Verified by manufacturer 6 months ago
EDA 250A Door Operators
Full energy swing door operators.
Independently tested under the Certifre scheme as suitable for 60 minute fire rated doors for both push and pull applications.
See Cerificate of approval for more details.
These units offers a range of operating modes that enable the door to be opened under power when required and used as a conventional manual swing door at all other times. The ED 100A/ ED 250A opens the door at precise controlled speeds and forces assuring safety for all users. The door can be opened manually or automatically via radar detector, push pad or access control. As ED 100A/ ED 250A operate under full energy additional safety equipment must be fitted. The combination of low operating noise levels and the compact Contur design ensures the ED 100A/ ED 250A will integrate into the most sensitive of environments. Both operators may be installed as push-version with standard arm and as pull-version with slide channel.
Features and benefits:
Product options:
-ED 100A
-ED 250A:
Color | Silver Other |
Finish | Anodized Guidance for specification option: Silver aluminium. Powder-coated |
Material | Aluminium |
Shape | Rectangle |
Length | 685 mm |
Width | 70 mm |
Height | 130 mm |
Warranty description | One year |
Uniclass | |
CAWS | P21/12 Controlled door closers P21/410 Controlled door closers |
Product range |
Form | Overhead. |
Materials and finishes | |
Bodies | Cast aluminium. |
Arms | Cast aluminium. |
Casings | Anodized aluminium. |
Colour | Polyester powder coated, RAL.Guidance for specification option: Insert requirements. Silver anodized aluminium. |
Type | Single operator. Double operator. Manufacturer guidanceApplication. |
Accessories | Eagle 1 motion detector, black. Eagle 1 motion detector, silver. Eagle 1 motion detector, white. Hingsafe back edge protection, brown. Guidance for specification option: PVC-U. Hingsafe back edge protection, white. Guidance for specification option: PVC-U. |
Cover | Single cover at 685 mm to span a single operator. Two single covers 1400 mm (minimum) with VARIO infill tow span both operators. Professional continuous cover 1400 mm (minimim) to span over both operators. |
Arms | Push side. Guidance for specification option: Operator to be installed onto the Push side of the door using standard scissor arm with a max revel depth of 300 mm (ED100) or 500 mm (ED250). Pull side. Guidance for specification option: Operator to be installed onto the Pull Side of the door with slide channel with a max revel depth of +/- 30 mm. |
Closing | To EN 1154, EN 4–7, adjustable. Manufacturer guidanceClosing force. |
Program switch | Not required. Mechanical. Mechanical and lockable. Fully electronic. |
Dimensions | 685 x 70 x 130 mm. |
ESR door co-ordinator | Not required (single doors). Required (double rebated doors). |
Extension | 30/ 60/ 90 mm. Manufacturer guidanceAxle extension. |
Operation | Manual open, motor assisted close. Guidance for specification option: Door can be opened manually; the opening safety sensors are operational. Door will close with motor assistance, max force 150 N. Radar detection. Guidance for specification option: Door can be opened under power by radar detection, using a push pad or access control on either side of the door. The safety sensors will be active. Power (fail safe). Guidance for specification option: The operator can fully open under power (fail safe) on receipt of fire alarm signal. |
Spring strength | 54 N (EN 6). Manufacturer guidanceMaximum closing spring force. |
Sensors | MotionIQ. Eagle Artek. Manufacturer guidanceRadar motion sensors. |
Safety devices | 2D Flatscan SW time of flight safety sensor fitted to opening and closing side of each door leaf to monitor leading edge with roller blind for hinge protection. 2D Flatscan SW time of flight safety sensor fitted to opening door leaf and 3D Flatscan time of flight activation and safety sensor fitted to the closing side monitoring the hinge (no roller blind required). 3D Flatscan SW time of flight activation and safety sensor fitted to opening and closing side of each door leaf to monitor leading edge and hinge areas. Framed glazed safety barrier with toughened glass infills installed along the line of doors in the open position. Self-regulating safety system monitoring all door movements including closing force as standard. |
Power supply | Not required. Integrated power supply. Guidance for specification option:
Manufacturer guidanceIntegrated emergency power supply. |
Locking facility | Not required. dormakaba SVP Lock. Surface applied electromagnetic. Manual keyed cylinder and lock (operator must by powered off before lock engaged). |
Power consumption | 240 W. |
Speed | Opening and closing: 27° per second (maximum). |
Door leaf | 700–1600 mm. Guidance for specification option: Single-leaf version, hinged. Single-leaf version, pivoted (based on 70 mm pivot centres). 1450–3200 mm. Guidance for specification option: Double-leaf version, hinged. 1590–3200 mm. Guidance for specification option: Double-leaf version, pivoted (based on 70 mm pivot centres). |
Depth | ±30 mm. Guidance for specification option: Lintel depth for slide channel. (Lintel depth for standard arm: 0–500 mm). |
Weight | For doors with weight of up to 250 kg. |
Width | For doors with width of up to 1600 mm. |
Contains Red List materials | Yes Guidance for specification option: Lead(Pb): 7439-92-1 (CAS-No) is used in the steel alloy. The concentration of lead in the alloy does not exceed 0.35% (by mass). |
Country of material origin | Germany |
Country of product manufacture | Germany |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidance
|
Recyclability | Manufacturer guidance
|
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidance
|
Platform | Compatible | Version |
---|---|---|
- | 1 |