NBS Source
I'm a manufacturer

Bauder Thermoplan FPO Warm Roof System - Mechanically Fixed

Verified by manufacturer 1 year ago

Bauder Ltd Third party certifications:
  • EPD

    EPD

    Certificate type

  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • CCPI System

    CCPI System

    Certificate type

Mechanically fixed, warm roof, single ply waterproofing system suitable for new build, refurbishment and extensive green roof applications. A range of membrane colours and thicknesses are available.

Jump to:
BOS
+44 (0)1473 257671 Website

Application

Suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios. Can also be used for extensive green roof situations.

Description

Single ply Thermoplan T flexible polyolefin warm roof system, incorporating Thermoplan single ply membrane, insulation and air and vapour control layer (AVCL) for adhesive bonding or mechanical fixing.

Bauder Single Ply Thermoplan T Flexible Polyolefin Warm Roof system is suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios. Can also be used for extensive green roof situations. The system can be mechanically fixed or adhesive bonded.

 

Characteristics of the system

  • Membrane thicknesses available 1.5, 1.8 and 2.0mm.
  • Thermoplan membrane has a pre-coated cross weave polyester reinforcement.
  • Acoustic rain noise solution with thirty party testing laboratory SRL is available from Bauder Technical Department.
  • Comprehensive range of guarantee packages to fulfil cover requirements for the project (dependant on system/product selection). For more information contact our technical dept for a sample guarantee outlining cover level, terms and conditions.


Verified properties

  • CCPI Verification 0007700025/1025​: This systems CCPI mark provides accuracy of data delivering assurance to specifiers. 
  • BBA Certificate 04/4120:
  • Fire classification BROOF(t4) to BS EN 13501-5 tested to TS 1187 test 4 for external fire exposure on defined permutations of product build up.
  • Fire properties – membranes deemed “unrestricted” in certain circumstances as categorised in BBA certificate.
  • Service life > 30 years.
  • EPD Certification: Membranes, Insulations.
  • FM Approval: Defined assemblies are approved for mechanically fastened and ballasted installations.

General information

Finish

Smooth

Material

Polyolefin

Guidance for specification option:

Flexible polyolefin (FPO) membrane.

Shape

Square

Rectangle

Height

1.5 mm

2 mm

3.5 mm

Guidance for specification option:

Total thickness for BauderTHERMOPLAN T 15 V FR fleece-backed reinforced FPO membrane. 3.5 mm with 2mm fleece.

Manufacturer guidance

BauderTHERMOPLAN membrane comes in 3 unfleecebacked thicknesses and 1 fleecebacked option

Warranty description

-

Manufacturer guidance

Guarantee options could include ‘Product’, ‘Product and Workmanship’ and ‘Product, Workmanship and Design’ Guarantees. All guarantees available for this system are subject to the works being carried out in accordance with the Bauder specification and being installed by a Bauder Approved installer. For full details and further information regarding guarantees and alternative systems please contact a local Bauder Representative or technical@bauder.co.uk.

Uniclass

Ss_30_40_30_80 Single layer sheet warm roof covering systemsPrimary

CAWS

J42/10 Warm deck roof covering

J42/110 Warm deck roof covering

Product range

Single Ply Systems

Specification data - Single layer sheet warm roof covering systems

Preparation

-

Horizontal work

Activator-Primer (Canister) APR01 – Black.

Guidance for specification option:

Synthetic rubber resin-based primer, developed to provide the necessary preparation of substrates prior to the installation of self-adhesive and torch-applied membranes. The spray application offers improved film thickness, speed of application (by up to 50% over roller applied products) and quick drying in a matter of minutes.

  • Coverage: Approximately 96 g/m² (300 mm wide spray one coat, 192 g/m² two coats). Two coats may be required for very porous substrates.
  • Application temperature: +5 to +30°C.
  • Drying time (at 10°C): 5–10 minutes.
  • Colour: Black.
  • Recoat time if left exposed: Four hours.
  • Suitable substrates: Oriented strand board (OSB); plywood; timber; lightweight concrete or cementitious materials; metal; Bauder self-adhesive underlayers; existing asphalt and bitumen membranes; polyisocyanurate (PIR) insulation.
  • Non-suitable substrates: Concrete decks (new and refurbished); mica finished surfaces (e.g. BauderTEC KSD FBS); laminated paper-foil faced insulation; expanded polystyrene (EPS) or extruded polystyrene (XPS) insulations; BauderROCK or mineral wool insulation; BauderGLAS or cellular glass insulation; copper; thermoplastic waterproofing membranes.

Manufacturer guidance

Contact manufacturer to confirm substrate suitability if required.

Skirtings and vertical work

Bauder Membrane Adhesive (Adhered to substrate).

Thermoplan T membrane (Mechanically fastened).

Manufacturer guidance

The waterproofing should be turned up by at least 150 mm around features such as rooflights, parapets and service pipes passing through the roof. Detail work to upstands, edge details, flashings, etc. should be carried out using Thermoplan unreinforced TL membrane adhered directly to the substrate using suitable Bauder Membrane Adhesive or mechanically fixed using Thermoplan T membrane. Detailing should be carried out with a separate flashing. Consult manufacturer for further information on detailing.

Air and vapour control layer

-

Type

TEC DBR 06.

Guidance for specification option:

Self-adhesive elastomeric bitumen air and vapour control layer (AVCL), with an aluminium foil facing for vapour impermeability. The bottom is a peel off release film, covering self-adhesive bitumen. The product is thinner than other air and vapour control layers and is therefore lightweight.

For mechanically fixed insulation only; not suitable for use on concrete decks.

  • Width: 1.25 m.
  • Length: 32 m.
  • Thickness: 0.6 mm.
  • Weight: 0.6 kg/m².
  • Reinforcement: Aluminium foil and 50 g/m² polyester.
  • Tensile strength: Length ≥ 950 N/50mm and Diagonal ≥ 750 N/50mm.
  • Cold bending test: -40°C.
  • Elongation at break: Length and Diagonal ≥ 4%.

TEC KSD Foil.

Guidance for specification option:

Self-adhesive elastomeric bitumen air and vapour control layer (AVCL), with an aluminium foil facing for vapour impermeability. The bottom is a peel off release film, covering self-adhesive bitumen.

Note: Not suitable for use on concrete decks.

  • Width: 1 m.
  • Length: 15 m.
  • Thickness: 1.5 mm.
  • Weight: 1.8 kg/m².
  • Reinforcement: 60 g/m² glass fleece.
  • Tensile strength: Length and Diagonal ≥ 400 N/50mm.
  • Cold bending test: -30°C.
  • Elongation at break: Length and Diagonal ≥ 2%.

BauderTEC KSD FBS.

Guidance for specification option:

Robust, self-adhesive elastomeric bitumen air and vapour control layer (AVCL), with a mica finished upper surface to allow easy bonding of insulation using appropriate Bauder Insulation Adhesive. One side lap features an 80 mm wide glass fleece along the underside, and a 100 mm strip of aluminium foil above. The other side lap has a thermofusible film on the top surface. This arrangement ensures that laps are heat sealed using hot air or gas torch as appropriate to extrude a bitumen bead, thus ensuring waterproofing integrity.

  • Width: 1.08 m.
  • Length: 10 m.
  • Thickness: 2.5 mm.
  • Weight: 2.5 kg/m².
  • Reinforcement: Polyester coated aluminium foil and 200 g/m² glass fleece.
  • Tensile strength: Length and Diagonal ≥ 1000 N/50mm.
  • Cold bending test: -25°C.
  • Elongation at break: Length and Diagonal ≥ 2%.

Insulation

-

Type

BauderGLAS Flatboard.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Twin cartridge or mechanically fixed.

Cellular glass insulation suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass flatboard insulation board.
  • Facing: Glass tissue or none faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Board thickness (Flatboard): 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm (also available in tapered).
  • Thermal conductivity: 0.036 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².

BauderGLAS Tapered.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Twin cartridge or mechanically fixed.

Cellular glass insulation suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass tapered insulation board.
  • Facing: Glass tissue or none faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Board thickness (Flatboard): 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm (also available in tapered).
  • Thermal conductivity: 0.036 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².

BauderROCK Flatboard.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Twin cartridge or mechanically fixed.

Mineral fibre insulation suitable for projects that require a high level of sound reduction. Non-combustible and has a zero GWP and ODP rating.

  • Type: Dual density mineral wool flatboard insulation board.
  • Facing: Top: 300 g/m² glass fibre fleece; Bottom: Unfaced.
  • Density: 160 kg/m².
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 170 mm, 185 mm (also available in tapered).
  • Thermal conductivity: 0.039 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).

BauderROCK Tapered.

Guidance for specification option:

Insert required thickness.


Can only be used with PU Insulation Adhesive – Twin cartridge or mechanically fixed.

Mineral fibre insulation suitable for projects that require a high level of sound reduction. Non-combustible and has a zero GWP and ODP rating.

  • Type: Dual density mineral wool tapered insulation board.
  • Facing: Top: 300 g/m² glass fibre fleece; Bottom: Unfaced.
  • Density: 160 kg/m².
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 170 mm, 185 mm.
  • Thermal conductivity: 0.039 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).

PIR FA Flatboard.

Guidance for specification option:

Insert required thickness.


  • Type: Rigid closed-cell polyisocyanurate (PIR) roofboard: To BS EN 13165.
  • Facing: Black aluminium foil to both faces.
  • Density: >30 kg/m³.
  • Standard board size: 1200 x 2400 mm.
  • Thickness: 30 mm, 40 mm, 50 mm, 60 mm, 80 mm, 100 mm, 120 mm, 140 mm, 160 mm.
  • Thermal conductivity: 0.022 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm².
  • PIR index: >250 (extremely high dimensional stability).

PIR FA Tapered board 1:60.

Guidance for specification option:

Insert required thickness.


  • Type: Rigid closed-cell polyisocyanurate (PIR) roofboard: To BS EN 13165.
  • Facing: Black Aluminium Foil to both faces.
  • Density: >30 kg/m³.
  • Standard board size: 1200 x 1200 mm.
  • Board thickness: Contact manufacturer for options.
  • Thermal conductivity: 0.022 W/m·K.
  • Compressive strength: >0.12 N/mm².
  • PIR index: >250 (extremely high dimensional stability).

PIR FA-TE Flatboard.

Guidance for specification option:

Insert required thickness.


  • Type: Rigid closed-cell polyisocyanurate (PIR) roofboard: To BS EN 13165.
  • Facing: Aluminium foil to both faces.
  • Density: >30 kg/m³.
  • Standard board size: 1200 x 600 mm.
  • Thickness: 30 mm, 40 mm, 50 mm, 60 mm, 80 mm, 100 mm, 120 mm, 140 mm, 160 mm.
  • Thermal conductivity: 0.022 W/m·K (may vary dependent on thickness specified).
  • Compressive strength: >0.12 N/mm².
  • PIR index: >250 (extremely high dimensional stability).

Attachment

PU Insulation Adhesive – Tin.

Guidance for specification option:

Not for foil to foil applications (e.g. FA on KSD Foil).

PU Insulation Adhesive – Twin cartridge.

Waterproof covering

-

Type

Thermoplan T 15 V.

Guidance for specification option:

Bauder Thermoplan T SV 15 Fleece-Backed Membrane is a polyester reinforced flexible polyolefin membrane (FPO), an alloy of thermoplastic and rubber. A polyester fleece is laminated to the underside of the membrane in factory conditions. This combination gives high tensile strength, good thermal stability and flexibility.

  • Width: 1.5 m.
  • Length: 20 m.
  • Thickness: 2.5 mm (includes 1 mm fleece).
  • Weight: 2.1 kg/m².
  • Surface: Silver Grey (RAL 7001), Pearl White (RAL 1013).
  • Bottom: Polyester fleece.
  • Reinforcement: Pre-coated cross-weave polyester.
  • Tensile strength: ≥ 1200 N/50mm.
  • Cold bending test: ≥ -30°C.
  • Elongation at break: 19%.

Thermoplan T 12.

Guidance for specification option:

Bauder Thermoplan T SV 12 is a 1.2 mm gauge polyester reinforced flexible polyolefin membrane (FPO), an alloy of thermoplastic and rubber. This combination gives high tensile strength, good thermal stability and flexibility.

  • Width: 1.5 m.
  • Length: 20 m.
  • Thickness: 1.2 mm.
  • Weight: 1.50 kg/m².
  • Surface: Silver Grey (RAL 7001), Pearl White (RAL 1013) – (T SV 12 – 1.2 mm and T SV 20 – 2 mm available in Pearl White Only).
  • Bottom: Black.
  • Reinforcement: Pre-coated cross-weave polyester.
  • Tensile strength: ≥ 1200 N/50mm.
  • Cold bending test: ≥ -30°C.
  • Elongation at break: 19% (U20 – 20%).

Thermoplan T 15.

Guidance for specification option:

Bauder Thermoplan T SV 15 is a 1.5 mm gauge polyester reinforced flexible polyolefin membrane (FPO), an alloy of thermoplastic and rubber. This combination gives high tensile strength, good thermal stability and flexibility.

  • Width: 1.5 m.
  • Length: 20 m.
  • Thickness: 1.5 mm.
  • Weight: 1.80 kg/m².
  • Surface: Silver Grey (RAL 7001), Pearl White (RAL 1013) – (T SV 12 – 1.2 mm and T SV 20 – 2 mm available in Pearl White Only).
  • Bottom: Black.
  • Reinforcement: Pre-coated cross-weave polyester.
  • Tensile strength: ≥ 1200 N/50mm.
  • Cold bending test: ≥ -30°C.
  • Elongation at break: 19% (U20 – 20%).

Thermoplan T 20.

Guidance for specification option:

Bauder Thermoplan T SV 20 is a 2 mm gauge polyester reinforced flexible polyolefin membrane (FPO), an alloy of thermoplastic and rubber. This combination gives high tensile strength, good thermal stability and flexibility.

  • Width: 1.5 m.
  • Length: 20 m.
  • Thickness: 2 mm.
  • Weight: 2.40 kg/m².
  • Surface: Silver Grey (RAL 7001), Pearl White (RAL 1013) – (T SV 12 – 1.2 mm and T SV 20 – 2 mm available in Pearl White Only).
  • Bottom: Black.
  • Reinforcement: Pre-coated cross-weave polyester.
  • Tensile strength: ≥ 1200 N/50mm.
  • Cold bending test: ≥ -30°C.
  • Elongation at break: 19% (U20 – 20%).

Manufacturer guidance

To be fully specified separately.

Attachment

Membrane and insulation fasteners.

Guidance for specification option:

Bauder only approves the use of fasteners from manufacturer/ supplier companies with associate membership to SPRA. Fasteners are included within the Bauder guarantee when supplied from SFS Group Fastening Technology Ltd when the project is covered by a Bauder Ltd Product and Workmanship guarantee.

PU Fleece Backed Membrane Adhesive – Canister.

Guidance for specification option:

For adhering T SV 15 FB to all insulation and deck types.

System accessories

Not required.

Bauder Thermoplan TL FPO Detailing Membrane.

Guidance for specification option:

  • This unreinforced detailing membrane is manufactured from flexible polyolefin membrane (FPO), an alloy of thermoplastic and rubber. This combination provides high elongation, good thermal stability and flexibility. Complex three-dimensional detailing to curves, pipes or awkward shapes to be formed using Thermoplan un-reinforced TL membrane. Otherwise Thermoplan pre-formed corners must be used at intersections and returns.
  • Available in both membrane colours: Silver Grey (RAL 7001), Pearl White (RAL 1013).
  • Membrane to be either fully bonded using the appropriate Bauder contact adhesive or mechanically fixed according to the construction – refer to the Bauder Single Ply Installation Manual for further guidance.

Bauder Thermoplan Pre-formed Corners.

Guidance for specification option:

  • Pre-formed FPO internal and external corners for use with Thermoplan membrane.
  • These products are designed to dress into 90° corners, they can be warmed and manipulated to fit corners over and under 90°. If this is not possible a gusset must be dressed to an internal corner and a piece of TL unreinforced detailing membrane can be used to an external corner with a ‘thumb print’.
  • Internal (90 x 90 mm) and External (150 x 170 mm) pre-formed corners can be reversed to allow them to be used at other junction points to ensure a watertight seal is easy to achieve.
  • Pre-formed corners must be fully heat welded from the centre outwards working around each side until the entire patch is welded.
  • Available in both membrane colours: Silver Grey (RAL 7001), Pearl White (RAL 1013).
  • For information contact Bauder Technical Department.

BauderFPO VBL 14 Laminated Metal.

Guidance for specification option:

  • 1.4 mm thick. A 0.6 mm thick, hot dip galvanized steel plate, laminated on one side with 0.8 mm thick layer of Thermplan FPO, for use in creating flashings and detailing.
  • Available in both membrane colours: Silver Grey (RAL 7001), Pearl White (RAL 1013).
  • Bauder Thermoplan Coated Metal (1 x 2 m) is supplied in pallet quantities in flat sheet form.
  • Full fixing and installation information can be found in the Single Ply Technical installation Guide.

Bauder single ply lightning conductor clips.

Guidance for specification option:

  • A specialist lightning conductor clip riveted to a Bauder membrane base. These clips are available to suit coated 25 x 3 mm conductor tape. The membrane base is Thermoplan FPO. The base allows the product to be fully bonded to the waterproofing, whilst the clip allows movement of the tape caused by expansion/ contraction.
  • Available in both membrane colours: Silver grey (RAL 7001), Pearl White (RAL 1013).

Bauder Thermoplan Rigid FPO rainwater outlets.

Guidance for specification option:

  • A rigid FPO rainwater outlet enabling Thermoplan membrane to be welded to the flange plate. UV stable throughout. The unbacked Thermoplan membrane should be heat welded up to the aperture to ensure colour consistency on the roof.
  • Rigid FPO base plate in beige: 300 mm (70 DN), 385 mm (100 DN and 150 DN).
  • Rigid FPO spigot length: 300 mm.

Bauder outlets are sized to indicate the actual internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department.

  • Thermoplan Rigid FPO Rainwater Outlet DN 70: Flow rate 4.6 L/s (including leaf guard).
  • Thermoplan Rigid FPO Rainwater Outlet DN 100: Flow rate 5.5 L/s (including leaf guard).
  • Thermoplan Rigid FPO Rainwater Outlet DN 150: Flow rate 6.6 L/s (including leaf guard).

Bauder Locking Leaf Guard – Long Leg for Rigid FPO Vertical Outlets.

Guidance for specification option:

  • A universal leaf guard compatible with Thermoplan Rigid FPO rainwater outlets for preventing debris blocking the outlet.
  • For outlet spigot dimensions ranging from 60–220 mm. Grip Range Depth: 80–105 mm. This product is UV stable.
  • Material: Polyamide.
  • Colour: Black.

This Bauder Leaf Guard is designed to fit into Bauder Rigid FPO rainwater outlets. For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department.

Bauder Thermoplan Stainless Steel rainwater outlets.

Guidance for specification option:

A high performance stainless steel outlet with factory installed Thermoplan membrane flange. Supplied with an O-ring and a wire ball leaf grill.

  • Stainless steel base plate: 250 x 250 mm.
  • Thermoplan membrane flange: 350 x 350 mm (Pearl White).
  • Stainless steel spigot length: 400 mm.

Bauder outlets are sized to indicate the actual internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department.

  • Thermoplan Stainless steel Rainwater Outlet DN 70: Flow rate 2.98 L/s (including leaf guard).
  • Thermoplan Stainless steel Rainwater Outlet DN 100: Flow rate 3.94 L/s (including leaf guard).
  • Thermoplan Stainless steel Rainwater Outlet DN 150: Flow rate 6.76 L/s (including leaf guard).

Bauder Thermoplan Rigid FPO Parapet Outlet.

Guidance for specification option:

A rigid FPO parapet rainwater outlet enabling Thermoplan membrane to be welded to the flange plate. UV stable throughout. The unbacked Thermoplan membrane should be heat welded up to the aperture to ensure colour consistency on the roof.

  • Rigid PVC base plate in beige: 280 x 180 x 110 mm (W x H x D).
  • Rigid PVC spigot length: 480 mm.
  • Thermoplan Rigid FPO Rainwater Outlet: Flow rate 0.75 L/s.

Bauder outlets are sized to show the internal diameter of the spigot. For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department.

Bauder Thermoplan Emergency Overflow Outlet.

Guidance for specification option:

  • An extruded FPO emergency overflow outlet compatible with Thermoplan membrane.
  • 50 mm diameter through wall overflow outlet manufactured pearl white (RAL 1013) colour.
  • Flange dimeter: 300 mm.
  • Spigot length: 480 mm.
  • For information on non-standard sizes and refurbishment applications, contact Bauder Technical Department.

BauderFPO WWB embossed walkway membrane.

Guidance for specification option:

Bauder Thermoplan Embossed Walkway Membrane is a 2 mm thick reinforced membrane made from TPO-PP, bitumen compatible with embossed surface.

The walkway membrane should be heat welded around its full perimeter to the surface of the finished waterproofing.

BauderSOLAR Photovoltaic Mounting System.

Guidance for specification option:

Bauder Flat roof PV mounting solution for framed solar modules. The mounting units are secured to the roof using a membrane-to-membrane welding technique. This installation method means that the roof is not compromised by penetrations for fixings nor is it ballasted, which would add additional weight loading to the roof. Specifically designed to be installed on Bauder bituminous or single ply waterproofing systems and provide a lightweight, low risk and quick to install mounting solution for framed solar modules.

Bauder LiquiFIBRE Detailing Kit.

Guidance for specification option:

Fast curing waterproofing resin containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent, isocyanate and halogen free.

Bauder LiquiDETAIL.

Guidance for specification option:

Cold liquid applied fast curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing and is solvent, isocyanate and halogen free.

Bauder rooflights/ glazing/ ventilation.

Guidance for specification option:

All these glazing products are fully compatible with the roof waterproofing systems. Consult manufacturer for details and insert requirements.

  • BauderDOME Rooflight.
  • Bauder Euroglaze Rooflight.
  • Bauder Special Modular Rooflight.
  • Bauder Continuous Rooflight.
  • Bauder Walk-on Rooflight.
  • Bauder Direct Glazing.
  • Bauder AOV.
  • Bauder Modular Link Glazing.
  • Bauder Structural Rooflight.
  • Bauder Fire Rated Rooflight.

Sustainability data

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

3

IFC
-

1

Third party certifications

EPD

EPD

Environmental Product Declaration - Bauder Thermoplan

BBA Agrément Certificate

BBA Agrément Certificate

Certification: Thermoplan Membranes 04/4120

CCPI System

CCPI System

Bauder Thermoplan CCPI

Similar products from Bauder Ltd

Bauder Single Ply Thermofol Warm Roof Membrane System Mechanically Fixed Insulation & Adhered Membrane

Bauder Single Ply Thermofol Warm Roof Membrane System Mechanically Fixed Insulation & Adhered Membrane

Bauder Thermofol PVC Warm Roof System - Adhered

Bauder Thermofol PVC Warm Roof System - Adhered

Bauder Thermofol PVC Warm Roof System - Mechanically Fixed

Bauder Thermofol PVC Warm Roof System - Mechanically Fixed

Bauder Thermoplan FPO Warm Roof System - Adhered