Verified by manufacturer 7 months ago
Three-phase mains power supply (400 V): 9 kW
Bosch Compress 5800i Wall-hung Heat Pump Indoor Unit.
Suitable for wall-hung indoor applications.
The Bosch Compress 5800i Wall-hung Indoor Unit is one of three possible indoor solutions to be paired with the Bosch Compress 5800i AW heat pump. The wall-hung option provides flexibility for third-party system solutions where the DHW tower or pre-plumbed cylinder maybe not be suitable such as in a case where a higher domestic hot water volume is required. Easy to install the wall-hung unit has the premium look and feel design of the heat pump itself and comes with integrated space and DHW back-up heater, full-colour touch HMI800 display, three-way valve and primary circulation pump.
Features and benefits:
Color | White |
Finish | Semi-gloss |
Material | Metal |
Shape | Rectangle |
Length | 297.0 mm |
Width | 400.0 mm |
Height | 719.6 mm |
Warranty description | Seven year |
Uniclass | |
CAWS | T90/505 Air-to-water heat pumps T90/505 Air-to-water heat pumps |
Description | Wall-hung heat pump indoor unit. |
Manufacturer | Bosch Thermotechnology Ltd. |
Standards | |
Safety and environmental | To BS EN 378-1 and BS EN 378-2. |
Electrical safety | To BS EN 60335-2-40. |
Heat pump type | Exhaust. |
Mode | Cooling and heating. |
Output | |
Heating | 9 kW. |
Electrical supply type | Three phase. |
Accessories | Not required.DHW cylinder (water heater).Automatic air ventilation valve for the DHW cylinder.Thermostatic valve hot water.Pressure relief valve DHW.DHW circulation pump.Filling equipment DHW.Incoming cold water check valve.Room controller.Connect-Key K30RF.Safety thermostat for under floor heating.Manufacturer guidanceOptional - the following accessories can be added on and are not required for operation of the system. |
Refrigerant | R290. |
Dimensions | 400 x 719.6 x 297.0 mm. |
Connection | ∅28 mm. Manufacturer guidanceConnection heating (flow and return). Connection heat pump (flow and return). |
Operating pressure (maximum) | 300 kPa/ 3 bar. Guidance for specification option: Minimum: 70 kPa/ 0.7 bar. |
SupplyWaterTemperatureHeating | 75℃. Guidance for specification option: Minimum water temperature (if cooling is available): 7℃. Manufacturer guidanceMaximum water temperature (flow), booster heater only. |
Ingress protection (IP) rating | IPX4D. |
Weight | 26 kg. |
Installation height | Up to 2000 mm. Guidance for specification option: Above sea level. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Metal |