Verified by manufacturer 11 days ago
Constructionline Gold
Certificate type
ISO 9001 Quality Management
Certificate type
smas WORKSAFE
Certificate type
Warringtonfire
Certificate type
IFCC
Certificate type
CE marked Fire shutter with 60 minutes for end use steel, masonry, timber/stud. Fire tested to BS EN 1634-1 on stud system. European Standards BS EN 16034 and BS EN 13241-2. Internal tubular motor.
Suitable for installation within the following structures:
Designed for multiple applications, including compartmentation and openings in walls. Regularly used in hospitals, schools, hotels, high buildings, mixed use, offices, military sites, retail, stadia, museums and galleries, prison and policing sector, industrial and utility applications, transport infrastructure and many others.
The fire shutters are manufactured and produced in accordance with the parameters and technical aspects indicated within the specifications, which were submitted to the Warrington Fire Research Establishment. The shutters are constructed for fire testing in accordance with BS EN 1634-1 and in full compliance with the fire standard BS EN 16034:2014. This product can be fitted to either a flexible or rigid structure and is CE marked. As well as a tested and certified fire rating, this product will act as a security barrier when in its closed position. Third party Installation Certification is with IFC (certificate 3425) for the installation of fire shutters.
Features and benefits:
Endplates:
The endplates are fixed to a steel fixing angle which spans the full height of the shutter, which in turn is fixed back to the wall construction. Accordingly, the angles are slotted for expansion with an anchor point located at the bottom of the angle.
Guides:
Vary from 50 mm straight channel galvanized guide mounted on 75 x 50 mm carbon steel angle (minimum). For shutters of increased width compared to tested sizes A1 Shutters provide for expansion and the depth of each guide rail shall be increased dependent on the shutter width.
Hood:
Formed from 20 swg steel sheet, with the top leg slotted for expansion. Dependent on the fire rating of the shutter (one hour only) and the size of the opening.
Release mechanism:
Fire relay linked to the fire alarm to allow closure from a fire alarm signal comes complete with a battery backup (mandatory). The fire relay and battery backup are tested as part of the ability to release and durability tests. Alternatively, audio visuals are available, again to be linked to the fire alarm, this unit offers the facility of a time delay, this flashes and sounds to warn that the fire shutter is closing.
Color | Manufacturer guidanceBS 4800 and RAL colours available. |
Finish | Galvanized Powder-coated |
Material | Steel |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | One year |
Uniclass | |
CAWS | L20/610 Roller shutters/ curtains |
Standard | Fire tested to BS EN 1634-1. Harmonised product standard BS EN 16034 and BS EN 13241-2. |
Opening sizes | Manufacturer guidanceMaximum size (w x h): 4000 x 3800 mm. |
Format | Fire shutter. |
Arrangement | Rectangular, single vertical system.Guidance for specification option: Up to five metres wide with a maximum drop height of three metres. |
Performance | |
Fire performance | |
Fire resistance | 60 minutes. |
Smoke leakage | Manufacturer guidanceNo smoke leakage available with a shutter system. If required please see A1S Group Flameshield fire and smoke curtain range. |
Watertightness | Manufacturer guidanceNo performance declared. For internal use only. |
Acoustic performance | Unrated. |
Frame and guides | |
Material | Steel. |
Finish | Polyester powder-coating.Guidance for specification option: Angles, barrel and end plates are painted. Galvanized.Guidance for specification option: Guides. |
Colour | BS 4800.RAL.Manufacturer guidanceSubject to availability. Consult manufacturer for details and insert requirements. |
Shutter curtain | |
Lath material | 76 mm curved steel scroll laths interlocked with steel end locks and galvanized 'T' section bottom rail. |
Profile | Curved. |
Finish and colour | Galvanized.BS 4800.Guidance for specification option: Polyester powder coating. RAL.Guidance for specification option: Polyester powder coating. |
Operation | Electrically operated 1PH tubular motor. |
Accessories | Audio/ visual device. Guidance for specification option: Audio Visuals are available, again to be linked to the fire alarm, this unit offers the facility of a time delay, this flashes and sounds to warn that the fire shutter is closing. Relay. Key Switch. Battery Back UP (BBU). |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
Constructionline Gold
Constructionline Gold
ISO 9001 Quality Management
ISO 9001 2015 (Issue 5)
smas WORKSAFE
SMAS 2023 (SSIP)
Warringtonfire
Certificate of Constancy of Performance (AVCP) CE marked fire shutters 60-240 minutes
IFCC
IFC Third Party Installation, Commissioning and Servicing Fire Shutters SDI 17