Verified by manufacturer 8 months ago
Cost-efficient vehicle transport between floors.
Car lift; applications include single-family detached homes, multi-family buildings, office buildings and hotels. Suited to less frequent traffic; particularly suitable for up to 26 parking places.
Cost-efficient vehicle transport between floors.
Features and benefits:
Technical data:
Color | Other Guidance for specification option: Contact manufacturer for any colour. |
Finish | Galvanized |
Material | Steel |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | One year |
Uniclass | |
CAWS | X12/110 Vertical lifting platform systems X12/110 Vertical lifting platform systems |
Standard | Machine Directive 2006/42/EC and DIN EN 81-41 (on the basis)Guidance for specification option: To Machinery Directive 2006/42/EC. |
Rated load (minimum) | 3500 kg.Guidance for specification option: Maximum 4200 kg. Manufacturer guidanceAxle load: Maximum 1750 kg, forklift operation prohibited. |
Drive type | Hydraulic power unit with pump-motor suboil unit.Guidance for specification option: See Motor Position below for machine room/ cabinet options. |
Carriage type | Fully enclosed. |
Carrier | |
Frame material | Manufacturer's standard. |
Frame finish | Manufacturer's standard. |
Frame colour | Manufacturer's standard. |
Infill material | Sheet steel. |
Infill finish | Sendzimir-galvanized steel.Painted.Stainless steel. |
Insert colour | Silver.Guidance for specification option: Standard for Sendzimir-galvanized and stainless steel finishes. Colour.Guidance for specification option: Painted finish only; insert requirements. |
Doors | |
Arrangement | Front opening (single entrance).Through-loading/ front-and-rear opening (two entrances). |
Type | Six-part, centrally opening telescopic sliding doors.Guidance for specification option: Standard. Automatic louvre doors, centrally opening.Two cabin/ two landing doors.Guidance for specification option: Slat-surface aluminum, powder-coated RAL 9006. Manufacturer guidanceDoor height is 2100 mm as standard; for options, consult manufacturer. |
Clear opening width (minimum) | Manufacturer guidanceInsert requirements, maximum door width: 2400–3000 mm. Maximum cabin width varies dependent on maximum door width and lifting height required; consult manufacturer's literature for details. |
Fire classification | Manufacturer's standard.EW30.Guidance for specification option: Only available with standard telescopic doors. EW60.Guidance for specification option: Only available with standard telescopic doors. |
Frame material | Low-carbon steel. |
Frame finish | Painted. |
Infill finish | Manufacturer's standard.Painted.Powder-coated. |
Infill colour | Manufacturer's standard.Guidance for specification option: Manufacturer's standard finish only. RAL.Guidance for specification option: Insert requirements from the Classic RAL colour table. Available for painted or powder-coated finishes only. |
Carrier floor | |
Dimensions | |
Width (minimum) | Manufacturer guidanceConsult manufacturer's literature and insert requirements. 2500–3000 mm ;maximum cabin width allowable varies dependent on maximum door width and lifting height required. |
Depth (minimum) | Manufacturer guidance5500–7000 mm.; consult manufacturer's literature and insert requirements. Cabin depth is defined as the distance between the entrance panels. Useable depth depends on door arrangement:
|
Material | Extruded aluminium profiles.Guidance for specification option: Particularly suitable for difficult construction site situations with regard to space conditions, as this variant is only installed in the lift shaft on site. Smooth sheet metal, primed.Guidance for specification option: RAL 7032. Smooth sheet metal, primed, platform division.Guidance for specification option: RAL 7032. Aluminium bulb plate.Aluminium bulb plate, platform division.V2A stainless steel chequer plate.V2A stainless steel chequer plate, platform division.Two-component anti-slip coating.Guidance for specification option: Epoxy resin-based, solvent-free and non-slip coating, is sprinkled with quartz sand with a grain size of 0.3–0.8 mm. Two-component anti-slip coating, platform division.Manufacturer guidanceOn request, a platform division can be made in longitudinal direction. This is particularly recommended in difficult construction site situations, with regard to space conditions, in order to ensure the insertion of the platform into the lift shaft. Not available/required for extruded aluminum profiles. |
Colour | As Material. |
Electrical supply | Manufacturer's standard. |
Control device type | Manufacturer's standard.Guidance for specification option:
Manufacturer guidanceOperation via smartphone app is available; consult manufacturer for details. |
Accessories | None.Deflector rails, hardwood.Guidance for specification option: Insert requirements. Can be arranged on the car side walls in a single row or two-row arrangement. This prevents damage to the lift cabin and vehicle. Deflector rails, plastic.Guidance for specification option: Insert requirements. Can be arranged on the car side walls in a single row or two-row arrangement. This prevents damage to the lift cabin and vehicle. Threshold heating tape.Guidance for specification option: Self-limiting heating tape for landing door thresholds located outdoors for safe operation of the lift system in frosty conditions. Silence package I.Guidance for specification option: For the reduction of structure-borne noise on the hydraulic drive system. Consult manufacturer for details. Silence package II.Guidance for specification option: For the reduction of structure-borne noise on the hydraulic drive system. Consult manufacturer for details. Silence package III.Guidance for specification option: Whisper rollers for telescopic sliding door. Consult manufacturer for details. Key safe.Guidance for specification option: Complete key safe with three keys, security card: Series 600 834 EFEFBF and wall anchor. Outer dimensions: 145 x 46 mm; internal dimensions: 78 x 36 mm. To be installed on site independent of the lift. Manufacturer guidanceAdditional features not listed, e.g. oil coolers or tank heaters, are dependent on performance requirements and can be discussed with the manufacturer. |
Entry configuration | One side or through car loading Manufacturer guidanceInsert requirements, 2–8 stops. Include details of accesses per floor for through-loading/ front-and-rear opening. |
Cabin | Guidance for specification option: Height: 2100–3000 mm; insert requirements. Manufacturer guidanceComponents:
For full details, consult manufacturer. For deflector strips, see Accessories. |
Lift height | up to 25,000 mm Manufacturer guidanceUp to 25 000 mm; insert requirements. For cabin heights of 2100 mm and superimposed accesses, the minimum floor distance is 2670 mm. Note that allowable cabin, shaft and door widths vary with overall lifting height. Consult manufacturer's literature for details. Lifting height is the distance between the finished floor level (FFL) of the highest and lowest levels. Pit depth and headroom at the highest level are additional height factors. |
Headroom | Manufacturer's standard. Guidance for specification option: Consult manufacturer's literature for details. Bespoke. Guidance for specification option: Consult manufacturer's literature for options and insert requirements. Manufacturer guidanceNote that the headroom depends on a number of factors, including the planned pit, and can increase in size if a silence package is used (see accessories). |
Shaft | Manufacturer's standard. Guidance for specification option: Width/ depth = cabin width/ depth + 800 mm. Head height minimum 2700 mm (dependent on headroom requirements. Bespoke. Guidance for specification option: Insert requirements.
Consult manufacturer's literature for details. |
MotorPosition | Machine room (option 1). Guidance for specification option: Minimum width: 2000 mm. Minimum depth: 2000 mm. Machine room (option 2). Guidance for specification option: Minimum width: 1400 mm. Minimum depth: 3000 mm. Machine room (option 3). Guidance for specification option: Minimum width: 450 mm. Minimum depth: 2560 mm. Machine control cabinet (option 4). Guidance for specification option: Minimum width: 700 mm. Minimum depth: 1400 mm. A space-saving version of the machine room. The drive unit and control unit are housed in the cabinet, removing the need for a separate machine room (saves approx. 4 –5 m²). Machine control cabinet (option 5). Guidance for specification option: Minimum width: 700 mm. Minimum depth: 1400 mm. A space-saving version of the machine room, recessed into the shaft wall to avoid a protruding contour outside the shaft. Manufacturer guidanceFor all options, insert location requirements.
Minimum height: 2100 mm. |
Pit opening | Depth: 850 mm. Guidance for specification option: As standard. Depth reduction possible; consult manufacturer. |
Speed | 0.15 m/s. |
Insulation | Not required. Option 1: non-continuous insulation in door area. Option 2: Continuous insulation. Manufacturer guidanceThe following areas can be insulated:
Consult manufacturer for full details including allowable insulation thicknesses. |
Contains Red List materials | No |
Country of material origin | Germany |
Country of product manufacture | Germany |