm, 900 mm, 950 mm, 1000 mm, 1050 mm, 1100 mm, 1150 mm, 1200 mm, Bespoke
200 mm, 250 mm, 300 mm, 350 mm, 400 mm, 450 mm, 500 mm, 550 mm, 600 mm, 650 mm, 700 mm, 750 mm, 800 mm, 850 mm, 900 mm, 950 mm, 1000 mm, 1050 mm, 1100 mm, 1150 mm, 1200 mm, Bespoke
Height
200 mm, 250 mm, 300 mm, 350 mm, 400 mm, 450 mm, 500 mm, 550 mm, 600 mm, 650 mm, 700 mm, 750 mm, 800 mm, Bespoke
200 mm, 250 mm, 300 mm, 350 mm, 400 mm, 450 mm, 500 mm, 550 mm, 600 mm, 650 mm, 700 mm, 750 mm, 800 mm, Bespoke
Warranty description
One year
One year

Specification

Standard
-
-
Fire dampers
To EN 15650:2010.
To EN 15650:2010.
Test
To EN 1366-2, up to 500 Pa.
To EN 1366-2, up to 500 Pa.
Classification
To EN 13501-3.
To EN 13501-3.
Arrangement
Single-blade.
Single-blade.
Classification
-
-
Material
Tunnel casing: Calcium silicate.
Tunnel casing: Calcium silicate.
Accessories
PG20 connection to ducts with 20 mm flanges., PG40 connection to ducts with 40 mm flanges., PM connection to ducts by insertion., PP flange - no connection., PRJ circular connection., PPT grill., Limit switch (open/closed)., Additional limit switch (open/closed)., None.
PG20 connection to ducts with 20 mm flanges., PG40 connection to ducts with 40 mm flanges., PM connection to ducts by insertion., PP flange - no connection., Limit switch (open/closed)., Additional limit switch (open/closed)., None.
Fusible links
-
-
Fusing temperature
72°C.
72°C.

Additional properties

Dimensions
-
-
Integral accessories
PG30 connection to ducts with 30 mm flanges.
Tunnel casing extension.
PG30 connection to ducts with 30 mm flanges.
Third-party certification
UKCA marked 2822-UKCA-CPR-0059.
CE Marked BCCA-0749-CPR- BC1-606-0464-15650.04-0464&2517.
NF537 marked 18.22
UKCA marked 2822-UKCA-CPR-0059.
CE Marked BCCA-0749-CPR- BC1-606-0464-15650.04-0464&2517.
NF537 marked 18.22
Air tightness
Class B., Class C.
Class B., Class C.
Thermal release mechanism
Actuator - ONE T 24 V., Actuator - ONE T 230 V., Actuator - ONE-X 24 V., Actuator - ONE-X 230 V., Actuator - Belimo 24 V., Actuator - Belimo 230 V., Fusible link mechanism.
Actuator - ONE T 24 V., Actuator - ONE T 230 V., Actuator - ONE-X 24 V., Actuator - ONE-X 230 V., Actuator - Belimo 24 V., Actuator - Belimo 230 V., Fusible link mechanism.

Sustainability data

Country of material origin
Europe
Europe
Country of product manufacture
Belgium
Belgium
Material
Calcium silicate
Calcium silicate