NBS Source
I'm a manufacturer
Compare variants

ESCORTA® Goods Lift

Verified by manufacturer 6 months ago

Cabin width >1500 mm

Lödige Industries Variant:

Efficient vertical goods-with-attendant lift.

Jump to:
01784 221140 Website

Application

Goods-with-attendant lift.

Applications include: production facilities; logistics and distribution centres; event and shopping centres; hospitals; public buildings; offices; hotels.

Description

Efficient vertical goods-with-attendant lift.


Features and benefits:

  • Can be easily integrated into existing buildings or rack systems.
  • Freestanding lift structure.
  • Tailor-made cabin dimensions.
  • Small pit depth.
  • No separate machine room necessary.
  • Double-brake system for superior safety.


Technical data Sherpa:

  • Load capacity: max. 4,500 kg.
  • Nominal speed: 0.2 m/s.
  • Lifting height: up to 18 m.
  • Cabin depth: up to 4,500 mm.
  • Cabin width: up to 2,800 mm.
  • Cabin height: up to 2,800 mm.
  • Number of stopping points: 2 to 6.
  • Door configuration: one side or through car loading.
  • Power train: electric with chain.
  • After machine directive 2006/42/EC and DIN EN 81-41 (on the basis).


Goods-only lift also available, specified separately (SHERPA®).

General information

Color

Beige

Black

Blue

Bronze

Brown

Show more

Manufacturer guidance

Contact manufacturer for any colour.

Finish

Galvanized

Powder-coated

Material

Steel

Shape

Rectangle

Length

Bespoke

Manufacturer guidance

Cabin depth: 1,600 to 4,500 mm

Width

Bespoke

Manufacturer guidance

Cabin width: 900 to 2,800 mm

Height

Bespoke

Manufacturer guidance

Cabin height: 1,800 to 2,800 mm

Warranty description

One year

Uniclass

Ss_80_50_60_26 Electric passenger and goods-passenger lift systemsPrimary

CAWS

X12/110 Vertical lifting platform systems

X12/110 Vertical lifting platform systems

Specification data - Electric passenger and goods-passenger lift systems

Lift type

Goods passenger lift.

Drive space

Machine room-less.

Lift components

Free-standing self-supporting lift shaft; cabin; integrated drive.

Guidance for specification option:

  • Steel lift shaft with sheet metal cladding. Supplied prime coated or galvanized.
  • Steel cabin with hinged doors (primed or painted). Ceiling is non-accessible as standard.
  • Drive: Integrated in the shaft head.
  • Control mounted on the shaft cabinet.
  • Energy-saving gear motor with double brake system.
  • LED cabin lighting.
  • Safety light beams.
  • Cabin operator panel (COP).
  • Landing operating panels (LOP).
  • Door flap, installed above each shaft end door.

Door arrangement

Single entrance (front only), two floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Single entrance (front only), three floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Single entrance (front only), four floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Single entrance (front only), five floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Single entrance (front only), six floors.

Guidance for specification option:

Number of entrances/ doors to match number of stops specified (See Lift height below).

Doors opposite/ through car, two floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (Two, three or four).


For each floor, define for each opening whether a double swing door or no door is required.

Doors opposite/ through car, three floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (Three, four, five or six).


For each floor, define for each opening whether a double swing door or no door is required.

Doors opposite/ through car, four floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (Four, five, six, seven or eight).


For each floor, define for each opening whether a double swing door or no door is required.

Doors opposite/ through car, five floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (Five, six, seven, eight, nine or ten).


For each floor, define for each opening whether a double swing door or no door is required.

Doors opposite/ through car, six floors.

Guidance for specification option:

Insert requirements for number of entrances/ doors (6, 7, 8, 9, 10, 11 or 12).


For each floor, define for each opening whether a double swing door or no door is required.

Drive position

Integrated in shaft head.

Speed control

Manufacturer's standard.

Rated load

-

Manufacturer guidance

Insert requirements; 500–4500* kg.

Individually configured lifts have a load range of 500–3000* kg.


Maximum load is also dependent on cabin size specified; consult manufacturer for full details.

Pit opening

Required.

Guidance for specification option:

Pit depth required is between 70 and 150 mm, dependent on load capacity. Consult manufacturer for details.

Not required (ramp).

Guidance for specification option:

Chequered plate metal, primed in RAL 9016 Pebble grey as standard.

Other colours and/ or a side bevel available on request.

Cabin

2000 x 2500 x 2000 mm.

Guidance for specification option:

Width x depth x height.

Bespoke.

Guidance for specification option:

Insert requirements:

  • Width: 1600–2800 mm.
  • Depth: 1200–4500 mm.
  • Height: 1800–2800 mm.

System accessories

None.

Frequency converter.

Fire-rated doors, E120/ EI05/ EW30.

Fire-rated doors, E120/ EI15/ EW60.

Door dampers.

Guidance for specification option:

Prevents the door slamming shut with subsequent noise generated. Also protects the door and the door hinges.

Note: Not classified as fire-resistant under EN 81-58.

Show more

Lift height

-

Manufacturer guidance

Insert requirements:

  • Lighting height: Up to 18 m.
  • Number of stops: Two to six.
  • Distance between floors.

Shaft

-

Manufacturer guidance

Insert requirements:

  • Depth: 1270–3600 mm.
  • Length: 1340–4840 mm.

Colour

Galvanized.

Powder-coated.

Guidance for specification option:

Consult manufacturer for colour options and insert requirements. All common Classic RAL colours are available (metallic and neon colours are not possible).

Manufacturer guidance

Shaft colour/ finish.

Control cabinet

-

Manufacturer guidance

Insert placement requirements:

  • Floor number;
  • Position (left or right).


Painted in RAL 7035 as standard.

Ingress protection: IP54 without a frequency converter; IP44 with a a frequency converter.

The size of the control cabinet will vary depending on the lift configuration; consult manufacturer for details.

Speed

0.15 m/s.

Door configuration

Double swing doors only.

Guidance for specification option:

Cabin width >1500 mm only.

Double swing/ no door combinations.

Guidance for specification option:

Cabin width >1500 mm only.

Specify front and back combinations of door/ no door requirements per floor.


Minimum of one door required per floor (adjust distance between floors if one level of the building is to be bypassed).

Manufacturer guidance

Door size determined by cabin size.

No door handle shells on the inside of the doors as standard.

Door colour

Traffic red.

Sky blue.

Dusty grey.

Primed (RAL 9016 Pebble grey).

Other, Classic RAL.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

All common Classic RAL colours are available (metallic and neon colours are not possible)

Landing operating panels

Manufacturer's standard, to left-hand side of door.

Manufacturer's standard, to right-hand side of door.

Communication

Autodialler, landline connection.

Autodialler, 2G GSM module.

Autodialler, 4G (LTE) GSM module.

Manufacturer guidance

Operated via the cabin panel; intercom is located in the cabin ceiling.

LED lighting

LED panel, light colour 840 (neutral white); 4000 K.

Guidance for specification option:

Output: 18 W; luminous flux: 1200 lm.

Flooring

Manufacturer's standard.

Guidance for specification option:

Smooth sheet metal with a two-component anti-slip coating (epoxy resin-based, solvent-free and non-slip coating in RAL 7040).

Steel tear plate.

Guidance for specification option:

Painted to match door colour.

Aluminium tear plate.

Manufacturer guidance

For lifts up to maximum 1000 kg nominal load and maximum 1400 mm cabin width, galvanized platforms are standard.

Sustainability data

Contains Red List materials

No

Country of product manufacture

Germany

Literature

ESCORTA goods lift brochure

ESCORTA goods lift brochure

Lifting Solutions Brochure

Lifting Solutions Brochure

SHERPA and ESCORTA Planning Guide

SHERPA and ESCORTA Planning Guide

Focus on Architecture

Focus on Architecture

ESCORTA Self Storage

ESCORTA Self Storage

Case studies

Customised goods lift matching corporate colour of Pink Hippo Self-Storage

Customised goods lift matching corporate colour of Pink Hippo Self-Storage

Efficient and safe goods lifts optimize performance for a large online shopping retailer’s warehouse

Efficient and safe goods lifts optimize performance for a large online shopping retailer’s warehouse

Easy installation of goods lift making transport more comfortable for German Wholesaler

Easy installation of goods lift making transport more comfortable for German Wholesaler

German online retailer improves its distribution centre performance

German online retailer improves its distribution centre performance