Verified by manufacturer 5 months ago
European Technical Approval (ETA)
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
CE and UKCA marked intumescent pipe closer.
For pipe sizes from smallest pipes available to Ø315 mm with a wide range of pipe wall thicknesses.
Astro PFP Pipe Closer are designed to maintain the fire resistance of fire rated walls and floors where these are breached by continuous plastic pipes. Astro PFP Pipe Closer can be used in gypsum, masonry and concrete walls and with concrete floors. Each pipe closer consists of a Red/Silver coated circular steel shell that splits in two to fit around the service penetrations by means of a simple 'slide-lock' system.
The steel shell contains a graphite based reactive material which reacts when exposed to heat closing the openings left by the softening plastic pipe in fire.When testing pipes, one can choose not to cap (or close) the pipe, or cap the pipe inside the furnace, or outside the furnace, or on both sides. The configuration chosen depends on the intended application of the pipe and/or the installation environment.
The code defining if a pipe is capped is stated after the fire classification. For instance EI 60 C/U which means the pipe was capped inside the furnace, and uncapped outside the furnace. The test configuration defines the approvals possible.
Features and benefits:
Color | Red Silver |
Finish | Gloss |
Material | Steel Graphite |
Shape | Circle |
Length | 32 mm 40 mm 55 mm 63 mm 75 mm Manufacturer guidanceDiameter |
Height | 50 mm 60 mm 75 mm Manufacturer guidanceDepth |
Uniclass | |
CAWS | J41/480 Pipe collars J40/370 Preformed collars for pipes, ducts, cables, etc. P12/370 Pipe collar P12/43 Pipe collar |
Third-party certification | UKCA: 0843-UKTA-23/0026, 0843-CPR-1318. |
Sizes | AFPFPPC32 Astro PFP Pipe Closer: 32 mm (Depth 50 mm).AFPFPPC40 Astro PFP Pipe Closer: 40 mm (Depth 50 mm).AFPFPPC55 Astro PFP Pipe Closer: 55 mm (Depth 50 mm).AFPFPPC63 Astro PFP Pipe Closer: 63 mm (Depth 50 mm).AFPFPPC75 Astro PFP Pipe Closer: 75 mm (Depth 50 mm).AFPFPPC82 Astro PFP Pipe Closer: 82 mm (Depth 50 mm).AFPFPPC90 Astro PFP Pipe Closer: 90 mm (Depth 50 mm).AFPFPPC110 Astro PFP Pipe Closer: 110 mm (Depth 50 mm).AFPFPPC125 Astro PFP Pipe Closer: 125 mm (Depth 60 mm).AFPFPPC140 Astro PFP Pipe Closer: 140 mm (Depth 60 mm).AFPFPPC160 Astro PFP Pipe Closer: 160 mm (Depth 60 mm).AFPFPPC200 Astro PFP Pipe Closer: 200 mm (Depth 60 mm).AFPFPPC250 Astro PFP Pipe Closer: 250 mm (Depth 75 mm).AFPFPPC315 Astro PFP Pipe Closer: 315 mm (Depth 75 mm). |
Fire performance | Fire classifications up to 240 minutes for both integrity |
Expansion | Expansion ratio 17:1, Expansion pressure 65.4 N. Normal expansion time Less than 2 minutes. Minimum expansion |
Durability | Z2 intended for use in internal conditions with humidity classes other than Z1, excluding temperatures below 0°C. |