NBS Source
I'm a manufacturer
Compare variants

Corrugated / Sinusoidal (19mm Deep) Profile Roof System - AP18HR-R - Sinusoidal Roof Profile System

Verified by manufacturer 3 months ago

Steel profiled sheets

Architectural Profiles Ltd Variant:

Sinusoidal roof profile.

Jump to:
+44 (0)118 927 2424 Website

Application

Roof profiles that can be used to reproduce original profiled roofing shapes, or modern, bolder alternatives.

Applications include: Educational facilities, commercial premises, offices and manufacturing facilities.

Description

Sinusoidal roof profile.


Features and benefits:

  • Matching wall system available (specified separately).
  • Available in aluminium, steel or Cor-Ten in a range of finishes:
  • Aluminium: PPC, Armacoil™ HDP, anodized, Stucco-Embossed Mill-Finish (SEMF) and Smooth Mill Finish (MF).
  • Steel: APL PUF, PRISMA, PPC, LeatherGrain (LG) Plastisol and plain galvanized finishes.
  • Cor-Ten: Unweathered.
  • A1 fire-rated materials available.
  • Available as acoustic construction with enhanced acoustic performance.
  • Available with coating warranties up to 40 years including in marine environments.
  • Available perforated and in bespoke lengths.
  • 35 years’ experience of these specialized profiles.
  • Also available as a wider profile (45HR-R; specified separately).


System components:

  • Liner sheet.
  • Subframe (dependent on performance).
  • Profiles and flashings.

General information

Color

Silver

Guidance for specification option:

Aluminium or steel.

Other

Guidance for specification option:

Standard and bespoke/ special colours available.

Manufacturer guidance

Aluminium / Steel: Standard RAL Range; Contact APL for full details; Bespoke upon request

Cor-Ten: Unweathered.

Finish

Powder-coated

Guidance for specification option:

Class 1 or Class 2

Full RAL colour range and / or contact

APL for additional finishes such as anodised-look

Anodized

Guidance for specification option:

Contact APL for details

Natural

Guidance for specification option:

Smooth mill-finish aluminium

Unweathered Cor-Ten

Embossed

Guidance for specification option:

Stucco-embossed mill-finish aluminium or Armacoil™ HDP (Subject to minimum quantity)

Painted

Guidance for specification option:

Aluminium with Armacoil™ HDP (Subject to minimum quantity)

Steel with APL PUF, PRISMA or Leathergrain Plastisol

Manufacturer guidance

PPC, Armacoil™ HDP, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF). PRISMA, Leathergrain Plastisol, Natural

Material

Aluminium

Steel

Cor-Ten

Shape

Other

Guidance for specification option:

Sinusoidal, corrugated.

Manufacturer guidance

Sinusoidal, corrugated

Length

Bespoke

Width

990 mm

Guidance for specification option:

Cover width.

Height

19 mm

Warranty description

25 year

Guidance for specification option:

Cladshield™ fully-installed system warranty available; consult manufacturer for details.

Uniclass

Ss_30_40_65_50 Metal profiled sheet self-supporting roof covering systemsPrimary

CAWS

H31/120 Metal

H31/10 Metal

Specification data - Metal profiled sheet self-supporting roof covering systems

System performance

-

Manufacturer guidance

Insert requirements.

Liner sheets

-

Material

AP22 HWR profile in 0.7 mm steel - solid, off white 80F.

AP22 HWR profile in 0.7 mm steel - fully perforated, off white 80F.

Guidance for specification option:

Consult manufacturer for details of perforation size.

AP22 HWR profile in 0.7 mm steel - web perforated, off white 80F.

Guidance for specification option:

Consult manufacturer for details of perforation size.

AP31/1000 LP profile in 0.7 mm steel - solid, off white 80F.

AP31/1000 LP profile in 0.7 mm steel - fully perforated, off white 80F.

Guidance for specification option:

Consult manufacturer for details of perforation size.

Primary fasteners

Manufacturer's standard.

End and side laps

Minimum 100 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT side lap sealant range, P152 Flute Fillers.

Air and vapour control layer

-

Material

Standard: AP22HWR Liner sheet.

Acoustic: Reinforced VCL laid over stirrup (P016).

Guidance for specification option:

Consult manufacturer for details.

Fasteners

APL P191/HH fixing range.

Other.

Guidance for specification option:

Insert requirements.

Sealing

APL P191/HH fixing range (side laps sealed with 2x runs of P108/VCT).

Other.

Guidance for specification option:

Insert requirements.

Spacers

Standard.

Guidance for specification option:

Components:

  • P665 RWB;
  • P030 Ventilated Zed with P601 structural splice as required;
  • P151 Clamp Endlap Angle;
  • P647 ridge restraint strap required when pitch >7º and/ or cavity >200 mm.

Use P912/BT50 isolating tape to top face of P030.

Acoustic.

Guidance for specification option:

Components:

  • P016 Stirrup;
  • P665 RWB;
  • P030 Ventilated Zed with P601 structural splice as required;
  • P151 Clamp Endlap Angle;
  • P647 ridge restraint strap required when pitch >7º and/ or cavity >200 mm.

Use P912/BT50 isolating tape to top face of P030.

Manufacturer guidance

Consult manufacturer for details and insert further requirements if applicable.


Fixings: APL P191/HH fixing range as standard.

Acoustic insulation

A1-rated with thickness and performance specification as required to meet performance.

Guidance for specification option:

Contact manufacturer for details and insert details as required.

Thermal insulation

A1-rated.

Guidance for specification option:

Insert requirements; A1-rated, thickness as required to meet U-value requirement with minimum lambda of 0.040 for all calculation purposes;

Allow an additional minimum of 10% of the cavity depth of soft-type insulation for compression to allow insulation to fill profile corrugations.


Refer to the relevant U-value table in the supporting literature.

External sheets

-

Material

18HR-R steel profiled sheets.

Manufacturer guidance

Cover width: 990 mm (standard), 914 mm (on roof pitch less than 10º).

Profile width: 166.67 mm; height: 19 mm.

0.7 mm nominal thickness.

Primary fasteners

APL 191/LP fixing range, colour matched as required: valley fix at every corrugation at end laps and every other corrugation elsewhere.

Secondary fixings

APL 191/LP fixing range, colour matched as required.

End and side laps

End laps: 150 mm; APL 191/LP fixing range, colour matched as required; side laps stitched at maximum 400 mm centres; APL P103 sealant for side laps (2no runs) and end laps (3no runs); APL P152/HP Flute Fillers.

Fascia

-

Material

APL Slimwall™ CPS/SSF Discreet Fix system.

Guidance for specification option:

To be specified separately.

Cross-refer to fascia system as required.

Soffit

-

Material

APL Soffit Systems - AP 22/50-S profile.

Guidance for specification option:

Aluminium, steel and Cor-Ten available.

APL Soffit Systems - SFP24-S profile.

Guidance for specification option:

Aluminium only.

APL Soffit Systems - SFP42-S profile.

Guidance for specification option:

Aluminium only.

APL Soffit Systems - CPS-SSF-S profile.

Guidance for specification option:

Aluminium only.

Manufacturer guidance

To be specified separately as a variant under APL Soffit Systems or omitted as required. See that system for full details, including solid/ perforated options (varies with material specified).

 

Cross-refer to soffit system as required.

Gutters

-

Material

-

Manufacturer guidance

Contact manufacturer for Eavesline Gutter information; insert details or omit as required.

Glazing

Required.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Not required.

System accessories

APL System Flashings.

APL Fixings (P191 & P192).

APL Sealants & P152 profile flute fillers.

Guidance for specification option:

As manufacturer's recommendations and to match profiles.

Colour/ Finish

APL PUF.

Guidance for specification option:

Insert colour required.


Colorcoat® PRISMA®.

Guidance for specification option:

Insert colour required.


LeatherGrain Plastisol.

Guidance for specification option:

Insert colour required.


Natural galvanized steel.

Polyester powder-coating, class 1.

Guidance for specification option:

Insert colour/ finish required.


Show more

Manufacturer guidance

Insert colour requirements.

Recycled content (minimum)

85%.

Liner Supports

Guidance for specification option:

Subject to loadings.

Centres are to general areas only, closer at high load zones.


Purlins at maximum 1400 mm centres in general areas, closer at high load zone/corners.


Profile supports

-

Manufacturer guidance

Subject to loadings. Centres are to general areas only, closer at high load zones.


To general areas: P665 brackets at maximum 1500 mm centres along each purlin, P030 fixed to every bracket; closer at high load zones/corners.

Minimum bearing area

50 mm.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Recyclability

High

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

%

Guidance for specification option:

Subject to substrate (steel or aluminium) and grade of aluminium

Literature

AP18HR - Aluminium - Roofing Data Sheet

AP18HR - Aluminium - Roofing Data Sheet

AP18HR - Steel - Roofing Data Sheet

AP18HR - Steel - Roofing Data Sheet

APL Liner Profiles - Roofing & Cladding - Data Sheet

APL Liner Profiles - Roofing & Cladding - Data Sheet

APL Liner Profiles - Roofing & Cladding - System Summary

APL Liner Profiles - Roofing & Cladding - System Summary

APL Tritherm Spacer System - Roofing - System Summary

APL Tritherm Spacer System - Roofing - System Summary

APL Tritherm Spacer System℗ - STEEL - Data Sheet

APL Tritherm Spacer System℗ - STEEL - Data Sheet

U-Values + Build Up - Roof - Pierce Fix

U-Values + Build Up - Roof - Pierce Fix

APL Armacoil™HDP + HDP-HT - Product Brochure

APL Armacoil™HDP + HDP-HT - Product Brochure

APL Roofing - Sinusoidal Profiles - System Summary

APL Roofing - Sinusoidal Profiles - System Summary

APL Roof Systems - System Brochure

APL Roof Systems - System Brochure

APL SoundRoof™ and SoundWall™ - System Summary

APL SoundRoof™ and SoundWall™ - System Summary