NBS Source
I'm a manufacturer
Compare variants

Discreet Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ CPS/SSF - Rainscreen Flat Panel Cladding System

Verified by manufacturer 4 months ago

Aluminium Discreet-Fix Flat Panel - Vertical

Architectural Profiles Ltd Variant:
Third party certifications:
  • CWCT Certificate

    CWCT Certificate

    Certificate type

Slimwall™ CPS-SSF Discreet-Fix Flat Panel Vertical Wall cladding system

Jump to:
+44 (0)118 927 2424 Website

Application

Wall cladding plank profiles. Applications include: Educational and leisure facilities, commercial premises, offices and manufacturing facilities.

Description

Slimwall™ CPS-SSF Discreet-Fix Flat Panel Wall cladding system.


Features and benefits:

  • 35 mm deep Discreet-Fix flat panel with modules available of 500–1100 mm, joint size of 20–30 mm and lengths up to 6 m.
  • All system components as non-combustible.
  • Matching soffit system available (specified separately).
  • Available in aluminium, Cor-Ten and A1-rated ACM in a range of finishes:
  • Aluminium: PPC, Armacoil™ HDP, Armacoil™ HDP-HT, Anodised, Stucco-Embossed Mill-Finish (SEMF) and Smooth Mill Finish (MF).
  • Cor-Ten: Unweathered.
  • A1-rated ACM: Refer to ACM manufacturer.
  • Available as a fire-resistance rated insulated system assembly when combined with APL Tritherm™ Spacer System, with simple system upgrades for improved fire resistance performance.
  • Successfully tested to CWCT-standards.
  • A1 fire-rated coatings available.
  • Available with coating warranties up to 40 years including in marine environments.
  • Available as Airwall™ - perforated.
  • System constructions available onto APL StrongBak™, cladding rails, SFS and blockwork.


System components:

  • Liner sheet (if onto cladding rails).
  • APL StrongBak™ (specified separately).
  • Subframe (dependent on substrate).
  • Profile and flashings.

General information

Color

Other

Guidance for specification option:

Standard RAL Range; Contact APL for full details; Bespoke upon request

Silver

Guidance for specification option:

Aluminium

Manufacturer guidance

Aluminium: Standard RAL Range; Contact APL for full details; Bespoke upon request

Cor-Ten: Unweathered.

Finish

Natural

Guidance for specification option:

Smooth mill-finish aluminium

Unweathered Cor-Ten

Powder-coated

Guidance for specification option:

Class 1 or Class 2

Full RAL colour range and / or contact

APL for additional finishes such as anodised-look

Embossed

Guidance for specification option:

Stucco-embossed Armacoil™ HDP (Subject to minimum quantity)

Painted

Guidance for specification option:

Aluminium with Armacoil™ HDP or Armacoil™HDP-HT (Subject to minimum quantity)

Anodized

Guidance for specification option:

Refer to APL for details

Manufacturer guidance

PPC, Armacoil™ HDP, Armacoil™HDP-HT, Smooth Mill Finish (MF), Natural, Anodised

Material

Cor-Ten

Aluminium

Shape

Other

Guidance for specification option:

Flat rainscreen panel

Rectangle

Length

Bespoke

Guidance for specification option:

Maximum length 6 m.

Width

Bespoke

Manufacturer guidance

Module 200–1100 mm with joint size 5–20 mm.

Height

35 mm

Guidance for specification option:

35mm as standard

Bespoke available upon request

Warranty description

25 year

Uniclass

Ss_25_20_68_50 Metal profiled sheet self-supporting cladding systemsPrimary

CAWS

H31/120 Metal

H92/120 Rainscreen cladding

H31/10 Metal

Specification data - Metal profiled sheet self-supporting cladding systems

Liner sheets

-

Material

AP19 LPH Liner sheet.

Guidance for specification option:

Cladding rails.

APL StrongBak™.

Guidance for specification option:

Long-span structural framing system (specified separately).

Other.

Guidance for specification option:

 SFS/ blockwork substrate/ timber - refer to relevant manufacturer.


Minimum FR-rated breather membrane required to outside face of P600 (APZ) where a fully-filled system is utilized.

Primary fasteners

APL P191/HH fixing range.

End and side laps

End lap minimum 75 mm; APL P191/HH fixing range at one per mid span; APL P103 + P108/VCT sidelap sealant range; P152 Flute Fillers.

Guidance for specification option:

Where using 19LPH liner.

Air and vapour control layer

-

Material

AP19 LPH Liner sheet.

Guidance for specification option:

Cladding rails.

APL StrongBak™.

Guidance for specification option:

Specified separately.

Other.

Guidance for specification option:

SFS/ blockwork substrate/ timber - refer to relevant manufacturer.

Manufacturer guidance

Minimum FR-rated breather membrane required to outside face of P600 (APZ) where a fully-filled system is utilized.

Fasteners

APL P191/HH range.

Sealing

AP19 LPH Liner sheet (sidelaps sealed with two runs of P108/VCT).

Guidance for specification option:

Cladding rails -

Other.

Guidance for specification option:

 SFS/Blockwork substrate/Timber - refer to relevant manufacturer.


Minimum FR-rated breather membrane required to outside face of P600 (APZ) where a fully-filled system is utilized.

Spacers

Tritherm Spacer System® - fully-filled cavity (CWCT-tested) and ventilated cavity.

Guidance for specification option:

  • Cladding Rails: P665 RWB, P546 Isopad, P157 HH Bracket, P600 + P601 Horizontal Zed.
  • SFS/ blockwork/Timber - P618 Tophat, P665 RWB, P546 Isopad, P157 HH Bracket, P600 + P601 Horizontal Zed.

Tritherm Spacer System® - ventilated cavity, SFS/ blockwork/ timber substrate.

Guidance for specification option:

P618 Tophat, P665-ALU RWB, P546 Isopad, P157-ALU HH Bracket, P754 + P785 Horizontal ALU Zed.


Tritherm Spacer System® - ventilated cavity.

Guidance for specification option:

SFS/ Blockwork / Timber substrate - P521/4 + P528/4 HH brackets with P546 Isopad thermal breaks, P759 vertical ALU "L" rail, P754 horizontal ALU zed.

Acoustic insulation

A1-rated with thickness and performance specification as required to meet performance.

Guidance for specification option:

Insert requirements.

Thermal insulation

A1-rated.

Guidance for specification option:

A1-rated, thickness as required to meet U-value requirement with min lambda of 0.040 for all calculation purposes; where fully-filled cavity, allow an extra 10% of cavity thickness for soft-type insulation to fill rear of panel:

  • Cladding rails: With maximum 33 kg/m³ type, use P211/ Insulation Pins with P534 Washer at three per m², bonded to liner sheet with P663 Adhesive.
  • SFS/ blockwork/ timber - With maximum 33 kg/m³ type, use P211/Insulation Pins with P534 at three per m² fixed to P618 Tophat.
  • Where Rainscreen-Type (eg Duoslab) is used, use P211/DS/SS/70 in centres and P211/DS/PL/7/25 at each board perimeter, fixed back with P191/HH fixing.


Refer to the relevant U-value table in the supporting literature.

Breather membrane

-

Material

Minimum fire-rated B-s2,d0.

Joint sealant

As per membrane manufacturer's recommendations.

Cavity fire barriers

-

Horizontal barriers

As per cavity barrier manufacturer requirements.

Vertical barriers

As per cavity barrier manufacturer requirements.

External sheets

-

Material

Aluminium - solid.

Aluminium - Airwall™ (perforated).

Primary fasteners

APL 191/LP fixing for secret fix.

Secondary fixings

N/A - "male" and "female" type joint.

End and side laps

N/A - "male" and "female" type joint; GEX/F2 flashing at corners.

Wall glazing

Required.

Not required.

System accessories

APL System Flashings including GE/F1 and GEX/F2 at system joints.

APL Sealants as APL recommendations and to match profiles.

APL Fixings (P191 & P192).

P087 vertical drainage cover trim fixed to vertical APZ.

Fixings

APL P191/LP range.

Colour/ Finish:

Armacoil™ HDP.

Guidance for specification option:

Subject to minimum quantities. Insert colour required.

Armacoil™ HDP-HT.

Guidance for specification option:

Insert colour required.

Anodized.

Guidance for specification option:

Contact APL for details.

Polyester powder-coated, class 1.

Guidance for specification option:

Insert colour/ finish required.

Polyester powder-coated, class 2.

Guidance for specification option:

Insert colour/ finish required.

Show more

Manufacturer guidance

Insert colour requirements.

NominalThickness

1.5–3.0 mm.

Minimum bearing area

50 mm.

Liner Supports

-

Manufacturer guidance

Subject to loadings.

Centres are to general areas only, closer at high load zones.


  • Cladding Rails - Maximum 1800 mm centres in general areas, closer at high load zones/ corners.
  • SFS - Refer to SFS manufacturer.
  • StrongBak - refer to separate specification.


Profile supports

-

Manufacturer guidance

Subject to loadings. Centres are to general areas only, closer at high load zones.

 

  • Onto Cladding Rails: 1) P665/P157 brackets at max 1000 mm centres horizontally and to allow for horizontal P600 to be each side of each panel horizontal joint and at cladding rail centres vertically; 2) Horizontal P600s fixed to every bracket.
  • Onto SFS with full-filled cavity: 1) Horizontal P618 top hats at max 1200 mm vertical centres and to allow for horizontal P600 to be each side of each panel horizontal joint; 2) P665/P157 brackets at max 1000 mm centres horizontally, each side of each panel horizontal joint and every top hat vertically; 3) Horizontal P600s fixed to every bracket.
  • Onto SFS with ventilated cavity: Contact APL.
  • Onto StrongBak: Refer to separate specification/ contact APL.


Orientation

Vertical.

Recycled content (minimum)

90%, up to 95%.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

High

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

%

Guidance for specification option:

Subject to substrate (steel or aluminium) and grade of aluminium

Third party certifications

CWCT Certificate

CWCT Certificate

CWCT - Snaploc & Slimwall

Literature

APL Tritherm Spacer System℗ - Aluminium - Data Sheet

APL Tritherm Spacer System℗ - Aluminium - Data Sheet

APL Tritherm Steel Spacer System - Cladding - System Summary

APL Tritherm Steel Spacer System - Cladding - System Summary

APL Tritherm Spacer System℗ - STEEL - Data Sheet

APL Tritherm Spacer System℗ - STEEL - Data Sheet

U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails

U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails

U-Values + Build Up - WALLS - Horizontal Orientation to  SFS / Blockwork

U-Values + Build Up - WALLS - Horizontal Orientation to SFS / Blockwork

U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails

U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails

U-Values + Build Up - WALLS - Vertical Orientation to  SFS / Blockwork

U-Values + Build Up - WALLS - Vertical Orientation to SFS / Blockwork

APL Armacoil™HDP + HDP-HT - Product Brochure

APL Armacoil™HDP + HDP-HT - Product Brochure

APL Armacoil™HDP-HT - Product Brochure

APL Armacoil™HDP-HT - Product Brochure

APL StrongBak™ - Cladding - System Brochure

APL StrongBak™ - Cladding - System Brochure

APL Cladding Systems Brochure

APL Cladding Systems Brochure

APL Slimwall™ - Cladding - System Brochure

APL Slimwall™ - Cladding - System Brochure

APL Slimwall™ - System Summary

APL Slimwall™ - System Summary

APL StrongBak™ - System Summary

APL StrongBak™ - System Summary

APL AluE™ Tritherm™ Aluminium  Spacer System - Cladding - System Summary

APL AluE™ Tritherm™ Aluminium Spacer System - Cladding - System Summary

Case studies

APL Case Study - StrongBak™ - Derry Sports Complex

APL Case Study - StrongBak™ - Derry Sports Complex

APL Case Study - Aluminium APL Snaploc™ & Slimwall™ - Hellaby Business Centre

APL Case Study - Aluminium APL Snaploc™ & Slimwall™ - Hellaby Business Centre

APL Case Study - Aluminium Sinusoidal Roofing & Perforated Cladding - Birmingham Energy Innovation Centre

APL Case Study - Aluminium Sinusoidal Roofing & Perforated Cladding - Birmingham Energy Innovation Centre

APL Case Study - AP65ZS Zipseam™ Roofing & Sinusoidal, Slimwall™ & Louvre Cladding - CMR Medical

APL Case Study - AP65ZS Zipseam™ Roofing & Sinusoidal, Slimwall™ & Louvre Cladding - CMR Medical

APL Case Study - APL Slimwall™ - The Hamptons, Gillingham

APL Case Study - APL Slimwall™ - The Hamptons, Gillingham

APL Case Study - APL StrongBak™ & Sinusoidal Cladding - GTIMC, University of Sheffield

APL Case Study - APL StrongBak™ & Sinusoidal Cladding - GTIMC, University of Sheffield

APL Case Study - StrongBak™ & Slimall™ - Magenta Storage

APL Case Study - StrongBak™ & Slimall™ - Magenta Storage

Similar products from Architectural Profiles Ltd

Concave / Half-Round Profile Wall System - AP50-Curveline™  - Concave Profile Cladding System

Concave / Half-Round Profile Wall System - AP50-Curveline™ - Concave Profile Cladding System

Corrugated / Sinusoidal (19mm Deep) Profile Wall System - AP18HR  - Sinusoidal Profile Cladding System

Corrugated / Sinusoidal (19mm Deep) Profile Wall System - AP18HR - Sinusoidal Profile Cladding System

Custom Bespoke Profile Wall Systems - AP-CBP Range - Custom Profile Cladding System

Custom Bespoke Profile Wall Systems - AP-CBP Range - Custom Profile Cladding System

Face-Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ (FF) - Flat Panel Rainscreen Cladding System

Face-Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ (FF) - Flat Panel Rainscreen Cladding System

Half-Round Profile Wall System - AP50HR - Half-round Profile Cladding System

Half-Round Profile Wall System - AP50HR - Half-round Profile Cladding System

Long-span Structural Wall Panel System - APL StrongBak™  - Non-Combustible

Long-span Structural Wall Panel System - APL StrongBak™ - Non-Combustible

Louvre Profile Wall Cladding System - AP70 LCP  - Louvre Profile Cladding System

Louvre Profile Wall Cladding System - AP70 LCP - Louvre Profile Cladding System

Louvre System - Live Louvres - APL LB3 & LB4 - Live Louvre System

Louvre System - Live Louvres - APL LB3 & LB4 - Live Louvre System

Secret-Fix Flat Plank & Panel Rainscreen Cladding System - APL Slimwall™ SFP - Secret-Fix Rainscreen Panel

Secret-Fix Flat Plank & Panel Rainscreen Cladding System - APL Slimwall™ SFP - Secret-Fix Rainscreen Panel

Sinusoidal / Half-Round (40mm Deep) Profile Wall System - AP45HR - Sinusoidal Profile Cladding System

Sinusoidal / Half-Round (40mm Deep) Profile Wall System - AP45HR - Sinusoidal Profile Cladding System