1-Hour Fire Rated Metal Access Panels

Verified by manufacturer 6 months ago

APC150X150CR (150 x 150 mm)

Timloc Building Products Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • Warringtonfire

    Warringtonfire

    Certificate type

Multi-performance, one-hour fire-rated steel access panels with mineral wool and draught stripping.

Jump to:
+44 (0)1405 765567 Website

Application

  • Access to services and connections to voids behind dry lined walls, ducts or ceilings where a one-hour fire rating is required.
  • Projects with additional reduced air leakage and /or acoustic performance requirements.
  • Solution for meeting Part J and the gas safety industry’s concealed boiler flue inspection access requirements (one-hour fire rated applications).

Description

Multi-performance, one-hour fire-rated steel access panels with mineral wool and draught stripping.


Features and benefits:

  • Purpose-made product, saves time and money compared with traditional joiner–made access doors.
  • Independently tested fire rating.
  • Mineral wool insulation and draught stripped to reduce the opportunity of air leakage in application.
  • 32 mm, low-profile frame, suitable for installation with 15 mm plaster board.
  • Flush-fitting door panels with excellent aesthetic appearance and finish.
  • Visible picture frame surround smartly conceals cut out edges and contributes to a faster installation.
  • Enduring polyester powder coated finish.
  • Can be painted.
  • Quick and straightforward to install.
  • Universal door handing.
  • Hinged door panel with T-key lock mechanism and key lock
  • Quick release door panel mechanism fully removes to the door for maximum access.
  • Acoustic performance of 33 dB; consult manufacturer for further details).


Quality:

  • Manufactured to BS EN ISO 9001 and BS EN ISO 14001.
  • Helping to meet Building Regulation:
  1. Document Part J – Concealed Flues in Voids (2010 edition).
  2. Document Part E – Resistant to Sound (2003 edition)
  3. Part L1 and L2 – Conservation of Fuel and Power (2013 edition).

General information

Color

White

Guidance for specification option:

RAL 9016.

Finish

Smooth

Guidance for specification option:

20% gloss.

Material

Steel

Glass mineral wool

Shape

Square

Rectangle

Uniclass

Pr_30_59_36_01 Access panelsPrimary

CAWS

K10/57 Encasement on timber framing

K10/55 Encasement system (metal framing)

K10/41 Wall lining system (metal furrings)

K10/35 Wall lining system (metal framing)

K10/45 Wall lining system (adhesive)

K10/50 Suspended ceiling system on metal framing

K10/15 Lining on timber

K10/30 Metal stud

K10/25 Ceiling lining on timber

K10/430 Access panels

Specification data - Access panels

Fire performance

-

Fire resistance

60 minutes.

Position

Ceiling-mounted.

Duct-mounted.

Wall-mounted.

Size

150 x 150 mm.

Guidance for specification option:

Frame fitting size: 155 x 155 mm.

Clear opening size: 110 x 110 mm.

Overall panel and frame size: 200 x 200 mm.

Frame

Exposed picture frame type.

Panel

-

Material

Steel with glass wool insulation.

Guidance for specification option:

Insulation: 45 kg/m³.

Integral finish

Powder-coated, white.

Guidance for specification option:

RAL 9016, matt (20% gloss).

Latch or lock type

T-key lock.

Operation

Hinged.

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Certificate

Warringtonfire

Warringtonfire

509889A Review of Fire Test Report 309752A for APC Metal 1 Hour Fire-Rated Access Panels

Warringtonfire

Warringtonfire

Fire Test Report 309752A for APC Metal 1 Hour Fire-Rated Access Panels

Literature

Timloc Building Products Metal Fire Rated Access Panels Datasheet

Timloc Building Products Metal Fire Rated Access Panels Datasheet