NBS Source
I'm a manufacturer
Compare variants

Description

A flow measurement device.


D901 Flow Measurement Device is suitable for systems where pipes have been sized on the basis that pipe frictional losses lie in the range 100 to 400 Pa/m.


D902 Flow Measurement Device (1/2"/15 mm size only) is suitable for the measurement of ultra-low flows in the range 0.015 to 0.06 L/sec e.g. flows to fan coil units.


Features and benefits:


  • Square edged entrance orifice plates with tappings for P84 insertion style test points.
  • Flow measurement accuracy of ±5%.

General information

Color

Yellow

Material

DZR brass

Uniclass

Pr_65_54_95_30 Flow-measuring valvesPrimary

Specification data - Flow-measuring valves

Standard

To BS 7350: 1990, BS EN 10226, BS EN 1254/2, BS EN 12165 and BS EN 12164.

Material

DZR copper alloy.

Connections

Pressure-tight joints threaded to BS EN 10226-1 and compression to BS EN 1254-2.

Inlets/outlets diameter

20 mm.

Dimensions

58 x 61 mm.

Weight

0.3 kg.

Approvals

Water Regulations Advisory Scheme (WRAS).

PressureRange

Temperature (Threaded): -10 to +100°C: 25 bar, Temperature (Threaded): +110°C: 23.4 bar, Temperature (Threaded): +120°C: 21.8 bar. Temperature (Compression): -10 to +30°C: 16 bar, Temperature (Compression): +65°C: 10 bar, Temperature (Compression):+120°C: 5 bar. Maximum temperature 120°C. WRAS Approved Product to 99°C.

Flow capacity

6.1 Kv and 4.7 Kvs.

Guidance for specification option:

Headloss (K): 9.1.