NBS Source
I'm a manufacturer

Bauder Total Green Roof System Reinforced Bitumen Membrane Warm Roof Covering System - Torch Applied.

Verified by manufacturer 7 months ago

Bauder Ltd Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • CCPI System

    CCPI System

    Certificate type

  • EPD

    EPD

    Certificate type

Two-layer, torch-applied, warm roof bitumen membrane waterproofing system suitable for new build and refurbishment applications, incorporating torch-on bitumen root resistant capping sheet.

Jump to:
BOS
+44 (0)1473 257671 Website

Application

Suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios.

Description

Two-layer, torch-applied, warm roof bitumen membrane waterproofing system, suitable for both new build and refurbishment applications on non-combustible substrates (i.e. concrete).

 

Total green warm roof system, two-layer, torch-applied, warm roof, bitumen membrane waterproofing system, insulation and torch-applied bitumen air and vapour control layer (AVCL).


Total Green Roof System is suitable for a variety of applications on both new build and refurbishment projects and can be used in warm, cold and inverted roof scenarios.

 

Plus points:

  • 5.2 mm styrene-butadiene-styrene (SBS) modified elastomeric bitumen cap sheet with polyester fleece reinforcement.
  • Range of guarantee packages to fulfil cover requirements for project (dependent of system/ product selection). For more information contact Bauder's technical department for a sample guarantee outlining cover level, terms and conditions.
  • Standards: BS EN 13707 Reinforced Bitumen Membrane Sheets for Roof Waterproofing.


Verified properties:

  • CCPI Verification 0007700016/1025: This systems CCPI mark provides accuracy of data, delivering assurance to specifiers.
  • BBA Certificate 10/4744.
  • Fire properties - membranes deemed "unrestricted" in certain circumstances as categorized in BBA Certificate.
  • Service life > 30 years as stated in BBA certificate.
  • EPD Certification on system components: Bitumen membranes, BauderROCK insulation, BauderGLAS Insulation.

General information

Color

Green

Guidance for specification option:

Mineral finish is green.

Finish

Mineral

Material

Bitumen

Guidance for specification option:

Elastomer modified bitumen membrane.

Shape

Square

Rectangle

Warranty description

-

Manufacturer guidance

Guarantee options could include ‘Product’, ‘Product and Workmanship’ and ‘Product, Workmanship and Design’ Guarantees. All guarantees available for this system are subject to the works being carried out in accordance with the Bauder specification and being installed by a Bauder Approved installer. For full details and further information regarding guarantees and alternative systems please contact the local Bauder Representative or technical@bauder.co.uk.

Uniclass

Ss_30_40_30_72 Reinforced bitumen membrane warm roof covering systemsPrimary

CAWS

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

J41/10 Reinforced bitumen membrane warm deck roof covering

Specification data - Reinforced bitumen membrane warm roof covering systems

Preparation

-

Horizontal work

Bauder Quick Dry Bitumen Primer.

Guidance for specification option:

A bitumen-based primer applied by a roller or brush. ‘Quick Dry’ is in comparison to standard bitumen primers. Specially formulated to increase the bond strength of Bauder torch-on bitumen membranes and Bauder Hot Melt waterproofing.

  • Coverage: 4-8 L/m2 (depending on substrate porosity).
  • Application temperature: +5 to +25°C. (Where the temperature falls outside of this, please refer to Summer & Winter Advice documents from Bauder).
  • Drying time: 3-6 hours depending on porosity and weather conditions.
  • Colour: Black.
  • Recoat time: 4 hours (if left exposed).
  • Suitable substrates: concrete; lightweight concrete or cementitious materials; metal; brick.

Manufacturer guidance

Contact manufacturer to confirm substrate suitability if required.

Skirtings and vertical work

As 'Horizontal work'.

Air and vapour control layer

-

Type

Bauder Super AL-E.

Guidance for specification option:

A robust, torch-applied, styrene-butadiene-styrene (SBS) elastomeric bitumen air and vapour control layer, featuring a tear-resistant aluminium foil lining for vapour impermeability. Once installed, the product provides a temporary waterproofing layer, allowing internal works to be carried out immediately.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 3.5 mm.
  • Surface finish: top: mica; bottom: thermofusible polyethylene.
  • Weight: 4.5 kg/m².
  • Reinforcement: polyester-coated aluminium foil and 60 g/m² glass fleece.
  • Tensile strength: ≥400 N/50mm (length and diagonal).
  • Heat stability: +70°C.
  • Cold bending test: -20°C.
  • Elongation at break: ≥2% (length and diagonal).

Attachment

Torch applied.

Insulation

-

Type

BauderGLAS Flatboard.

Guidance for specification option:

Insert required thickness.

 

Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – twin cartridge.


Suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass flatboard insulation board.
  • Facing: Glass tissue or none-faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Thickness: 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm.
  • Thermal conductivity: 0.036 W/m·K (may vary, dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².


BauderGLAS Tapered.

Guidance for specification option:

Insert required thickness.

 

Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – twin cartridge.


Suitable for projects that require a high level of compressive strength and/ or to be non-combustible.

  • Type: Cellular glass tapered insulation board.
  • Facing: Glass tissue or none-faced (depending upon system).
  • Density: 100 kg/m³.
  • Board size: Contact manufacturer for options.
  • Thickness (maximum): 50 mm, 60 mm, 70 mm, 80 mm, 90 mm, 100 mm, 110 mm, 120 mm, 130 mm, 140 mm, 150 mm, 170 mm, 180 mm.
  • Thermal conductivity: 0.036 W/m·K (may vary, dependent on thickness specified).
  • Compressive strength: 0.5 N/mm².


BauderROCK Flatboard.

Guidance for specification option:

Insert required thickness.

 

Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – twin cartridge or mechanically fixed.


Mineral fibre insulation, suitable for projects that require a high level of sound reduction and/ or to be non-combustible; it has a zero GWP and ODP rating.

  • Type: Dual density mineral wool flatboard.
  • Facing: Top: 300 g/m² glass fibre fleece; bottom: unfaced.
  • Density: 160 kg/m³.
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 185 mm (also available in tapered).
  • Thermal conductivity: 0.039 W/m·K (may vary, dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).


BauderROCK Tapered.

Guidance for specification option:

Insert required thickness.

 

Can only be used with PU Insulation Adhesive – Tin (with ‘water-overmist’) or PU Insulation Adhesive – twin cartridge or mechanically fixed.


Mineral fibre insulation, suitable for projects that require a high level of sound reduction and/ or to be non-combustible; it has a zero GWP and ODP rating.

  • Type: Tapered insulation board.
  • Facing: Top: 300 g/m² glass fibre fleece; bottom: unfaced.
  • Density: 160 kg/m³.
  • Board size: 1200 x 1000 mm.
  • Board thickness (Flatboard): 60 mm, 85 mm, 105 mm, 115 mm, 150 mm, 185 mm (also available in tapered).
  • Thermal conductivity: 0.039 W/m·K (may vary, dependent on thickness specified).
  • Compressive strength: >0.12 N/mm² (minimum 0.08 N/mm²).

Fixing

PU Insulation Adhesive – Tin.

Guidance for specification option:

Not for foil to foil applications (e.g. FA-TE to FA-TE).

PU Insulation Adhesive – Twin cartridge.

Waterproof covering

-

First layer

-

Type

BauderFLEX G4E.

Guidance for specification option:

A 4 mm, heavy-duty, torch-applied elastomeric bitumen underlayer with a strong woven glass reinforcement to provide an extremely high tensile strength.

  • Width: 1 m.
  • Length: 7.5 m.
  • Thickness: 4 mm.
  • Surface finish: Top: mica; bottom: thermofusible polyethylene.
  • Weight: 4.8 kg/m².
  • Tensile strength: ≥1200 N/50mm (length and diagonal).
  • Heat stability: +110°C.
  • Cold bending test: -30°C.
  • Elongation at break: ≥2% (length and diagonal).

Attachment

Torch applied.

Top layer

-

Type

PLANT E.

Guidance for specification option:

A high quality, heavy duty, torch-applied, elastomeric bitumen capping sheet. The product features chemically treated bitumen to deliver superior root resistance which has been tested and approved by the FLL. The membrane is reinforced with 250 g/m² spunbond polyester fleece to allow the finished product to cope with structural movement without fracture. Expandable graphite fire retardant is also incorporated to reduce spread of flame.

  • Width: 1 m.
  • Length: 5 m.
  • Thickness: 5.2 mm.
  • Weight: 6 kg/m².
  • Surface: Top: Green slate mineral chippings; Bottom: Thermofusible polyethylene.
  • Reinforcement: 250 g/m² recycled spunbond polyester.
  • Cold bending test: -36°C.
  • Softening point: >120°C.
  • Tensile strength: Length >1000 N/50 mm; transverse >1000 N/50mm.
  • Elongation at break: Length >45%; transverse >45%.

Attachment

Torch applied.

Detail work

-

Flashings

Not required.

Bauder GRP Trim.

Guidance for specification option:

GRP roof edge trim for use with Bauder bituminous roof systems. Available in colours of either grey or black, and a choice of profiles to suit the requirements of most projects. Consult manufacturer literature and insert requirements.

Bauder GRP Water Check Trim.

Guidance for specification option:

GRP water check trim to be used on parapets and perimeter kerbs wider than 200 mm – must not be used on its own as a check kerb. Available in black only.

Bauder Aluminium Termination Bar.

Guidance for specification option:

Natural finish aluminium alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Bauder GRP Termination Bar.

Guidance for specification option:

Black glass reinforced plastic (GRP) alternative to a lead counterflashing for use at upstand details to give protection to the top edge of the waterproofing. It should be restricted to use on upstands where a chase cannot be cut into the wall.

Skirtings and upstands

Not required.

Bauder LiquiFIBRE Detailing Kit.

Guidance for specification option:

Fast-curing waterproofing resin, containing fibre reinforcement that can be used for detailing awkward shapes or inaccessible areas where using LiquiDETAIL is impractical. PMMA-based resin that requires a catalyst and is solvent, isocyanate and halogen-free.

Bauder LiquiDETAIL.

Guidance for specification option:

Cold liquid applied fast curing waterproofing resin that can be used on upstands and details. PMMA-based resin that requires the addition of catalyst to trigger curing and is solvent, isocyanate and halogen free.

Welted drips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Cover strips

Required.

Guidance for specification option:

Insert requirements.

Not required.

Ancillary items

Required.

Guidance for specification option:

Insert requirements.

Not required.

Surface protection

Not required.

Landscaping options.

Guidance for specification option:

Please refer to Bauder Extensive / Biodiverse / Intensive Landscaping systems.

System accessories

Not required.

Bauder lightning conductors.

Guidance for specification option:

Lightning conductor clips are a specially designed secure clip that allows for movement.

  • Bauder Lightning conductor – Type 4: Polyvinyl chloride (PVC) coated or bare conductor.


Bauder rainwater outlets.

Guidance for specification option:

Bauder has a range of insulated or stainless-steel rainwater outlets.

The insulated outlets can be used for maintaining thermal continuity at drainage points. Suitable for warm, cold and inverted roof construction, the high thermal value of the rigid foam body prevents condensation from forming on the underside of the outlet.

Designed for use when connecting to conventional drainage systems, with excellent flow rate performance and is suitable for both new build and refurbishment projects. Outlets are included in the Bauder waterproofing system guarantee as they are integrated components.

Flow rate figures (where applicable) are based on BS EN 12056:3:2000, typically taken using a 35 mm header of water including leaf grille:

 

  • Bauder Bitumen Compact Vertical Outlet DN100: Insulated internal outlet, 6.1 L/s.
  • Bauder Bitumen Vertical Outlet DN70: Insulated internal outlet, 7.1 L/s.
  • Bauder Bitumen Vertical Outlet DN150: Insulated internal outlet, 7.2 L/s.
  • Bauder Bitumen Letterbox Parapet Outlet DN 205 including stainless-steel leaf guard, 2.02 L/s.
  • Bauder Bitumen Parapet Outlet DN 100 including stainless-steel leaf guard, 1.06 L/s.
  • Bauder Bitumen Vertical Refurb Outlet DN70, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Bitumen Vertical Refurb Outlet DN95, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.
  • Bauder Bitumen Vertical Refurb Outlet DN145, designed to ensure the maximum flow rate of the existing downpipe is not exceeded.

Bauder rooflights/ glazing/ ventilation.

Guidance for specification option:

All these glazing products are fully compatible with the roof waterproofing systems. Consult manufacturer for details and insert requirements.

  • BauderDOME Rooflight.
  • Bauder Euroglaze Rooflight.
  • Bauder Special Modular Rooflight.
  • Bauder Continuous Rooflight.
  • Bauder Walk-on Rooflight.
  • Bauder Direct Glazing.
  • Bauder AOV.
  • Bauder Modular Link Glazing.
  • Bauder Structural Rooflight.
  • Bauder Fire Rated Rooflight.


Sustainability data

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Certificate: Bauder Total Green Roof Systems 10/4744

CCPI System

CCPI System

Bauder BTRS-BTGRS CCPI System Certificate

EPD

EPD

Environmental Product Declaration - Rockwool

EPD

EPD

Environmental Product Declaration - RBM

EPD

EPD

Environmental Product Declaration - FOAMGLAS - EPD-PCE-20200300-IBB1-EN

Literature

Bauder Quick Dry Bitumen Primer - Technical Data Sheet

Bauder Quick Dry Bitumen Primer - Technical Data Sheet

Bauder Super AL-E Roofing membrane

Bauder Super AL-E Roofing membrane

BauderROCK Tapered Insulation

BauderROCK Tapered Insulation

BauderROCK Flatboard Insulation

BauderROCK Flatboard Insulation

Bauder PU Insulation Adhesive - Tin

Bauder PU Insulation Adhesive - Tin

BauderFLEX G4E Roofing membrane - Technical Data Sheet

BauderFLEX G4E Roofing membrane - Technical Data Sheet

BauderPLANT E Roofing membrane

BauderPLANT E Roofing membrane

Bauder LiquiDETAIL

Bauder LiquiDETAIL

Similar products from Bauder Ltd

Bauder System Airtech Warm Roof System - Self Adhered

Bauder System Airtech Warm Roof System - Self Adhered

Bauder Total Green Roof System PLUS Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Green Roof System PLUS Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Green Roof System Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Green Roof System Reinforced Bitumen Membrane Warm Roof Covering System Self-Adhered (with Torch-On Capping Sheet)

Bauder Total Warm Roof System - Self Adhered

Bauder Total Warm Roof System - Self Adhered

Bauder Total Warm Roof System - Torch Applied

Bauder Total Warm Roof System - Torch Applied

Bauder Total Warm Roof System PLUS - Self Adhered

Bauder Total Warm Roof System PLUS - Self Adhered

Bauderflex Green Warm Roof System - Self Adhered (with Torch-On Capping Sheet)

Bauderflex Green Warm Roof System - Self Adhered (with Torch-On Capping Sheet)

Bauderflex Warm Roof System - Self Adhered

Bauderflex Warm Roof System - Self Adhered

Bauderflex Warm Roof System - Torch Applied

Bauderflex Warm Roof System - Torch Applied