Verified by manufacturer 5 months ago
A1 Natural Contour Groove
Complete system specification for Ceramapanel and Vitrafix, plus fixings to the wall from Certifix.
Particularly suited to both internal and external modern commercial, residential and industrial buildings, where a natural facade is needed.
4.8 mm-diameter Vitrafix colour-matched, large flange Vitrafix rivets fixed to Vitrafix VF1 system. Fixings should be spaced 45–65 mm from edge measured with the fibres and 25–50 mm from edge measured across the fibres.
When using Vitrafix rivets, ensure that a VFNPR/16/F Vitrafix rivet nosepiece adapter is also used to prevent over-tightening of the Vitrafix rivets. Once both fixed points are installed, work over the panel for the sliding centres – consult manufacturers drawings for further details.
A complete system specification for Ceramapanel and Vitrafix, plus fixings to the wall from Certifix (in partnership with Valcan). This provides a comprehensive warranty on the complete system. All Certifix provided products are tested and certified in accordance with ADB v2 for high rise buildings.
All batch numbers will be recorded, regular site visits to be made by Valcan and Certifix during the installation, frequency to be decided at order stage with client.
Ceramapanel:
A through-coloured, compressed fibre-cement facade panel available in 8, 10 or 12 mm thicknesses, in A1 rating as required. It is both an aesthetically appealing and cost-effective cladding solution offering a natural appearance. It also has good acoustic dampening properties.
Features and benefits:
Ceramapanel technical characteristics:
Durability:
The cement panel is highly durable and includes immunity to permanent water damage in both short and long-term exposure. It will not rot, burn or corrode and is unaffected by termites, air, steam, salt and sunlight. It is not adversely affected over a temperature range of -20 to +60°C.
Vitrafix systems:
Aluminium carrier system brackets, profiles and fixings which have been tested to BS 8414-1 and BS 8414-2 and are Centre for Window and Cladding Technology (CWCT) tested. Designed to offer a cost effective yet strong carrier system, and is suitable for all building types.
Features and benefits:
Color | Beige Black Blue Brown Green |
Finish | Smooth Textured Painted |
Material | Fibre cement |
Warranty description | 15 year Guidance for specification option: Ceramapanel. Manufacturer guidanceSystem warranty available - contact manufacturer's technical team for information |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
System performance | Manufacturer guidanceInsert requirements. |
Thermal insulation | Certifix mineral wool rainscreen slab, thickness.Guidance for specification option: Insert required thickness. Thermal performance: 0.034 W/m·K. Fire rating (to BS EN 13501-1): A1. Fixings: CIA/FR Certifix fire-rated insulation fixings. |
Breather membrane | |
Material | CFA1BM CertiShield Class A2 Breather Membrane.Guidance for specification option: Fire performance (to BS EN 13501-1): A1. |
Fasteners | Manufacturer's standard. |
Secondary support structure | Vitrafix VF1.Manufacturer guidanceSee below for options for: Brackets; rails; horizontal rails; fixings; accessories. |
Cavity fire barriers | |
Horizontal | Certifix VRFB+ open state horizontal barrier.Manufacturer guidanceFixings: Fire-tested fixings to be advised by Certifix Ltd to equivalent performance of fire barrier, fixing reference dictated by substrate. |
Vertical | Certifix NVRFB non-ventilated vertical barrier.Manufacturer guidanceFixings: Fire-tested fixings to be advised by Certifix Ltd to equivalent performance of fire barrier, fixing reference dictated by substrate. |
Cladding panels | |
Material | Ceramapanel through-coloured fibre cement panel, 2500 x 1250 x 8 mm.Guidance for specification option: Weight: 14.4 kg/m². Ceramapanel through-coloured fibre cement panel, 3050 x 1250 x 8 mm.Guidance for specification option: Weight: 14.4 kg/m². Ceramapanel through-coloured fibre cement panel, 2500 x 1250 x 10 mm.Guidance for specification option: Weight: 18.0 kg/m². Ceramapanel through-coloured fibre cement panel, 3050 x 1250 x 10 mm.Guidance for specification option: Weight: 18.0 kg/m². Ceramapanel through-coloured fibre cement panel, 2500 x 1250 x 12 mm.Guidance for specification option: Weight: 21.6 kg/m². Ceramapanel through-coloured fibre cement panel, 3050 x 1250 x 12 mm.Guidance for specification option: Weight: 21.6 kg/m². Manufacturer guidanceSee product description for technical characteristics. |
Panel joints | 8–10 mm open joints.CFBB/65 Certifix Birdsbeak joint closure profile.Guidance for specification option: 65 mm wide, 0.8 mm thick. Vitrafix EPDM self-adhesive rail tape, (1 mm thick) must be used when using birdsbeak closure profiles; specify in Accessories. CFVM Certifix Vermin closure profile.Guidance for specification option: Depth to suit project cavity. |
Reveals | Not required.25 mm-wide window flashing profile. |
Colour/ Finish | 1121 Sky Blue. 1011 Rain Cloud. 1021 Light Slate. 1091 Cappuccino. 1001 Bleached Cotton. Manufacturer guidanceThe panel features 2 mm-deep grooves spaced 20 mm apart. Custom spacing is available according to design intent – contact manufacturer for details. |
Fire rating (to BS EN 13501) | A1. |
Brackets | VF100DB 100 mm double bracket (no pad). Guidance for specification option: 102–132 mm adjustment. VF100SB 100 mm single bracket (no pad). Guidance for specification option: 102–132 mm adjustment. VF140DB 140 mm double bracket (no pad). Guidance for specification option: 142–172 mm adjustment. VF140SB 140 mm single bracket (no pad). Guidance for specification option: 142–172 mm adjustment. VF180DB 180 mm double bracket (no pad). Guidance for specification option: 182–212 mm adjustment. |
Rails | VFTR503 T-rail, 50 x 100 x 3000 mm. VFTR506 T-rail, 50 x 100 x 6000 mm. VFLR503 L-rail, 50 x 100 x 3000 mm. VFLR506 L-rail, 50 x 100 x 6000 mm. |
Horizontal Rails | Vitrafix VF2/U 90 x 15 x 2 mm. Guidance for specification option: Length: 3000 mm. Vitrafix VF2/U 174 x 15 x 2 mm. Guidance for specification option: Length: 3000 mm. Not required. Guidance for specification option: Not required for masonry walls. Manufacturer guidanceVF2/U attached to SFS locations allowing brackets to be installed in isolation to stud location. Fixing to stud: VFSD.538/A4 – Vitrafix self-drill, A4 grade 5.5 x 38 mm, 8 mm hex head w/washer – consult manufacturer's details for fixing centres. |
Fixings | VFSD4.825/A4 Vitrafix self-drill, 4.8 x 25 mm, A4 grade, 8 mm hex head. VFSD.538/A4 Vitrafix self-drill, 5.5 x 38 mm, A4 grade, 8 mm hex head w/washer. Masonry anchors by Certifix Ltd - ETA approved, fire-rated fixing. VFR4.820A4C Vitrafix Rivet, 4.8 x 20 mm A4 Grade, 16 mm Head, Colour Matched to Panel (5-13 mm grip range). |
Accessories | None. VFIPDB Double bracket thermal pad. Guidance for specification option: Adds 3 mm adjustment. VFIPSB Single bracket thermal pad. Guidance for specification option: Adds 3 mm adjustment. VFRT55/1.0 Vitrafix EPDM self-adhesive rail tape, 55 x 1 mm. Guidance for specification option: Length: 20 m. VFRT105/1.0 Vitrafix EPDM self-adhesive rail tape, 105 x 1 mm. Guidance for specification option: Length: 20 m. |
Cavity | Depth: 50 mm open joint installation. Guidance for specification option: Measured from face of insulation to rear of panel, can be reduced by 50% at fire barrier locations or other “pinch” points. Depth: 25 mm closed joint installation. Guidance for specification option: Measured from face of insulation to rear of panel, can be reduced by 50% at fire barrier locations or other “pinch” points. Other. Guidance for specification option: Consult CWCT section 3.4.4.4 and insert requirements. |
Flashing | Not required. 25 mm-wide window flashing profile. |
Sheathing board | ProcellaPro. Guidance for specification option:
|
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
Ceramapanel & VitraFix Secret Fix Non-Combustible A1 Cladding System
Ceramapanel – Fibre Cement Non-Combustible A1 Cladding Panels
Evverlap A2 Fibre Cement VF1 Cladding System
Evverlap A2 Fibre Cement VF2 Cladding System
VitraDual - Non Combustible A1 Cassette Fix Cladding System
VitraDual - Non-Combustible A1 Aluminium Cladding Panel
VitraDual A1 Non-combustible Planking System Fix
VitraDual A1 Non-combustible Rivet Fix Cladding System