Verified by manufacturer 3 months ago
BASWA Cool Base – 30 mm
Active thermal-acoustic lining for high performance sound absorption, with integrated radiant heating and cooling and a seamless finish.
Thermal-acoustic lining system which reduces the reverberation time in ceilings and wall surfaces and controls the temperature of a room. It uses an embedded capillary pipe system to provide efficient radiant heating and cooling.
Features and benefits:
Components:
Color | White Guidance for specification option: Standard, NCS 0500-N. Other Guidance for specification option: Surface coatings may be colour matched to any colour code or physical sample. |
Finish | Smooth |
Material | Glass Fibre Guidance for specification option: Glass fibre acoustic panel with polypropylene thermal components and marble surface coating. |
Shape | Rectangle |
Length | 600 mm |
Width | 800 mm |
Height | 21 mm 31 mm 41 mm 61 mm |
Warranty description | Five year |
Uniclass | |
CAWS | K13/170 Acoustic panel lining K13/170 Acoustic panel lining |
Product range |
System performance | Combined acoustic, active heating and cooling performance, up to αw = 0.65, NRC = 0.85, Class C. |
Acoustic insulation | Glass wool insulation. |
Panelling | |
Type | BASWA Phon thermal-acoustic panel using embedded capillary pipe system. |
Surface material | BASWA Classic Base coating, glass fibre board (pressure and tension-resistant), 6 mm open pore pre-coating, recycled glass granulate (Poraver), organically combined. |
Surface finish | Smooth, seamless to Q2 standard (Q3 maximum), resistant surface.Guidance for specification option:
|
Fasteners | Adhered, BASWA Fix C.Guidance for specification option:
Adhered, BASWA Fix K.Guidance for specification option:
|
Samples required | Not required.Required.Guidance for specification option: QM/ QC check and colour matching process. |
System accessories | Not required.Access hatches.Guidance for specification option: The BASWA inspection opening flaps are individually height-adjustable and already RAL9010 PUR-coated. Stop beads.Trims.BASWA fastening rod.Guidance for specification option: Additional mechanical fastening of bonded acoustic panels with BASWA fastening rod for supporting effect, to prevent third-party damage. BASWA Protect.Guidance for specification option: A specially developed premium impregnation system to achieve deep water repellency, with optimum protection for BASWA acoustic surfaces. BASWA Blonde.Guidance for specification option: Bleaching agent for removal of partial organic soiling, such as drink stinks, grease and nicotine. BASWA Clean.Guidance for specification option: Special enzyme cleaner for removal of partial organic soiling, such as drink stinks, grease and nicotine. BASWA Fresh.Guidance for specification option: Mineral dispersion technology, used to renovate age and use-related discolourations of BASWA surfaces. BASWA Casual.Guidance for specification option: Acoustic spray plaster, which is used for the renovation of existing BASWA acoustic surfaces. BASWA IP.Guidance for specification option:
BASWA Fill.BASWA L-angle profiles.Guidance for specification option: PVC or powder-coated aluminium can be used to build edges, offering protection against mechanical damage. BASWA PVC edge protection profiles.Manufacturer guidanceConsult manufacturer. |
Execution | Certified BASWA installer. |
Thickness | 30 mm. |
Colour/ Texture | NCS S 0500-N. Guidance for specification option: Standard. Manufacturer guidanceConsult manufacturer and insert requirements. |
Noise reduction coefficient (NRC) | 0.60/ 0.60. Manufacturer guidanceTo ASTM E 1264: Solid ceilings (on concrete)/ Suspension 200 mm. |
Sound absorption | αw = 0.65 (SAA = 0.59), Class C/ αw = 0.60 (SAA = 0.59), Class C. Manufacturer guidanceTo ISO 11654: Solid ceilings (on concrete)/ Suspension 200 mm. |
Thermal resistance (R-value) | 0.68 m²·K/W. |
Thermal transmittance (U-Value) | 1.47 W/m²·K. |
ThermalConductivity | λ = 0.044 W/m·K. |
Weight | 24 kg/m² (approximate). |
Adhesive bond | 30 kg/m² (tensile). Guidance for specification option: Minimum substrate adhesive tensile strength. |
TemperatureRange | Application: 15–30°C, Building use: 17.5–27.5°C (recommended). Guidance for specification option:
|
RelativeHumidity | At 25°C: 70% RH (maximum), 80% RH (absolute maximum after consultation). Guidance for specification option:
|
Colour (Light reflectance value (LRV) | 0.75. Guidance for specification option: Degree of whiteness (CIE-Y-Value): 89.61, L-value up to 90%. Manufacturer guidanceValues refer to measurements carried out according to DIN EN ISO 11664-4, according to CIELAB system. |
Grain size | 0.7 mm. Guidance for specification option: Roughest surface structure. Manufacturer guidanceFinal layer. |
Reaction to fire (to BS EN 13501-1) | B–s1, d0. |
VOC emissions | Indoor Air Comfort GOLD®. |
Control options | Flow temperature control constant with fixed defined setpoint. Flow temperature control variable according to enthalpy or fixed temperature curve. |
Basecoat | BASWA Base, 0.7 mm. BASWA Base Cool, 0.7 mm. |
NominalCoolingCapacity | At Δ15 K: 117.7 W/m². Guidance for specification option:
|
NominalHeatingCapacity | At Δ8 k: 79.1 W/m². Guidance for specification option:
|
Contains Red List materials | No |
Country of material origin | Switzerland |
Country of product manufacture | Switzerland |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceSee BASWA EPD document. |
Recyclability | Manufacturer guidanceSee BASWA EPD document. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 94 % Manufacturer guidanceSee BASWA EPD document. |