NBS Source
I'm a manufacturer
Compare variants

Energy

Verified by manufacturer over a year ago

Energy 65/41, double glazing

AGC Glass UK Ltd Variant:

Range of glazing for windows that blocks out excess incoming heat while maintaining a high level of thermal insulation and letting plenty of daylight in.

Jump to:
Website

Application

Residential buildings and homes.

Description

Range of glazing for windows that blocks out excess incoming heat while maintaining a high level of thermal insulation and letting plenty of daylight in.


Features and benefits:

  • Soft-coated glass combining solar control and low emissivity.
  • Energy-saving coatings lead to lower air conditioning and/ or heating costs.
  • High light transmission: Maximum natural light entering the building.
  • Multifunctional glass.
  • U-value of 1.0 W/m²K.
  • By regulating heat and cold, the glass provides optimal indoor comfort.
  • Cradle to Cradle Certified™ Silver.


Energy 65/41: Solar protection combined with a high level of daylight and high thermal insulation.


Energy 65/42 S: Solar protection combined with a high level of daylight and high thermal insulation. Single-stock. Can be used annealed and heat-treated.


Energy 72/38: High solar protection combined with a very high level of daylight and high thermal insulation.


Energy 72/38 T: Heat-treated version of Energy 72/38. It can not be used annealed.

General information

Color

Clear

Material

Glass

Uniclass

Pr_25_71_33_42 Insulated glass units (IGUs)Primary

CAWS

H10/10 Patent glazing

H10/115 Patent glazing

H11/110 Curtain walling

H13/115 Structural glass assembly

L10/10 Wood windows

L10/15 Wood windows

L10/20 Steel windows

L10/210 Wood windows

L10/25 Aluminium windows

L10/30 PVC-U windows

L10/31 PVC-U windows

L10/310 Steel windows

L10/33 Proprietary windows

L10/330 Aluminium windows

L10/350 PVC-U windows

L10/390 Proprietary windows

L10/400 Composite windows

L10/58 Secondary glazing system

L10/580 Secondary glazing system

L40/210 Putty-fronted single glazing

L40/230 Bead-fixed single glazing – non-setting compound

L40/250 Bead-fixed single glazing – tape and sealant

L40/260 Bead-fixed single glazing – extruded gasket

L40/310 Bead-fixed single glazing – tape, sealant and trim

L40/330 Bead-fixed single glazing – capping

L40/350 Bead-fixed single glazing – curing compound and trim

L40/370 Bead-fixed insulating glass units – insert gasket sections

L40/371 Bead-fixed insulating glass units – cellular adhesive/ mastic tape

L40/372 Bead-fixed insulating glass units – loadbearing tapes/ synthetic rubber and sealant capping

L40/380 Bead-fixed insulating glass units – solid bedding, outside bead

L40/381 Bead-fixed insulating glass units – solid bedding, inside bead

L40/40 Putty-fronted single glazing

L40/410 Single glazing into grooves – extruded rubber/ PVC sections

L40/430 Single glazing into grooves – non-setting compound

L40/450 Single glazing into grooves – sealant capping

L40/470 Zipper gasket glazing

L40/490 Single-sided gasket glazing

L40/50 Bead-fixed single glazing

L40/530 Internal tape glazing

L40/55 Bead-fixed insulating glass units – drained and ventilated bead

L40/57 Bead-fixed insulating glass units – solid bedding, outside bead

L40/58 Bead-fixed insulating glass units – solid bedding, inside bead

L40/90 Internal tape glazing

Specification data - Insulated glass units (IGUs)

General requirements

Glass generally

Standard

-

Manufacturer guidance

Consult manufacturer for details.

Third-party certification

Cradle to Cradle Certified™ Silver.

Pane arrangement

Double.

Guidance for specification option:

Coating position 2 unless stated otherwise.

Overall thickness

26 mm.

Guidance for specification option:

6-16-4.

25 mm.

Guidance for specification option:

6-15-4.

Performance requirements

-

Fire performance

-

Integrity

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Insulation

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Radiation

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Light

To EN 410:2011, Transmission: 65%; reflection: 24% (internal); 26% (external).

Solar control

To EN 410:2011, Solar factor: 42%.; energy absorption:21%.

Total shading coefficient

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Thermal insulation

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Sound attenuation

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Impact resistance

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Manifestation

-

Manufacturer guidance

Insert requirements.

Unit build up

-

Inner pane

-

Glass type

Manufacturer's standard, clear (neutral).

Thickness

4 mm.

Outer pane

-

Glass type

Manufacturer's standard, clear (neutral).

Thickness

6 mm.

Cavity space fill

Argon (90%).

Perimeter spacers

-

Requirement

16 mm.

Guidance for specification option:

Standard.

15 mm.

Manufacturer guidance

Note: Spacer size does not affect U-value.

Material

Manufacturer's standard.

Edge profile

Manufacturer's standard.

Thermal transmittance (U-Value)

To EN 673, 1.0 W/m²K.

Additional requirements

None.

Processing

Not applicable.

Literature

Energy

Energy