NBS Source
I'm a manufacturer

Electric Lock Narrow (EL402-F/UN)

Verified by manufacturer 10 months ago

Abloy UK

Fail unlocked lock case for narrow profile doors.

Jump to:
+44 (0)1902 364500 Website

Application

  • Suitable for use in office and business premises, including exit doors with push pad PPE004, swing doors and doors with automatics.
  • Not suitable for doors with seal force or fire rated doors.

Description

Electromechanical, fail unlocked lock for narrow stile doors controlled by electrical impulse generating equipment such as card readers, keypads and timers or push and pull function.


Features and benefits:

  • Adjustable backset.
  • Non-handed, symmetrical trigger bolt.
  • Deadlocks automatically when the door closes.
  • Immediate release of deadlocking.
  • Configurable fail unlocked.
  • Wide operating voltage.

General information

Finish

Chrome

Guidance for specification option:

Plated forend.

Material

Steel

Size

-

Manufacturer guidance

Plate size.

Length

Bespoke

Width

25 mm

Height

225 mm

Uniclass

Pr_30_36_08_24 Door latchesPrimary

CAWS

P21/24 Door locks

P21/515 Door locks

Specification data - Door latches

Standard

To BS EN 12209.

Classification grades (minimum)

-

Category of use

BS EN 12209, grade 3.

Durability

BS EN 12209, grade C.

Door mass and closing force

BS EN 12209, grade 8.

Corrosion resistance and temperature

BS EN 12209, grade F.

Security and drill resistance

BS EN 12209, grade 3.

Key identification requirement

BS EN 12209, grade 0.

Latch or lock type

Cylinder mortice lock.

Backset

25 mm.

28 mm.

30 mm.

33 mm.

35 mm.

Material and finish

Chrome plated forend.

Latch spring strength

Select to prevent un-sprung lever handles drooping.

Execution

Fasteners for hardware.

Product Reference

Electric Lock Narrow (EL402-F/UN)

Forend

25 mm.

Operating voltage

12–24 V d.c.

Guidance for specification option:

-10%/+15%.

Power consumption

550–270 mA.

Guidance for specification option:

Max consumption at 12—24 VDC

(Idle consumption 240—110 mA at 12—24 VDC).

Operating temperature

-20 to +60°C.

Bolt

14.5 mm.

Manufacturer guidance

Throw bolt.

Configuration

Non-handed.

Guidance for specification option:

Symmetrical trigger bolt.

Failure mode

Fail unlocked.