Aluminium fire-resistant door - ADS 80 FR 60
Aluminium fire-resistant door - ADS 80 FR 60
Aluminium fire-resistant door - ADS 80 FR 60

Verified 2 months ago

Schueco UK Ltd

Verified 2 months ago

Schueco UK Ltd

Verified 2 months ago

Schueco UK Ltd
Summary
Door ADS 80 FR 60 for 60 minute fire resistance (Integrity & Insulation).
-
-
Application

Suitable for new build or renovation applications.

-
-
Description

Based on stable 5-chamber hollow profiles with a basic depth of 80 mm, clear openings of up to 1400 x 2488 mm can be constructed.

In addition to fire and smoke protection properties, this series also has optional burglar resistance to WK2 (RC 2), noise reduction (up to 42 dB), access control and building regulation approved fixed glazing suitable for safety barrier loading. Concealed top door closers/ pre-selectors or door hinges can also be used.

Features and benefits:

  • Use of Schüco fire-resistant foam and fire-resistant joint sealing tape approved.
  • Locking cams pre-assembled at the factory allow uniform and flexible installation of all fittings components in the multipurpose groove.
  • Barrel hinges are easy for the fabricator to adjust.
  • Door versions without fireboards make for efficient fabrication.

Standards:

  • BS EN 14351.
  • BS EN 12211.
  • BS EN 1026.
  • BS EN 1027.
  • BS EN 12211.
  • BS EN 12046.
  • BS EN 1634/1364.
  • BS EN 1191.
  • BS EN 12400.
  • BS EN 13501-2
-
-
Digital objects
-
-
Finish
Anodized, Powder-coated
-
-
Material
Aluminium
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-

Specification

Classification data
Standard
To EN 14351.
-
-
Configuration
Single leaf inward opening.
-
-
Doorset size
-
-
-
Performance
-
-
-
Fire performance
-
-
-
Fire integrity
To BS EN 1634-1, 60 minutes.
-
-
Fire insulation
To BS EN 1634-1, 60 minutes.
-
-
Radiation
To BS EN 1634-1, 60 minutes.
-
-
Smoke control
To BS EN 1634-1, Class Sa / S200.
-
-
Acoustic performance
-
-
-
Thermal
-
-
-
Intruder resistance
-
-
-
Minimum requirement
-
-
-
Frame
-
-
-
Material
Aluminium.
-
-
Finish
-
-
-
Coating
Polyester powder-coated., Anodized.
-
-
Texture
Manufacturer's standard.
-
-
Door leaf
-
-
-
Thickness
80 mm.
-
-
Core
Not applicable., Manufacturer's standard.
-
-
Panel details
Not applicable., Manufacturer's standard.
-
-
Material
Not applicable., Aluminium.
-
-
Glazing
-
-
-
Type
Not required., Required.
-
-
Finish
-
-
-
Coating
As Frame., Polyester powder-coated., Anodized.
-
-
Texture
Manufacturer's standard.
-
-
External colour
As Frame., Other.
-
-
Internal colour
As External., Other.
-
-
Film thickness (minimum)
Manufacturer's standard.
-
-

Additional properties

Durability
Up to 1 million cycles.
-
-
Load
To EN 1191, Class 5.
-
-
Watertightness
Not required.
-
-
Resistance to wind load
Not required.
-
-
Fittings
Fast push-in fixing of the fittings, fixing to the building structure, location of the intumescent strips.
-
-

Sustainability data

Material
Aluminium
-
-