Verified by manufacturer 3 months ago
Underfloor heating (UFH) system for use over the floor, pipes held in place by low-profile castellated panels covered with a minimum of 15 mm self-levelling compound.
Underfloor heating (UFH) system for use over the floor, in new builds and renovation.
Underfloor heating (UFH) system for use over the floor, pipes held in place by low-profile castellated panels covered with a self-levelling compound.
Features and benefits:
*Heat output at a flow water temperature of 45°, based on a tog rating of 1 with a room temperature of 21°. Consult manufacturer's literature for full details.
Color | Black |
Finish | Grooved |
Material | Plastic |
Shape | Rectangle |
Length | 1220 mm |
Width | 820 mm |
Height | 12 mm |
Warranty description | Two year Guidance for specification option: Electrical and mechanical products. 50 year Guidance for specification option: Pipes. Manufacturer guidanceConsult manufacturer for full details. |
Uniclass | |
CAWS | T90/475 Underfloor heating systems T90/475 Underfloor heating systems |
System performance | Guidance for specification option: Insert requirements. |
Heat source | Low-temperature hot water heating system.Guidance for specification option: Specify details separately. |
Pumps | Beneath Heat underfloor heating pump pack.Beneath Heat single area pump pack.Manufacturer guidanceConsult manufacturer for details. |
Pipework | |
Distribution | Guidance for specification option: Insert requirements. |
Underfloor | 10 mm PERT pipes and fittings.Manufacturer guidanceInstallation tools available, including pipe decoilers, pipe cutters and pipe calibrators. |
Jointing materials | Guidance for specification option: Insert requirements. |
Pipe supports | Castellated panels plus minimum 15 mm self-levelling compound; pipes at 150 mm centres. |
Valves | Guidance for specification option: Consult manufacturer for options and insert requirements. Options include manifolds, blend valves, heat pump valves and return elbows. |
Water treatment | Guidance for specification option: Consult manufacturer for options and insert requirements or omit. |
Accessories | 230 V Saswell dial thermostat.Guidance for specification option: Consult manufacturer for options and insert requirements. 230 V Saswell programable thermostat.230 V Saswell WiFi thermostat.Wireless Saswell programable thermostat.Wireless Saswell WiFi thermostat.Saswell WiFi gateway |
Controls | |
Controllers | Saswell 230 V two wire actuator.230 V wiring centre.230 V wireless wiring centre. |
Control valves | Saswell two-port motorised valve. |
Sensors | Not required.Saswell floor/ air sensor.Single area pump pack adaptors.Guidance for specification option: Not for use with single area pump pack. |
Floor covering | Tiled. Guidance for specification option: Can be applied directly over the slim board. Specify separately if required. Interlocking wood flooring. Guidance for specification option: Can be applied directly over the slim board. Specify separately if required. Other Guidance for specification option: Minimum 3 mm self-levelling compound required before final covering is applied. Specify separately if required. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Plastic |
Recyclability | Fully recyclable as standard without self adhesive backing |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 99.5 % |