NBS Source
I'm a manufacturer
Compare variants

elZinc Façade panel Cladding - Zinc Wall Cladding

Verified by manufacturer 1 month ago

Horizontal

elZinc Variant:
Third party certifications:
  • ISO 45001 Health and Safety Management

    Certificate type

  • ISO 14001 Environmental Management Systems

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • EnMS ISO 50001

    EnMS ISO 50001

    Certificate type

  • EPD

    EPD

    Certificate type

  • KIWA BDA

    KIWA BDA

    Certificate type

A cladding system composed of self-supporting interlocking zinc panels with shadow (reveal) joints.

Jump to:
+44 (0) 7933 171 956 Website

Application

Suitable for flat or gently curved facades and soffits.

Description

The elZinc® facade panel is a zinc architectural cladding solution composed of self-supporting interlocking zinc panels with shadow (reveal) joints. They are installed either horizontally or vertically, interlocking with one another to form a rear-ventilated rainscreen.


The zinc rear-ventilated rainscreen facade is composed of horizontally or vertically installed self-supporting panels made of 1 mm thick elZinc® titanium zinc rolled according to EN 988 and ASTM B69-13. Ventilating space behind cladding to be a minimum of 38 mm, or according to project design criteria, whichever is the greater. 


Features and benefits:

  • Single skin self-supporting panels with tongue and groove joint.
  • Narrow aspect ratio – length up to a nominal 4 m, width up to 300 mm.
  • Panels are normally installed in either a horizontal or vertical direction.
  • Installed top to bottom.
  • Reveal joint width between panels can vary from 5 mm to 25 mm.
  • System weight 10 kg/m² (zinc only).

General information

Color

Grey

Guidance for specification option:

Light grey, medium grey or dark grey.

Red

Blue

Brown

Gold

Show more

Finish

Natural

Pre-weathered

Material

Zinc

Guidance for specification option:

Titanium zinc.

Shape

Rectangle

Length

-

Manufacturer guidance

500-4000 mm.

Width

300 mm

Height

26 mm

Warranty description

Lifetime

Guidance for specification option:

Alkimi range.

20 year

Guidance for specification option:

Rainbow range.

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Zinc facade panels shall provide a rainscreen wall cladding, able to freely expand and contract in response to temperature changes, and fitted to resist all loading including wind loads. The appearance of the cladding shall be one composed of flat panels, of straight joints and neat folds, correctly set out according to the architect’s drawings and design intent.

Thermal insulation

-

Manufacturer guidance

A zinc façade does not place any special requirement on the insulation.

Breather membrane

-

Material

Not required.

Breather membrane.

Fasteners

A2 stainless steel self-drilling screws.

Secondary support structure

Metal rails on adjustable wall brackets.

Cladding panels

-

Material

1.0 mm-thick elZinc® zinc.

Guidance for specification option:

Joint centres 233-300 mm.

System accessories

Joints liners.

Execution

-

Manufacturer guidance

Joints shall set out according to architect’s drawings, or in their absence, according to the design intent of the project. The details of the zinc work should be carried out according recognized good practice and manufacturer’s recommendations. Respect minimum recommended interior radii while bending. Holes should be notched where required to prevent tears forming in the zinc. Marking out: Use a pencil, pen, crayon or chalk.


After completion, no marking should be visible. Wherever possible use a mechanical folder to bend material to give straight and uniform folds. Free edges: If visible fold over to form a 15 mm hem. Ensure the temperature of the metal does not fall below 7, or 10°C, depending on the operation, when folding, profiling or forming the metal. Follow elZinc recommendations regarding warming up zinc metal prior to forming.

Colour/ Finish

elZinc Crystal®.

elZinc Graphite®.

elZinc Lava®.

elZinc Natural.

elZinc Oliva®.

Show more

Manufacturer guidance

If a backside coating is required, type 'Protect+' directly after the finish, eg. elZinc Graphite® Protect+. If an ‘Advance’ finish is required, type ‘Advance’ directly after the finish, eg. elZinc Slate Advance.

Layout

Horizontal design with uniform horizontal and vertical shadow joint widths.

Guidance for specification option:

This is the simplest of designs and the most common. It gives a homogeneous feel to the facade. The shadow joint in both directions is usually between 10 and 15 mm. See image in Associated Content.

Horizontal design using sleeved transversal joints.

Guidance for specification option:

This reduces the impact of the transversal joints lending, in this design, more horizontality to the facade. See image in Associated Content.

Horizontal design using different joint widths.

Guidance for specification option:

This ‘frames’ blocks of panels and can create the illusion (at a distance) of large panel sizes. The heavier joints are normally made to coincide with openings.  See image in Associated Content.

Joint width

-

Manufacturer guidance

Insert requirements.


Longitudinal joint:

Labrynth (shadow joint): The width of the longitudinal joint can vary from 5-25 mm wide.


End to end joint:

  • Baffled (joint liner): 10-15 mm is normal, and must be above minimums established below.
  • Closed joint (Sleeved joint): Must be above minimums established below.

Width can vary from the minimums given below to 25 mm.


Minimum transverse joint widths:

  • 1 m panel – 4 mm.
  • 2 m panel – 5 mm.
  • 3 m panel – 7 mm.
  • 4 m panel – 8 mm.

Sustainability data

Contains Red List materials

No

Country of material origin

Spain

Country of product manufacture

Spain

Recyclability

100%

Guidance for specification option:

Fully recyclable.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

20 %

Guidance for specification option:

Approximate.

Third party certifications

Third party certifications

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO45001

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

ISO14001

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001

EnMS ISO 50001

EnMS ISO 50001

ISO 50001

ISO 14001 Environmental Management Systems

ISO 14001 Environmental Management Systems

ISO 50001

EPD

EPD

EPD elZinc Alkimi - Crystal, Slate, Oliva, Lava, Graphite

EPD

EPD

EPD elZinc Natural

KIWA BDA

KIWA BDA

KOMO Certificate

Literature

Architectural solutions in zinc

Architectural solutions in zinc

Explanatory leaflet elZinc Lifetime warranty

Explanatory leaflet elZinc Lifetime warranty

elZinc - The Material - General Considerations

elZinc - The Material - General Considerations

elZinc Color Chart

elZinc Color Chart

elZinc LEED Certification

elZinc LEED Certification