Verified by manufacturer 3 months ago
ETBH12E6V + EPRA08EV3
Mid-temperature, low capacity air-to-water heat pump.
Suitable for use in domestic applications.
A mid temperature air-to-water heat pump for heating, cooling and domestic hot water. The outdoor unit can be used in combination with multiple indoor units, with wall mounted and free standing options that are designed to blend in with other household appliances.
Features both an indoor and outdoor unit.
Features and benefits:
For full technical information, consult manufacturer's literature.
Components:
Color | Silver Black White Manufacturer guidance
|
Material | Steel Guidance for specification option: Polyester painted galvanised steel plate (EPRA08-12DV3). Resin Guidance for specification option: Resin sheet material (ETBH12E6V, ETBH12E9W, ETBX12E6V and ETBX12E9W). |
Shape | Rectangle |
Length | Manufacturer guidanceDependent on unit specified, see specification data for details. |
Width | Manufacturer guidanceDependent on unit specified, see specification data for details. |
Height | Manufacturer guidanceDependent on unit specified, see specification data for details. |
Warranty description | Five year |
Uniclass | |
CAWS | T90/505 Air-to-water heat pumps T90/505 Air-to-water heat pumps |
Standards | |
Test requirements | To BS EN 14511. |
Heat pump type | Split. |
Mode | Heating. |
Coefficient of performance (minimum) | 4.92 kW.Guidance for specification option: Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). |
Output | |
Heating | 6.17 kW (nominal).Guidance for specification option: Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). |
Fan | |
Type | Propeller. |
Fan drive | Direct. |
Configuration | Horizontal. |
Electrical supply type | Single phase.Guidance for specification option: 230 V/ 50 Hz. |
Compressor | |
Type | Swing. |
Sealing | Hermetically sealed. |
Drive | Inverter driven. |
Accessories | Not required.Daikin Residential Controller. |
Refrigerant | R32.Guidance for specification option:
|
Unit dimensions | 1003 x 1270 x 533 mm (EPRA08EV3); 840 x 440 x 390 mm (ETBH12E6V). Manufacturer guidanceHeight x width x depth. |
Unit weight | 118 kg (EPRA08EV3); 36.5 kg (ETBH12E6V). |
HeatingWaterFlowRate | 18.3 L/min. Guidance for specification option: Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C). Manufacturer guidanceWater side heat exchanger water flow rate. |
Sound | To EN14825, 53.0 dB(A) (outdoor); 44.0 dB(A) (indoor). Manufacturer guidanceSound power level. |
Air flow | 3542 m³/h. Manufacturer guidanceAir to water unit rated airflow (outdoor). |
Integral accessories | Integrated back up heater, 6 kW (2 step). |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Europe |
Daikin Altherma High Capacity H HT Heat Pump EPRA-DW1/V3 (Sizes 14-16-18) - Heating system
Daikin Altherma High Capacity R32 Monobloc EB/DLA-D3V3/W1 (Sizes 9-11-14-16) - Heating system
Daikin Altherma Low Capacity R32 Monobloc EB/DLA-EV3 (Sizes 4-6-8) - Heat pump
Low Temperature High Capacity R-Split Heat Pump (Size 11-14-16) - Water heater
Low Temperature Low Capacity R-Split Heat Pump (Size 4-6-8) - Heating system