Verified by manufacturer 9 months ago
≥238 mm wall thickness.
Twin Timber stud insulated partition system.
Twin Timber stud insulated partition system.
Timber twin stud partition system based on fermacell® gypsum fibreboard linings. Homogeneous dry lining board made from recycled gypsum, recycled cellulose fibres from post-consumer waste paper and recycled water.
Features and benefits:
Color | Grey |
Material | Gypsum Guidance for specification option: fermacell® Gypsum-Fibreboard consists of a homogeneous mixture of water, gypsum and cellulose fibre compressed at high pressure. |
Shape | Rectangle |
Length | 2400 mm 2700 mm 3000 mm |
Width | 1200 mm |
Uniclass | |
CAWS | K10/15 Lining on timber K10/205 Lining on timber |
System performance | To EN 1364-1, 60 minute (EI) fire rated partition. |
Insulation | Mineral wool insulation.Guidance for specification option: 2 x 90 mm; 10 kg/m³. |
Linings | |
Inner layers | Two layers of 12.5 mm fermacell®. |
Fasteners | 40 mm fermacell® screws at 250 mm centres.44 mm + staples at 200 mm centres.50 x Ø 2.8 mm nails at 200 mm centres. |
Joint treatment | Inner layer, 1 mm (maximum) dry butt joints; Outer layer, fermacell® Jointstik 1 mm glued joint.Guidance for specification option: Square edged boards. Inner layer, 1 mm (maximum) dry butt joints; Outer layer, fermacell® Jointfiller 5–7 mm filled joint.Guidance for specification option: Site cut boards. |
Finish | Not required.fermacell® Fine Surface Treatment (FST). |
Execution | Installing framed partitions generally. |
System completion | Verification of performance. |
Timber studs | 89 x 38 mm. Guidance for specification option:
|
Finished wall thickness | ≥238 mm. |
Substructure | 89 x 38 mm. Guidance for specification option:
Manufacturer guidanceTimber stud (max. 600 mm centres). |
Base plate | 89 x 38 mm. Guidance for specification option:
Manufacturer guidanceHead / base plate. |
Thickness | 90 mm; 10 kg/m³. Manufacturer guidanceInsulation thickness / density. |
Board size | 2400 x 1200 mm. 2700 x 1200 mm. 3000 x 1200 mm. Manufacturer guidanceFermacell® fibre gypsum board. |
Density | 1150+50 kg/m³. Manufacturer guidancefermacell® fibre gypsum board. |
Water vapour diffusion resistance | 13 μ. Manufacturer guidancefermacell® fibre gypsum board. |
ThermalConductivity | 0.32 λ. Manufacturer guidancefermacell® fibre gypsum board. |
SpecificHeatCapacity | 1.1 kJ/kg·K. Manufacturer guidancefermacell® fibre gypsum board. |
Hardness | 30 N/mm². Manufacturer guidancefermacell® fibre gypsum board. |
ThicknessSwelling | <2%. Manufacturer guidancefermacell® fibre gypsum board. |
Shrinkage | 0.25 mm/m. Guidance for specification option: At 30% change in relative humidity (20°C). Manufacturer guidancefermacell® fibre gypsum board. Extension/shrinkage. |
MoistureContent | 1.3%. Guidance for specification option: At 65% relative humidity at 20 °C air temperature. Manufacturer guidancefermacell® fibre gypsum board. |
pH value | 7–8. Manufacturer guidancefermacell® fibre gypsum board. |
Usage | Type 1 and 2. Guidance for specification option: Usage classification to EN 1995-1. Manufacturer guidancefermacell® fibre gypsum board. |
ThermalExpansionCoefficient | 0.0001%/K. Manufacturer guidancefermacell® fibre gypsum board. |
Sound performance | Rw 64 dB. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 100 % Guidance for specification option: Best Fermacell gypsum fibreboard contains 100% recycled content. All by-products recyclable. |