Verified by manufacturer 4 months ago
Double leaf
BRE Certificate
Certificate type
Swing gate system to LPS 1175 D10 (SR4)/E3/G1 Issue 8.
CLD LockMaster S4 swing gates have been specially developed to blend in with a CLD Securus fence line. Available using a Securus S4 infill panel, LockMaster S4 offers security rated access control, whilst maintaining aesthetics. Tested by the Loss Prevention Certification Board (LPCB) to guarantee a minimum delay of ten minutes against attack. LockMaster S4 is also Secured by Design accredited, making it a police preferred specification for security.
Features and benefits:
Color | Other Guidance for specification option: Any RAL colour. |
Finish | Powder-coated Galvanized |
Material | Steel |
Shape | Rectangle |
Width | Bespoke Guidance for specification option: To suit mesh infill panels: Single leaf: 900–2500 mm. Double leaf: 1200– 8000 mm. |
Height | Bespoke Guidance for specification option: 2800–5000 mm to match fence panel. Single leaf gates always have lintel panel. |
Warranty description | One year Guidance for specification option: Auto-element: Minimum of 12 months. 15 year Guidance for specification option: Minimum of 15 years against manufacturing defects. |
Uniclass | |
CAWS | Q40/45 Gates Q40/570 Gates |
Standard | To BS 1722-14. |
Dimensions | |
Span | Manufacturer guidanceTo suit mesh infill panels: Double leaf: 1200–8000 mm. Insert requirements. |
Height | Manufacturer guidance2800–5000 mm to match fence panel. Single leaf gates always have lintel panel. Insert requirements. |
Posts | Steel.Guidance for specification option: Post dimensions: 50 x 150 mm minimum. |
Gate leaves | Panel infill to match CLD Securus S4. |
Hardware | |
Hinges | 3 no. Superhinge SH30. |
Securing | Slide bar with certified padlock. |
Finish as delivered | |
Applied finish | Polyester powder-coated to 60-80 microns.Polyester powder-coated to 160-200 microns.Guidance for specification option: With marine grade and metallics. |
Colour and finish | RAL colour. Guidance for specification option: Any RAL colour available, insert requirements. |
Configuration | Double leaf, opening inwards. Double leaf, opening outwards. |
Post foundations | Posts baseplated and fixed with M20 (minimum) anchors in suitable concrete foundation 100 mm below finish ground level. Guidance for specification option: The manufacturer advises that the contractor/ client is responsible for the foundation size suitable for the ground conditions. |
SecurityRating | LPS 1175 D10 (SR4)/E3/G1 Issue 8. |
Frame | Vertical stiles/ horizontal rails (minimum): 100 x 50 x 3 mm rectangular hollow section. Guidance for specification option: To suit mesh infill panels. Galvanized and powder-coated to match fencing. |
Topping | Saw tooth topping. Barbed wire, cranked. Barbed wire, straight. Razor wire, cranked. Razor wire, straight. |
Country of product manufacture | United Kingdom |