NBS Source
I'm a manufacturer

Elite 54 FR30 - Wall System

Verified by manufacturer 8 months ago

Euroclad Group Ltd

Insulated built-up wall system with Opus planks as an external finish.

Jump to:
+44 (0)2922 010101 Website

Application

Suitable for facades and soffits within industrial, commercial and domestic settings.

Description

Euroclad Elite 54 Range is a modular, vertical cladding solution.


The system comprises Opus interlocking secret fix plank profiles fixed directly to the Quattro spacer system with compressed quilt insulation between the planks and the liner sheet.


This is a guaranteed system which also meets project specific thermal and acoustic performance requirements.


Features and benefits:

  • 0.7 mm EC Opus 25-150 Wall or EC Opus 25-200 Wall steel plank profile in vertical orientation.
  • 0.4 mm EC 19-167-1000 Liner trapezoidal internal steel profile.
  • Quattro Spacer System featuring Quattro Bar and Quattro Bracket.
  • 0.040λ (Lambda) quilt insulation.
  • External steel planks available in a range of coatings and colours.

General information

Color

White

Black

Grey

Beige

Cream

Show more

Finish

Coated

Material

Steel

Mineral wool

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

25 year

Guidance for specification option:

Guaranteed for up to 30 years with the Elite Plus system guarantee.

Uniclass

Ss_25_20_68_50 Metal profiled sheet self-supporting cladding systemsPrimary

CAWS

H31/10 Metal

H31/120 Metal

Specification data - Metal profiled sheet self-supporting cladding systems

System performance

Fire performance: To BS 476-22:1987, 120 minutes integrity, 30 minutes insulation.

Liner sheets

-

Material

Euroclad EC 19-167-1000 Liner 2 0.4 mm steel.

Primary fasteners

Carbon steel fixings.

Guidance for specification option:

Elite guarantee.

Stainless steel fixings.

Guidance for specification option:

Elite PLUS guarantee.

End and side laps

Stitched liner profile sidelaps.

Guidance for specification option:

300 mm maximum centres.

Air and vapour control layer

-

Material

Euroclad Elite VCL.

Euroclad Elite HH VCL.

Sealing

Euroclad Elite VCL Sealing Tape.

Euroclad Elite HH VCL Sealing Tape.

Spacers

Quattro Bar and 120 mm Quattro Bracket.

Guidance for specification option:

System depth: 140.40 mm.

System weight: 16.59 kg/m².

U-value: 0.35 W/m²K.

Quattro Bar and 140 mm Quattro Bracket.

Guidance for specification option:

System depth: 160.40 mm.

System weight: 17.14 kg/m².

U-value: 0.30 W/m²K.

Quattro Bar and 150 mm Quattro Bracket.

Guidance for specification option:

System depth: 170.40 mm.

System weight: 17.42 kg/m².

U-value: 0.29 W/m²K.

Quattro Bar and 160 mm Quattro Bracket.

Guidance for specification option:

System depth: 180.40 mm.

System weight: 17.70 kg/m².

U-value: 0.27 W/m²K.

Quattro Bar and 170 mm Quattro Bracket.

Guidance for specification option:

System depth: 190.40 mm.

System weight: 18.24 kg/m².

U-value: NPD.

Quattro Bar and 180 mm Quattro Bracket.

Guidance for specification option:

System depth: 200.40 mm.

System weight: 18.25 kg/m².

U-value: 0.24 W/m²K.

Quattro Bar and 185 mm Quattro Bracket.

Guidance for specification option:

System depth: 205.40 mm.

System weight: 18.79 kg/m².

U-value: NPD.

Quattro Bar and 200 mm Quattro Bracket.

Guidance for specification option:

System depth: 220.40 mm.

System weight: 18.80 kg/m².

U-value: 0.21 W/m²K.

Quattro Bar and 220 mm Quattro Bracket.

Guidance for specification option:

System depth: 240.40 mm.

System weight: 19.35 kg/m².

U-value: 0.20 W/m²K.

Quattro Bar and 240 mm Quattro Bracket.

Guidance for specification option:

System depth: 260.40 mm.

System weight: 19.90 kg/m².

U-value: 0.18 W/m²K.

Quattro Bar and 260 mm Quattro Bracket.

Guidance for specification option:

System depth: 280.40 mm.

System weight: 20.46 kg/m².

U-value: 0.17 W/m²K.

Quattro Bar and 280 mm Quattro Bracket.

Guidance for specification option:

System depth: 300.40 mm.

System weight: 21.01 kg/m².

U-value: 0.15 W/m²K.

Quattro Bar and 300 mm Quattro Bracket.

Guidance for specification option:

System depth: 320.40 mm.

System weight: 21.56 kg/m².

U-value: 0.14 W/m²K.

Quattro Bar and 320 mm Quattro Bracket.

Guidance for specification option:

System depth: 340.40 mm.

System weight: 22.11 kg/m².

U-value: 0.14 W/m²K.

Quattro Bar and 340 mm Quattro Bracket.

Guidance for specification option:

System depth: 360.40 mm.

System weight: 22.66 kg/m².

U-value: NPD.

Quattro Bar and 360 mm Quattro Bracket.

Guidance for specification option:

System depth: 380.40 mm.

System weight: 23.22 kg/m².

U-value: NPD.

Quattro Bar and 380 mm Quattro Bracket.

Guidance for specification option:

System depth: 400.40 mm.

System weight: 23.77 kg/m².

U-value: 0.10 W/m²K.

Quattro Bar and 400 mm Quattro Bracket.

Guidance for specification option:

System depth: 420.40 mm.

System weight: 24.32 kg/m².

U-value: 0.09 W/m²K.

Manufacturer guidance

Note: The weights shown are calculated with Opus 150 as this is the heaviest profile per square metre of the four options.

Thermal insulation

Rockwool Cladding Roll.

Guidance for specification option:

Declared lambda: 0.040 W/mK.

External sheets

-

Material

EC Opus 25-150 Wall (3 mm gaps) 0.7 mm steel Colorcoat HPS200 Ultra®.

EC Opus 25-200 Wall (3 mm gaps) 0.7 mm steel Colorcoat HPS200 Ultra®.

EC Opus 25-200 Wall (10 mm gaps) 0.7 mm steel Colorcoat HPS200 Ultra®.

EC Opus 25-200 Wall (20 mm gaps) 0.7 mm steel Colorcoat HPS200 Ultra®.

EC Opus 25-150 Wall (3 mm gaps) 0.7 mm steel Colorcoat Prisma®.

EC Opus 25-200 Wall (3 mm gaps) 0.7 mm steel Colorcoat Prisma®.

EC Opus 25-200 Wall (10 mm gaps) 0.7 mm steel Colorcoat Prisma®.

EC Opus 25-200 Wall (20 mm gaps) 0.7 mm steel Colorcoat Prisma®.

Primary fasteners

Carbon steel fixings.

Guidance for specification option:

Elite guarantee.

Stainless steel fixings.

Guidance for specification option:

Elite PLUS guarantee.

System accessories

Fasteners, flashings, membranes, tapes, mastic and sealants, fabrications.

Colour/ Finish

Alaska Grey (RAL 7000).

Guidance for specification option:

Colorcoat HPS200 Ultra®.

Colorcoat Prisma®.

Albatross (RAL 240 80 05).

Guidance for specification option:

Colorcoat HPS200 Ultra®.

Anthracite (RAL 7016).

Guidance for specification option:

Colorcoat HPS200 Ultra®.

Colorcoat Prisma®.

Aquarius.

Guidance for specification option:

Colorcoat Prisma®.


Ardenne (RAL 7022).

Guidance for specification option:

Colorcoat HPS200 Ultra®.

Show more

Sustainability data

Material

Steel

Mineral wool