NBS Source
I'm a manufacturer
Compare variants

AirMaster MVHR - Mechanical Ventilation Heat Recovery

Verified by manufacturer 5 months ago

AM 1000

SAV Systems Variant:
Third party certifications:
  • ISO 14025

    Certificate type

Mechanical ventilation with heat recovery for small, medium and large classrooms with a high need for air replacement and a good indoor climate with low CO2 levels at all times.

Jump to:
+44 01483 771 910 Website

Application

Designed for classrooms, but also suitable for ventilation in offices, meeting rooms, and others depending on the model.

Description

Balanced decentralized ventilation systems, suitable for ventilating small, medium and large classrooms depending on the model.


Features and benefits:

  • Ensures good indoor air quality regardless of the external conditions.
  • Draught-free air distribution using the Coanda effect, without ducts or diffuser grilles.
  • Low noise: only 35 dB(A) at 1 m.
  • <30 dB (A) for SEN classrooms.
  • ePM10 50% (M5) minimum filter grade.
  • Demand control links fan speed to room CO₂ levels.
  • 49 dB attenuation of external noise.
  • BB101 and BB93 compliant.
  • Online monitoring on the Internet of Things platform, Airlinq Online.
  • Automatic summer bypass and night-time cooling.
  • No re-circulation of classroom air.
  • Low SFP, high heat recovery.

General information

Color

White

Grey

Finish

Painted

Material

Metal

Shape

Rectangle

Square

Circle

Length

572 mm

705 mm

779 mm

916 mm

687 mm

Show more

Width

1170 mm

1180 mm

1600 mm

1910 mm

800 mm

Show more

Height

261 mm

344 mm

439 mm

474 mm

2323 mm

Show more

Warranty description

Two year

Uniclass

Pr_60_65_03_87 Supply and return air-handling unitsPrimary

CAWS

U90/413 Ventilation fan units

U90/140 Mechanical supply ventilation

Specification data - Supply and return air-handling units

Standard

To EN 1886 and EN 13141-7.

Duty

-

Air volume

-

Supply

ePM₁₀ 50%.

Guidance for specification option:

Standard.

ePM₁ 55%.

Guidance for specification option:

Optional.

ePM₁ 80%.

Guidance for specification option:

Special not stock item.

Extract

ePM₁₀ 50%.

Sound power level

30–35 dB (A).

Environment

Internal.

Casing construction

-

Standard

To BS EN 1886.

Leakage class of casing

L2/A1.

Material

Aluminium.

Finish

Painted.

Method of support

-

Manufacturer guidance

Consult manufacturer and insert requirements or omit.

Components

-

Dampers

-

Purpose

To EN 1751, class 3.

Filters

Extract air filter/ supply air filter.

Heaters

-

Pre-heaters

Not required.

Preheating surface.

Guidance for specification option:

Optional.

Re-heaters

Electric comfort heating surface.

Water comfort heating surface.

Heat recovery

-

Heat recovery equipment

Counterflow heat exchangers.

Attenuators

49 dB attenuation.

Accessories

Not required.

Enthalpy counterflow heat exchanger (polymer membrane).

Guidance for specification option:

Special item (not stock item), consult manufacturer for details.

Combination counterflow heat exchanger (polymer membrane).

Guidance for specification option:

Special item (not stock item), consult manufacturer for details.

Hygrostat (wall-mounted).

Guidance for specification option:

Special item (not stock item), consult manufacturer for details.

Capacitive return for motorized exhaust and supply air dampers.

Electric preheating surface.

Electric comfort heating surface.

Water heating surface.

Condensate pump.

PIR/motion sensor (wall-mounted).

PIR/motion sensor (built-in).

CO2-sensor (wall-mounted).

CO2-sensor (built-in).

TVOC-sensor (built-in).

CO2-/TVOC-sensor (built-in).

Energy meter.

Cooling module, CC (only for horizontal model).

Wall-/ceiling bracket.

Ceiling frame.

Airlinq® Viva control panel.

Airlinq® Orbit control panel.

Airmaster Airlinq® Online.

Airlinq® Online API.

Airlinq® BMS.

LON® module.

Guidance for specification option:

Special item (not stock item), consult manufacturer for details.

KNX® module.

Guidance for specification option:

Special item (not stock item), consult manufacturer for details.

MODBUS® RTU RS485 module.

BACnetTM MS/TP module.

BACnetTM /IP module.

Mini B USB (on front of unit).

Guidance for specification option:

Special item (not stock item), consult manufacturer for details.

Dimensions

2325 x 561 x 1283 mm.

Manufacturer guidance

B x H x D.

Voltage supply

220–240 V/ 50 Hz, ~1N+PE.

Flow rate

1050 m3/h.

Manufacturer guidance

Unit flow rate.

Duct connection

Ø315 mm.

Sustainability data

Country of product manufacture

Denmark

Material

Metal

Manufacturing plant location

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

-

Manufacturer guidance

Information on variant available.

Consult manufacturer for details.

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

ISO 14025

ISO 14025

AirMaster Verified Environmental Product Declaration (EPD)

Literature

AirMaster MVHR - AMX 4

AirMaster MVHR - AMX 4

AirMaster MVHR - AM 50

AirMaster MVHR - AM 50

AirMaster MVHR - AM 150

AirMaster MVHR - AM 150

AirMaster MVHR - AM 300

AirMaster MVHR - AM 300

AirMaster MVHR - AM 500

AirMaster MVHR - AM 500

AirMaster MVHR - AM 800

AirMaster MVHR - AM 800

AirMaster MVHR - AM 900 Displacement

AirMaster MVHR - AM 900 Displacement

AirMaster MVHR - AM 900 Mixing

AirMaster MVHR - AM 900 Mixing

AirMaster MVHR - AM 1000

AirMaster MVHR - AM 1000

AirMaster MVHR - AM 1200 V ⌀400 Roof Cap

AirMaster MVHR - AM 1200 V ⌀400 Roof Cap

AirMaster MVHR - AM 1200 H

AirMaster MVHR - AM 1200 H

AirMaster MVHR - AM 1200 V ⌀350 Roof Cap

AirMaster MVHR - AM 1200 V ⌀350 Roof Cap