NBS Source
I'm a manufacturer

eClips® VL Rainscreen Façade Support System - Rainscreen Cladding

Verified by manufacturer 4 days ago

Maple Façades Third party certifications:
  • CWCT Certificate

    CWCT Certificate

    Certificate type

  • BR 135

    BR 135

    Certificate type

Rainscreen façade support system typically suited for concrete stair cores/flat surface areas and portrait panels.

Jump to:
+44 (0)161 456 6644 Website

Application

eClips VL can be used for concrete stair cores and flat surface areas. It particularly lends itself to portrait panels.

Description

The eClips rainscreen support system provides the perfect foundation for rainscreen façades, and makes buildings more thermally efficient. By increasing the distance between brackets and combining patented insulation-fix technology with removable helping-hand clips, we reduce the number of penetrations in the structure, ensure the tightness of insulation sheets and keep air leakage to a minimum.


System flexibility

The eClips rainscreen support system allows a range of products to be fixed to the building envelope, and opens up endless creative possibilities for architects and contractors.


Thermally efficient stainless-steel brackets

Positioning fewer, higher thermal specification and better load-bearing brackets at significantly larger centres reduces overall costs and cuts installation time, as well as reducing the thermal conductivity of the sub-frame.


Sustainable helping-hand clip

The design of the brackets allows the smallest possible footprint when installing the insulation thanks to the sustainable helping-hand clip, allowing fitters to ensure there are no air pockets (critical for thermal efficiency and fire protection).


Patented insulation-fix technology

eClips insulation clips improve U-values and weather-sealing performance by reducing the number of penetrations into the fixing grounds – vertical insulation clips connect to the T/L rail mullion to securely hold the insulation.

General information

Color

Beige

Black

Blue

Bronze

Brown

Show more

Finish

PVdF

Anodized

Powder-coated

Mill

Material

Aluminium

Cor-Ten

Stainless steel

Shape

Rectangle

Square

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H20/150 Sheet cladding (attached to metal support systems)

H20/10 Sheet cladding

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Rainscreen cladding system design

Thermal insulation

To suit project specific requirements for U-value.

Guidance for specification option:

A1/A2-rated mineral wool insulation - thickness dependent on U-value requirements.

Secondary support structure

eClips VL Rainscreen Façade Support System.

Guidance for specification option:

Consult manufacturer for details.

Cavity fire barriers

-

Horizontal

Guidance for specification option:

Consult fire engineer and insert requirements.

Vertical

Guidance for specification option:

Consult fire engineer and insert requirements.

Cladding panels

-

Material

Guidance for specification option:

Panel material to be contractor's choice; insert details.

Manufacturer guidance

eClips provides support system only. not including panel; can incorporate wide-range of materials and types.

Panel joints

Guidance for specification option:

Panel material to be contractor's choice; insert details.

Reveals

To suit system requirements around window openings.

Guidance for specification option:

Consult manufacturer and insert requirements.

System accessories

Removable and recyclable helping-hand clip.

Guidance for specification option:

Can be reused or recycled after the support structure is fixed permanently.

Design of the brackets allows the smallest possible footprint when installing the insulation.

Other.

Guidance for specification option:

Insert requirements.

Fixing system

Discreet hidden fixing.

Bracket

304 grade stainless steel.

Guidance for specification option:

  • Laser cut and folded to suit project location.
  • CWCT tested to 12 kN/m².
  • Removable and recyclable helping-hand clip.

Bracket centres (maximum)

Up to 1200 mm.

Projection

Guidance for specification option:

Insert requirements. Ranging from 90 to 290 mm.

Mullion

6063 grade T6 aluminium.

Guidance for specification option:

  • T/L profiled mullions maximum centres up to 1200 mm.
  • Serrations allow for vertical adjustment on site.
  • Supplied in lengths of 6000 mm as standard.

Insulation clips

6063 grade T6 aluminium polyester powder-coated (Maple orange).

Guidance for specification option:

  • Maple orange colour for visibility.
  • Patent-pending design improves HSE and installation efficiency when fixing insulation into position.
  • Adaptable for different insulation thicknesses.
  • Manual fixing for faster installation, less fixing into SFS studs.
  • Maximum centres of up to 600 mm.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

United Kingdom

Recyclability

Bespoke product minimal reuse potential. 95% + recyclability

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

95 %

Third party certifications

CWCT Certificate

CWCT Certificate

CWCT Testing Certificate

BR 135

BR 135

Fire Test Certificate

Literature

eClips Rainscreen Support System Brochure

eClips Rainscreen Support System Brochure