NBS Source
I'm a manufacturer

83702 E-Cylinder with Turn

Verified by manufacturer 3 months ago

Glutz UK Ltd

Battery-powered electronic cylinder for internal and external doors.

Jump to:
+44 (0)1376 348808 Website

Application

For internal and external doors.

Description

Battery-powered electronic cylinder for internal and external doors. Opening and closing from both sides is done by contactless reading of the RFID medium or by the smartphone app and subsequent turning of the knob. Note: PT1 (drill protection) version only applicable for the external side.


Scope of supply:

  • 1 E cylinder.
  • 1 battery.
  • 1 retaining screw M5x75.
  • 1 Quick Guide.


Features and benefits:

  • Exterior E-knob with access control function and battery.
  • Interior with mechanical thumbturn.
  • Identification via RFID Mifare DESfire EV1/2 (ISO 14443A).
  • Programming via media, wireless access (868 MHz).
  • Protection classes: IP56, EN 15684, RC2.
  • Fire protection EN 1634-2: 90 minutes.
  • BLE-ready
  • Optional high exterior drill protection (PT1), up to RC4 (with corresponding door plate), low temperature (LT) for operation below 0°C and shortened rib side A by 8 mm (ST8), for protection fittings with plug-pulling protection.


General information

Color

Black

Bronze

Silver

Finish

Matt

Polished

Chrome

Shape

Other

Length

50 mm

220 mm

Manufacturer guidance

Total length: minimum 50 mm, maximum 220 mm.

Width

35.9 mm

Height

34.3 mm

Uniclass

Pr_30_36_08_24 Door latchesPrimary

CAWS

P21/530 Special function door locks

P21/26 Special function door locks

Specification data - Door latches

Standard

To EN 15684.

Latch or lock type

Electronic cylinder.

Material and finish

Matt nickel.

Polished chrome.

Matt chrome.

Black.

Bronze effect.

Length

Guidance for specification option:

  • Lengths: Refer to the length matrix for available combinations of external and internal lengths, and insert requirements.
  • Total length: minimum 50 mm, maximum 220 mm.

Operating temperature

Standard.

Low temperature (LT).

Guidance for specification option:

For operation below 0°C.

Security

Standard.

PT1.

Guidance for specification option:

  • High exterior drill protection (PT1), up to RC4 (with corresponding door plate).
  • PT1 (drill protection) version only applicable for the external side.

ST8.

Guidance for specification option:

Shortened rib side A by 8 mm (ST8), for protection fittings with plug-pulling protection.

Turn-handle

Glutz knob.

Blind.

Type

Standard.

Cog 10.

Antenna cover

Black.

White.

RFID credentials

RFID Mifare DESfire EV1/2 (ISO 14443A).

Fire resistance

To EN 1634-2, 90 minutes.

Ingress protection (IP) rating

IP56.