Vapour control layer.
For internal walls, ceilings and floors.
Daltex® 146 VCL is a high resistance vapour barrier for internal walls, ceilings and floors, specifically designed to reduce the transfer of water vapour through the structure when placed on the warm side of the insulation.
Features and benefits:
Rolls should be stored flat on a clean, level surface and kept under cover.
Method of installation:
The vapour control layer should be installed as detailed in National Building Regulations. Any guidelines concerning installation that are supplied with the product should be consulted prior to laying. For general information – the vapour control layer should be positioned on the warm side of the thermal insulation.
In ceilings the product is placed between the underside of the rafters and the ceiling lining. In floors the product is placed on top of the structural decking or insulation (where present) and below any screed or sensitive floor coverings. Adjacent sheets should be lapped by 150 mm and sealed with a suitable tape. Minimise penetrations caused by services and seal all joints.
Color | Black |
Material | Polyethene |
Shape | Rectangle |
Length | 50000 mm |
Width | 1500 mm |
Warranty description | Other |
Uniclass | |
CAWS | H30/261 Air and vapour control membrane H30/30 Air and vapour control membrane H31/261 Air and vapour control membrane H31/45 Air and vapour control membrane J21/395 Air and vapour control layer J31/330 Air and vapour control layer J41/395 Air and vapour control layer J42/395 Air and vapour control layer P10/310 Air and vapour control layer P10/60 Air and vapour control layer |
Material | Polyethene |
Purpose | Vapour control layer. |
Standard | To EN 13984. |
Performance characteristics | |
Tensile strength (minimum) | To EN 12311-1, 270 N/50 mm (MD); 180 N/50 mm (CD). |
Tear resistance | To EN 12310-1, 190 N (MD); 170 N (CD). |
Elongation to break | To EN 12311-1, 70% (MD/CD). |
Water vapour resistance (minimum) | To EN 1931, 15 m (Sd) (+/- 2). |
Fire performance | To EN 11925-2, Class F. |
Third-party certification | UKCA approved. |
Physical properties | |
Weight (minimum) | 146 g/m². |
Class (minimum) | W1. Guidance for specification option: To EN 1928. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Manufacturing plant location |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |