Verified by manufacturer 25 days ago
A2-fire rated breather membrane.
DuPont™ Tyvek® Trifecta™ installation (CAWS): See linked clauses for details.
Storage
Rolls of Tyvek® Trifecta™ should be stored palletised or on their sides on a smooth clean surface, under cover and protected from direct sunlight.
General
Care should be taken when handling the membrane in order to prevent tears and punctures occurring. Any that do occur should be repaired with DuPont™ AirGuard® FR System Tape (1310FR).
Application
Unroll Tyvek® Trifecta™ horizontally over the face of the construction. Ensure maximum coverage of membrane by extending 100 mm minimum below the lowest structural timber/steel member.
Fixing – to timber studs/sheathing
Fix Tyvek® Trifecta™ with stainless steel staples or corrosion resistant nails; a rubber or EPDM washer should sit between the screw heads and the membrane to avoid water ingress. Alternatively, fixings can be applied in the overlap section. Fix membrane at 600 mm centres horizontally, 300 mm centres vertically and at 150 mm centres at joints and openings.
Fixing - to masonry
Tyvek® Trifecta™ may be fixed to masonry with a suitable anchor fixing system or a masonry nail/screw and EPDM rubber washer. Fixings should be at maximum 500 mm centres.
Fixing - to steelwork (SFS)
Tyvek® Trifecta™ can be fixed to Steelwork with an appropriate mechanical fixing through to the steel structure, commonly suitable drill-tip or self-tapping screws may be used. The screws must sit flush (not countersunk) and a rubber or EPDM washer should sit between the screw heads and the membrane to avoid water ingress. Screw fixings should be spaced vertically at 500 mm centres on every stud (typically spaced at 600 mm horizontal centres).
Fixing - Rainscreen Cladding Applications
Tyvek® Trifecta™ may be fixed to the external face of a cement bonded particle board, external Gypsum board or other Euroclass A1/A2 rated sheathing, using a sheathing appropriate fixing. Appropriate fixings range from stainless Steel Staples for denser boards to drill-tip or self- tapping screws (with soft washers). See Fixing - to steelwork (SFS) above. Tyvek® double sided tape (1310D) can be used to seal laps at perimeters.
Initial fixings are preferable in the lap line or covered with AirGuard® FR System Tape (1310FR) to protect the membranes integrity.
In many cases, the retrospective fixing of cladding brackets (and insulation) will provide the principle security for the membrane. Care should be taken to ensure these components are fixed tightly over the membrane to avoid water ingress.
Laps
All horizontal laps should be 100 mm. Vertical laps should be 150 mm min.
Non-combustible vapour permeable membrane with a A2-s1,d0 (EN 13501-1) fire performance and Class W1 water resistance, allowing improved protection and fire safety over standard membranes.
This product is suitable for use in high risk buildings, including those above the fire safety threshold: 18 m England Wales, 11 m Scotland. The complete A-rated fire membrane system includes the AirGuard® FR System Tape for lap sealing.
Features and benefits:
Color | Black |
Finish | Smooth |
Material | Composite |
Shape | Rectangle Guidance for specification option: Supplied in rolls. Other |
Length | 25000 mm |
Width | 1500 mm |
Height | 0.4 mm |
Warranty description | 25 year |
Uniclass | |
CAWS | H20/10 Sheet cladding H20/155 Sheet cladding (attached to timber battens) H30/50 Breather membrane H31/55 Breather membrane H31/280 Breather membrane H30/350 Breather membrane H21/20 Breather membrane H21/130 Breather membrane H92/785 Breather membrane P10/320 Breather membrane P10/65 Breather membrane |
Standard | To BS EN 13859-2: 2010. |
Performance characteristics | Water vapour transmission (sd) to EN ISO 12572: 0.08 m. |
Class (minimum) | W1.Guidance for specification option: To EN 1928. |
Material | Two-layer laminate: glass scrim with flame-retardant special film. |
Form | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. Supplied in rolls. |
Third-party certification | BBA pending.Guidance for specification option: Consult manufacturer for details. |
Weight (minimum) | 400 g/m².Guidance for specification option: Nominal. Minimum: 365 g/m²; maximum: 435 g/m². |
Thickness (minimum) | Manufacturer's standard. |
Fixings | Guidance for specification option: Mechanical fixings such as staples, screws with washers, etc. Consult manufacturer's literature details of appropriate fixings, tapes etc. based on substrate and/or application, and insert requirements. |
Roll size | 1.5 x 25 m. Guidance for specification option: Width x length. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Europe |
Material | Composite |
Recyclability | 0 |