Verified by manufacturer 1 day ago
Health & Safety Accreditation
Certificate type
CHAS
Certificate type
Constructionline
Certificate type
ISO 9001 Quality Management
Certificate type
Fire-rated door protection panels and plates.
Suitable for fitting to FD30 and FD60 doors as well as non fire-rated doors
Door protection panels and plates offering protection from holes, splinters and dents which are caused by impact from everyday use. This damage can impede the function of a fire door.
Panels can be cut to any shape or size.
Fully fire-certified, the protective panels can be either retrofitted to existing doors or installed on new doors without affecting the integrity of a fire rated door.
Approvals:
Fire Test Information
Textured Extruded Sheet:
Smooth Extruded Sheet:
VOC Emissions
Yeoman Shield PVC-U Falmouth Wall & Door Protection panels have been tested for VOC to ISO 16000-10:2006 Indoor air - Part 10.
The test showed the following results:
The interpretation of these results by BRE are if all the walls (less door and window) of the 30 m³ reference room described in BS EN 16515‑2017 (with a ventilation rate of 0.5 air changes per hour) were clad with the Yeoman Shield PVC-U Falmouth Wall & Door Protection Panels, the increase in TVOC in the room would
be <20 µg/m³ for TVOC and <10 µg/m³ for formaldehyde and these are deemed to be low.
BREEAM Hea 02 has limits of 300 µg/m³ for TVOC and 100 µg/m³ for formaldehyde, so the theoretical increases in TVOC and formaldehyde from using the PVC-U sheet are deemed as low.
Color | Black Guidance for specification option: BS 00 E 53 -stock colour Blue Guidance for specification option:
Brown Guidance for specification option: BS 08 B 29 - Stock colour Cream Guidance for specification option: BS 10 B 15 - Stock colour Green Guidance for specification option:
Manufacturer guidanceconsult colour card in associated content. |
Finish | Other Manufacturer guidanceYeoman Shield Falmouth |
Material | PVC-U |
Shape | Rectangle |
Length | 2500 mm |
Width | 1250 mm |
Height | 2 mm Manufacturer guidance2 mm flat panels |
Uniclass | |
CAWS | L20/430 Wood doorsets L20/410 Wood doorsets L20/55 Doorsets L20/20 Wood flush doors L20/230 Wood flush doors P21/46 Kick plates P20/170 Proprietary P21/44 Push plates P21/670 Push plates P20/30 Proprietary P21/690 Kick plates |
Material | |
Thermoplastics | Vinylac, a specially formulated un-plasticized polyvinyl chloride (PVC-U). |
Dimensions | |
Length | 2500 mm.Guidance for specification option: Standard panel size (cut to requirements). |
Width | 1250 mm.Guidance for specification option: Standard panel size (cut to requirements). |
Sheet thickness | 2 mm. |
Colour | Guidance for specification option: Consult manufacturer's literature for options and related details e.g. light reflectance value (LRV) and insert requirements.
|
Fire performance | BS 476: Part 7: 1997 - Class 1Y and BS 476: Part 6: 1989 + A1: 2009 - Class 0. |
Function | Protection panel. Kick plate. Push plate. Other. Manufacturer guidanceInsert size(s) required as appropriate. |
Sheet size | Panels can be cut and shaped in many ways to meet individual requirements and offer greater design capabilities. Contact manufacturer for information. |
Accessories | Not required. Tape. Silicon. |
Material | PVC-U |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
IFC2X3 | 2 | |
Revit 2015 | 2 |