NBS Source
I'm a manufacturer
Compare variants

Edge EVO 2.0 - Reversible Air/ Water Heat Pump

Verified by manufacturer 3 months ago

2.1

Clivet UK Variant:

A single-unit reversible air/ water heat pump for heating, cooling and the production of domestic hot water.

Jump to:
02392381235 Website

Application

Designed for outdoor applications.

Description

Edge EVO 2.0 - EXC is a monobloc reversible air/water heat pump for heating, cooling and domestic hot water production. The unit was designed and made to be installed outdoors, with the need to only connect the power supply and water pipes.


Seasonal efficiency class in heating mode (according to EU 811/2013):

  • A++ or A+ (water supply at 55 °C).
  • A++ or A++ (water supply at 35 °C).


Features and benefits:

  • Minimum footprint: all units from 4 to 16 kW are single fan with compact dimensions
  • Improved performance guarantees class A++ and A++ in heating in low temperature (35°C water supply) and class A++ and A+ in medium temperature (55°C water supply).
  • Effective in cooling with SEER values of up to 5.98.
  • Two silent and super-silent operating modes for even more challenging demands.
  • Extended operating limits: reliable operation in heating mode down to -25°C outside air also allows water to be produced at 60°C in flow down to -15°C outside air.
  • Available in a hybrid version, for single or cascade combination with Clivet boilers up to 200 kW, suitable for centralized systems. In the hybrid version it is possible to have a flow temperature up to 75 °C.
  • Connectivity APP: equipped with WiFi.
  • ELFOControl3 EVO: compatible with ELFOControl3 EVO, Clivet's advanced control system to manage the operation of the entire system, guaranteeing simplicity of use, high performance thanks to the optimization of unit operation, improved comfort and security of operation continuity for all environmental conditions.
  • Smart-grid and photovoltaics.

General information

Color

Cream

Guidance for specification option:

RAL 9001.

White

Finish

Galvanized

Powder-coated

Material

Steel

Aluminium

Copper

Shape

Rectangle

Warranty description

Seven year

Uniclass

Pr_70_60_37_04 Air-to-water heat pumpsPrimary

CAWS

T90/505 Air-to-water heat pumps

T90/505 Air-to-water heat pumps

Specification data - Air-to-water heat pumps

Standards

-

Safety and environmental

To BS EN 378-1 and BS EN 378-2.

Test requirements

To BS EN 14511-1, BS EN 14511-2, BS EN 14511-3 and BS EN 14511-4.

Electrical safety

To BS EN 60335-2-40.

Heat pump type

Monobloc.

Mode

Cooling.

Heating.

Coefficient of performance (minimum)

5.10.

Manufacturer guidance

Inlet/outlet water temperature 30/35°C, outdoor air temperature 7°C dry bulb/ 6°C wet bulb.

Output

-

Heating

4.20 kW.

Manufacturer guidance

Inlet/outlet water temperature 30/35°C, outdoor air temperature 7°C dry bulb / 6°C wet bulb.

Cooling

4.50 kW.

Manufacturer guidance

Inlet/outlet water temperature 23/18°C, outdoor air temperature 35°C dry bulb / 27°C wet bulb.

Fan

-

Type

Axial.

Fan drive

Direct.

Configuration

Horizontal.

Electrical supply type

Three phase.

Compressor

-

Type

Rotary vane.

Guidance for specification option:

Twin.

Sealing

Hermetically sealed.

Drive

Inverter driven.

Accessories

Not required.

GAS BOILER_UC / GAS BOILER_FE 24.4-33.4 - four-pipe condensing boiler for hybrid heat pumps.

Guidance for specification option:

Hybrid configuration.

KCSAFX - ø60/100 mm vertical coaxial fitting.

Guidance for specification option:

Hybrid configuration.

CCOAX - 90° coaxial elbow for ø60/100 mm horizontal outlet that can be adjusted at 360°.

Guidance for specification option:

Hybrid configuration.

TCOAX - L1000 mm ø60/100 coaxial pipe with terminal.

Guidance for specification option:

Hybrid configuration.

KAS80X - ø80 mm vertical fittings.

Guidance for specification option:

Hybrid configuration.

KSDFX - ø80 mm flue gas splitter kit.

Guidance for specification option:

Hybrid configuration.

VDACSX - Thermostatic switching valve for domestic water.

Guidance for specification option:

Hybrid configuration.

GAS BOILER_UC 70.2-115.2-200F.2 - two-pipe condensing boiler for hybrid heat pumps.

Guidance for specification option:

Hybrid configuration.

INAILX - INAIL safety kit for installation of single boiler.

Guidance for specification option:

Hybrid configuration.

FH100X - ø100 mm vertical flue gas terminal.

Guidance for specification option:

Hybrid configuration.

HIDUCX - Remote control for UC 70.2-115.2 boilers.

Guidance for specification option:

Hybrid configuration.

IBH - Integrated back-up heater.

Guidance for specification option:

Configuration with electric heater.

IBHX - Back-up electric heater (single-phase).

Guidance for specification option:

Configuration with electric heater.

IBHTX - Back-up electric heater (three-phase).

Guidance for specification option:

Configuration with electric heater.

ACS200X - 200-litre DHW boiler.

Guidance for specification option:

Configuration with DHW boiler.

ACS300X - 300-litre DHW boiler.

Guidance for specification option:

Configuration with DHW boiler.

ACS500X - 500-litre DHW boiler.

Guidance for specification option:

Configuration with DHW boiler.

ACS1000X - 1000-litre DHW boiler.

Guidance for specification option:

Configuration with DHW boiler.

ACS10SX - 1.000-litre DHW boiler with solar coil.

Guidance for specification option:

Configuration with DHW boiler.

SCS08X - Solar coil for ACS200X/ACS300X DHW boilers.

Guidance for specification option:

Configuration with DHW boiler.

SCS12X - Solar coil for ACS ACS500X DHW boilers.

Guidance for specification option:

Configuration with DHW boiler.

QERAX - Connection kit for single-phase heater on DHW storage tank (for ACS200/300/500X).

Guidance for specification option:

Configuration with DHW boiler.

QERATX - Connection kit for three-phase heater on DHW storage tank (for ACS1000X).

Guidance for specification option:

Configuration with DHW boiler.

3DHWX - System/DHW three-way switching valve (SV1).

Guidance for specification option:

Configuration with DHW boiler.

PRSX - DHW recirculation pump.

Guidance for specification option:

Configuration with DHW boiler.

ELFOSun³.

Guidance for specification option:

Configuration with solar thermal panels.

TANKX - System inertial storage tank.

Guidance for specification option:

Configuration with primary and secondary circuit.

KTCAX - Hose kit for connecting the unit to the inertial storage tank.

Guidance for specification option:

Configuration with primary and secondary circuit.

DIX - one-litre hydraulic circuit breaker.

Guidance for specification option:

Configuration with primary and secondary circuit.

DI50-2X - 50-litre hydraulic circuit breaker.

Guidance for specification option:

Configuration with primary and secondary circuit.

DI100X - 100-litre hydraulic circuit breaker.

Guidance for specification option:

Configuration with primary and secondary circuit.

KCSX - Secondary circuit kit (1-litre hydraulic circuit breaker + pump).

Guidance for specification option:

Configuration with primary and secondary circuit.

KIRE2HX - Double zone distribution unit: direct + direct.

Guidance for specification option:

Configuration with primary and secondary circuit.

KIRE2HLX - Double zone distribution unit: direct + mixed (with mixing valve).

Guidance for specification option:

Configuration with primary and secondary circuit.

PCSX - Circulation pump for secondary circuit.

Guidance for specification option:

Configuration with primary and secondary circuit.

PCS2X - Oversized circulation pump for secondary circuit.

Guidance for specification option:

Configuration with primary and secondary circuit.

KTFLX - Hose kit for connection to the unit.

Guidance for specification option:

Supplied separately.

FDMX - Magnetic dirt separator filter for water distribution systems.

Guidance for specification option:

Supplied separately.

VAGX - Safety antifreeze valve for system.

Guidance for specification option:

Supplied separately.

DTX - Drain pan with electric heater.

Guidance for specification option:

Supplied separately.

T1BX - DHW temperature probe and additional heating source at 10 m.

Guidance for specification option:

Supplied separately.

T1B30X - DHW temperature probe and additional heating source at 30 m.

Guidance for specification option:

Supplied separately.

AMRX - Kit of antivibration mounts for floor installation.

Guidance for specification option:

Supplied separately.

AMMSX - Kit of anti-seismic antivibration mounts for floor installation.

Guidance for specification option:

Supplied separately.

ASTFX - Kit of antivibration mounts for installation on wall brackets, inertial storage tank or tray.

Guidance for specification option:

Supplied separately.

KSIPX - Wall fixing bracket kit.

Guidance for specification option:

Supplied separately.

HTC2WX - HID-TConnect two white chronothermostat for temperature control.

Guidance for specification option:

Supplied separately.

SWCX - IoT SwitchConnect receiver / switch.

Guidance for specification option:

Supplied separately.

ELFOControl³ EVO.

Guidance for specification option:

Supplied separately.

Refrigerant

R32.

EnergyEfficiencyRatio

5.50.

Manufacturer guidance

Cooling.

HeatingWaterFlowRate

0.22 m³/h.

Manufacturer guidance

Inlet/outlet water temperature 30/35°C, outdoor air temperature 7°C dry bulb / 6°C wet bulb.

CoolingWaterFlowRate

1.14 m³/h.

Manufacturer guidance

Inlet/outlet water temperature 23/18°C, outdoor air temperature 35°C dry bulb / 27°C wet bulb.

Pressure

85 kPa.

Manufacturer guidance

Nominal available pressure.

CompressorCapacity

2 L.

Compressor

One.

Manufacturer guidance

Number of compressors.

Power input

0.82 kW.

Manufacturer guidance

Total power input.

Sustainability data

Country of product manufacture

Italy

Material

Steel

Aluminium

Copper

Literature

Edge EVO 2.0 - EXC - WiSAN-YME 1 S 2.1-14.1 Range

Edge EVO 2.0 - EXC - WiSAN-YME 1 S 2.1-14.1 Range