Verified by manufacturer 5 months ago
BBA Agrément Certificate
Certificate type
EPD
Certificate type
Elastomer bitumen, torch-on underlayer.
Underlayer in a flat roof system. Can be used adhered to a variety of appropriately prepared substrates and insulants.
Elastomer bitumen, torch-on underlayer.
Only to be used as part of an inverted or uninsulated Bauder Total Roof System on a non-combustible deck.
Color | Black |
Finish | Mica |
Material | Bitumen |
Shape | Rectangle |
Length | 7500 mm |
Width | 1000 mm |
Height | 4 mm |
Uniclass | |
CAWS | J41/120 Built-up reinforced bitumen membrane inverted roof covering J41/130 Built-up reinforced bitumen membrane cold deck roof covering J41/12 Reinforced bitumen membrane cold deck roof covering J41/14 Reinforced bitumen membrane inverted roof covering |
Standard | To BS EN 13707. |
Material | |
Carrier material | Glass fibre.Guidance for specification option: Glass lattice 200 g/m². |
Bitumen modification | Elastomeric. |
Thickness (minimum) | 4 mm. |
Weight (minimum) | 4.8 kg/m². |
Surface finish | |
Top | Mica. |
Underside | Thermofusible polyethylene. |
Colour | Black. |
Third-party certification | BBA certificate 10/4744, EPD S-P-00768. |
Elongation | Length and transverse: ≥2%. |
Width (minimum) | 1000 mm. |
Reaction to fire | Class E. |
Watertightness | Passed. |
TensileStrength | Length and transverse: ≥1200/ 50 N/mm. |
Country of product manufacture | Germany |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0.05 kg CO₂ eq/m² Manufacturer guidancePlease refer to EPD on the Bauder website. EPD data can vary, please ensure that the scope and context of the EPD data is considered when comparing EPD’s for different products. |