ACS Apollo II Reinforcement

Verified by manufacturer 1 month ago

ACS Apollo 2 ATS50 Masonry Reinforcement

ACS Stainless Steel Fixings Ltd Variant:
Third party certifications:
  • DoP

    DoP

    Certificate type

Masonry reinforcement.

Jump to:
+44 (0)113 391 8200 Website

Application

Ladder‐type steel meshwork for use as bed‐joint reinforcement in masonry constructions.

Description

Apollo II is a certified and tested bed joint reinforcement product, designed specifically to increase the flexural and tensile strength of masonry walls.


Manufactured in stainless steel, this high-quality solution allows for maximum coverage, high bond strength, and ultimate peace of mind. CE marked to EN 845‐3.


Offers two unique design features; a flattened ribbed profile and in-line welded cross wires.

  • The unique, flattened, and profiled main structural wires help to improve bond performance compared with traditional smooth wires, allowing for maximum coverage and anchorage in use.
  • The Apollo II’s cross wires, which are sized at 2.75mm diameters, are welded in-line to avoid steel build problems and to create a very robust and durable reinforcement strip.

When combined, these unique design features are responsible for the improved performance of Apollo II. The bond strength is up to 90% stronger than others on the market.


Available in a comprehensive range of widths, materials, and sizes.

  • Available in 5 different main wire diameters – 3.0, 3.5, 4.0, 4.5, and 5.0 mm.
  • Available in 4 product widths to suit UK brick and block sizes.
  • Supplied in 2.7 m long strips with 20 strips per pack.


General information

Finish

Natural

Material

Stainless steel

Length

2700 mm

Width

60 mm

Uniclass

Pr_20_96_71_83 Stainless steel bed joint reinforcementPrimary

CAWS

F30/290 Proprietary special fixings

C41/285 Bed joint reinforcement to masonry

Specification data - Stainless steel bed joint reinforcement

Standard

To BS EN 845-3.

Configuration of bed joint reinforcement

Welded wire ladder.

Dimensions

-

Wire size

5 mm.

Ladder or truss width (overall)

60 mm.

Corrosion protection

To BS EN 845-3, material coating reference R3.

Bond strength

19750 N.

Shear load (maximum)

3500 N.

Guidance for specification option:

Shear load capacity of welds.

Mortar designation

Minimum: General purpose ≥ M4.

Yield strength

600 N/mm².

Guidance for specification option:

Characteristic yield strength of longitudinal and cross wire.

Sustainability data

Contains Red List materials

No

Recyclability

Fully recyclable

Third party certifications

DoP

DoP

Declaration of Performance - Certificate No 037 (EN 845-3)

DoP

DoP

Declaration of Performance - Certificate No 038 (EN 845-3)

DoP

DoP

Declaration of Performance - Certificate No 039 (EN 845-3)

DoP

DoP

Declaration of Performance - Certificate No 040 (EN 845-3)

DoP

DoP

Declaration of Performance - Certificate No 041 (EN 845-3)

Literature

ACS Apollo II Masonry Reinforcement

ACS Apollo II Masonry Reinforcement