Verified by manufacturer 8 months ago
Stick-frame curtain wall system.
A stick curtain wall system suitable for vertical and sloped applications, including facetted walls, up to ten storeys high. Applications include:
The AA®110 Stick Curtain Wall system is available in a variety of cap designs and is suitable for vertical and sloped applications, including facetted walls. To provide complete design flexibility, the system is also available horizontally or vertically capped, as a Structurally Silicone Glazed system and a Fire Resistant system.
The flexibility of design allows every project need to be met without compromising the performance of the façade. This is achievable through a variety of standard depth mullion, transom, thermal break and gasket options. It is Kawneer's most recommended curtain wall system up to ten storeys – over this, it is recommend that the specifier looks into the benefits of a unitized approach requiring less external access to the building’s façade.
Features and benefits:
Color | Beige Black Blue Bronze Brown Manufacturer guidanceInsert requirements. |
Finish | Powder-coated Guidance for specification option: Permacover polyester powder-coated to BS 6495. Anodized |
Material | Aluminium |
Shape | Square Circle Triangle Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H11/110 Curtain walling |
Framing | |
Frame members | Aluminium curtain wall frame sections. |
Cladding units | |
Glass units | Guidance for specification option: 4—50 mm glazing thickness. Structurally silicone-glazed can accommodate 26—37 mm infill. |
Panels and facings | |
Material | Aluminium infill panels. |
Execution | Curtain wall assembly and erection. |
Type | Fully capped and pressure-plated system. Fully structurally silicone-glazed. Horizontally capped/ vertically silicone-glazed/ rubberized pressure plate. Vertically capped/ horizontally silicone-glazed/ rubberized pressure plate. |
Drainage | Mullion. Guidance for specification option: Zone drainage systems feature simple butt-jointed mullions and transoms, with each panel acting as an individual unit. Drainage and ventilation slots are located in the vertical pressure plate. Transoms are square-cut at the ends to incorporate EPDM mouldings and gaskets to maintain each zone. Transoms are fitted with a ‘Batman gasket’ to maintain the thermal performance. Each panel is individually pressure-equalized and drained via its transom, enabling the curtain wall to quickly react to fluctuating wind pressure. Zone. Guidance for specification option: Zone drainage systems feature simple butt-jointed mullions and transoms, with each panel acting as an individual unit. Drainage and ventilation slots are located in the vertical pressure plate. Transoms are square-cut at the ends to incorporate EPDM mouldings and gaskets to maintain each zone. Transoms are fitted with a ‘Batman gasket’ to maintain the thermal performance. Each panel is individually pressure-equalized and drained via its transom, enabling the curtain wall to quickly react to fluctuating wind pressure. |
Internal | Guidance for specification option: Insert requirements. Manufacturer guidanceColour. |
External | Guidance for specification option: Insert requirements. Manufacturer guidanceColour. |
Surface finish | Permacover anodized to BS 3987. Permacover polyester powder-coated to BS 6495. |
Weather performance | To BS 6375-1. |
Air permeability | To BS EN 12207, Class 4 (600 Pa). |
Watertightness | To BS EN 12208, Class 9a (600 Pa). |
Wind resistance | 2400 Pa; 3600 Pa. Guidance for specification option: Serviceability; safety. |
Film thickness | 40 micrometres. 60 micrometres. 80 micrometres. |
Recyclability | 100% |
Platform | Compatible | Version |
---|---|---|
- | 1 |