NBS Source
I'm a manufacturer

Airlite Highly Insulated Natural Louvred Ventilator

Verified by manufacturer 5 months ago

Colt International Ltd Third party certifications:
  • Certificate of constancy of performance

    Certificate type

High-performance natural louvred ventilator suitable for natural day-to-day climate control as well as smoke control.

Jump to:
+44 (0)23 9245 1111 Website

Application

For inlet and extract ventilation as well as the entry of natural daylight for most kinds of industrial and commercial buildings.

Suitable for either facade or roof applications.

Description

High-performance natural louvred ventilator suitable for natural day-to-day climate control as well as smoke control.


Features and benefits:

  • Energy efficient: designed with the Energy Performance in Buildings Directive in mind, providing exceptionally high insulation and low air leakage.
  • High aerodynamic, thermal and acoustic performance.
  • Exclusive optional movable wind baffle, to overcome side wind effects.
  • Wide range of applications: Classed as a dual-purpose ventilator, can also be installed in the vertical either for low level air inlet or for high level extract.
  • Allows the entry of natural daylight through its polycarbonate blades.
  • Pneumatic or electric controls and a wide range of accessories and finishes.
  • Easy to install.
  • Durable: Manufactured from tough, corrosion resistant aluminium alloy, with stainless steel fixings.
  • Certified performance: Exhaustively tested and certified to EN 12101-2: 2003 in accredited third party test laboratories and is CE marked.
  • Manufactured under strict quality control to ISO 9001.

General information

Finish

Mill

Material

Aluminium

Polycarbonate

Shape

Square

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_70_65_04_56 Natural smoke and heat exhaust ventilatorsPrimary

CAWS

L10/490 Roof ventilators

L10/47 Roof ventilators

Product range

Natural louvred ventilators

Specification data - Natural smoke and heat exhaust ventilators

Standard

To BS EN 12101-2.

Mounting

Roof-mounted, to suit curb.

Wall-mounted, to suit curtain walling

Roof-mounted, to suit glazing

Roof-mounted, to suit sheeting

Reliability classification

Re 1000.

Guidance for specification option:

10 000 cycles.

Snow load classification

Up to 4500 N/m².

Low ambient temperature classification

T (-25).

Wind load classification

Up to 12 500 N/m².

Resistance to heat classification

B300.

Arrangement

Louvred.

Dimensions

-

Length

-

Manufacturer guidance

Insert requirements, 1200–3000 mm in 1 mm increments (throat length).

Width

-

Manufacturer guidance

Insert requirements, 500–2000 mm in 1 mm increments (throat width).

Height

150 mm (when closed).

Controls

24 V d.c.

Pneumatic, double locking.

Pneumatic, failsafe open.

Materials

-

Ventilator

-

Frame

Aluminium.

Louvres

16 mm clear seven-layer multiwall (light transmitting) polycarbonate.

16 mm opaque seven-layer multiwall (light transmitting) polycarbonate.

16 mm grey seven-layer multiwall (non-light transmitting) polycarbonate.

Finish

Mill finish.

Guidance for specification option:

Standard.

Polyester powder coating.

Guidance for specification option:

Insert colour requirement.

Colour

Silver.

Guidance for specification option:

Standard for mill finish.

RAL.

Guidance for specification option:

Insert requirements. Polyester powder coating only.

Integral upstands

-

Material

Double skin insulated aluminium.

Finish

To match ventilator.

Colour

To match ventilator.

Seals

Double seals.

Guidance for specification option:

Double seals on the base and on the louvre are used to reduce air leakage when closed.

Guards

Bird.

Burglar.

Insect.

Security.

Not required.

Accessories

None.

Moveable wind baffle.

Guidance for specification option:

Installed to overcome side wind effects. This closes when the ventilator closes and so is invisible from the outside when the ventilator is closed, thereby enhancing its appearance.

Resistance to fire

E.

Guidance for specification option:

To EN 13501-1.

U-value

Up to 1.02 W/m²K.

Air permeability

Manufacturer's standard.

Guidance for specification option:

Air permeability for a medium size unit of 11.7 m³/h·m² at 50 Pa has been achieved on test.

Sound insulation

Up to 30 dB Rw.

Third party certifications

Certificate of constancy of performance

Certificate of constancy of performance

Certificate of constancy of performance - Airlite