NBS Source
I'm a manufacturer

Blast-resistant stick curtain walling façade system - FW 60+ XR

Verified by manufacturer 5 days ago

Schueco UK Ltd

Blast-resistant façade system.

Jump to:
+44 (0)1908 282111 Website

Application

  • Suitable for military applications as well as for use in high security areas such as petrochemical plants, banks and embassies.
  • For security reasons, fabricators require special approval to construct this system.

Description

Blast-resistant façade system that can withstand a shock wave of 169 kPa generated by an explosion 19 m from the unit (hazard level D “Very low hazard”), as well as meeting all the requirements of standard facades in terms of thermal insulation, sound reduction and weathertightness.


Features and benefits:

  • Tested security in accordance with ISO 16933.
  • Excellent thermal insulation.
  • Extended area of application based on calculations possible.
  • Can be used in combination with blast-resistant Schüco window and door systems.
  • All assemblies to include a Schueco Internet of Facades (IoF) ID tag with unique QR code linked to the product data, ongoing maintenance instructions and installation records creating a project’s digital twin.

General information

Color

Silver

Other

Finish

Powder-coated

Anodized

Material

Aluminium

Glass

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_10_20_85 Stick curtain walling systemsPrimary

CAWS

H11/110 Curtain walling

Specification data - Stick curtain walling systems

Framing

-

Frame members

Aluminium curtain wall frame sections, polyester powder-coated.

Guidance for specification option:

Insert colour requirements.

Aluminium curtain wall frame sections, anodized.

Frame accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements, or omit.

Fasteners

Manufacturer's standard.

Cladding units

-

Glass units

-

Manufacturer guidance

Insert requirements including thickness (24–44 mm).

Glazing accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements, or omit.

Panels and facings

-

Material

Aluminium.

Fasteners

Manufacturer's standard.

Perimeter seals

Manufacturer's standard.

System accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements, or omit.

Face width

60 mm.

Guidance for specification option:

Minimum.

Thermal transmittance (U-Value)

-

Manufacturer guidance

Insert requirements or consult manufacturer for values.

Uf value of frame: ≥ 1.3 W/m²K.

Burglar resistance

-

Manufacturer guidance

Insert requirements, up to RC 2.

Air permeability

Class AE.

Watertightness

Class RE 1200.

Resistance to wind load

2.0/ 3.0 kN/m².

Blast resistance

In accordance with ISO 16933.

Guidance for specification option:

Consult manufacturer.

Label

Schueco ‘IoF’ ID tag with QR code.

Guidance for specification option:

Internet of facades (IoF) ID tag with unique QR code linked to the product data, ongoing maintenance instructions and installation records.

Sustainability data

Country of material origin

United Kingdom