Verified by manufacturer 9 months ago
130 mm wall thickness
Independent lining system based on fermacell® Firepanel A1.
Independent dry linings. Suitable for public buildings where dry construction methods are used.
Independent, metal stud lining system based on fermacell® Firepanel A1. fermacell® Firepanel A1 is a new dimension in fire protection for dry linings. The innovative development of the original fermacell® Gypsum Fibreboard complies with construction materials class A1 (non-combustible). A1 classification for linings are increasingly being specified throughout Europe for public buildings where dry construction methods are used. The reason is the harmonisation of fire safety tests and fire protection classifications, which have resulted in more stringent national requirements for construction materials and building elements
Features and benefits:
Color | Grey Manufacturer guidanceBoard colour. |
Finish | Unfinished Manufacturer guidancePainted ,Tiled, as required. |
Material | Gypsum Guidance for specification option: Homogeneous fibre-reinforced gypsum board with paper fibres and additives of non-combustible fibres. |
Shape | Rectangle |
Length | 2000 mm 1500 mm |
Width | 1250 mm 1000 mm |
Uniclass | |
CAWS | K10/30 Metal stud K10/155 Wall lining system (metal studs) |
System performance | To EN 1364-1, EI 60 minute fire rated lining. |
Framing | 100 mm fermacell® steel studs.Guidance for specification option: 50 mm fixing face, 0.6 mm gauge. |
Insulation | Not required. |
Fire separation | |
Cavity fire barriers | Fire-resistant gypsum plasterboards |
Fire-stopping | To EN 13501-1, class A1 non-combustible. |
Linings | |
Inner layers | 15 mm fermacell® Firepanel A1. |
Face layer | 15 mm fermacell® Firepanel A1. |
Fasteners | Inner layer, 30 fermacell® screws; Outer layer, fermacell® screws and 25–28 mm diverging staples.Guidance for specification option:
|
Joint treatment | fermacell® Jointstik 1 mm glued joint.Guidance for specification option: Square edged boards. fermacell® Jointfiller 5–7 mm filled joint.Guidance for specification option: For site cut boards. |
Finish | Not required.fermacell® Fine Surface Treatment (FST). |
System accessories | Manufacturer guidanceUse correct accessories as per manufacturers guidelines. Insert requirements. |
Execution | Manufacturer guidanceInstalling framed partitions generally. |
System completion | Verification of performance. |
WallThickness | 130 mm. |
Substructure | 100 x 0.6 mm. Manufacturer guidanceMax. 600 mm centres. |
Density | 1200 + 50 kg/m³. Manufacturer guidanceFirepanel A4 board. |
Flexural strength | > 5.8 N/mm². Manufacturer guidanceFirepanel A4 board. |
Water vapour diffusion resistance | 16 μ. Guidance for specification option: To EN ISO 12572. Manufacturer guidanceFirepanel A4 board. |
ThermalConductivity | 0.38 W/mK. Guidance for specification option: To DIN EN 12667. Manufacturer guidanceFirepanel A4 board. |
Shrinkage | 0.25 mm/m. Guidance for specification option: At 30% change in relative humidity (20°C). According to EN 318. Manufacturer guidanceFirepanel A4 board. |
MoistureContent | 1.30 %. Guidance for specification option: At 65% relative humidity at 20 °C air temperature. To EN 322. Manufacturer guidanceFirepanel A4 board. |
CompressiveStrength | > 18 N/mm². Manufacturer guidanceFirepanel A4 board. |
pH value | 7–8. Manufacturer guidanceFirepanel A4 board. |
Elasticity | > 4500 N/mm². Manufacturer guidanceFirepanel A4 board. |
Sheathing board | 2 x 15 mm. |
Sound performance | ≥ 22 dB. |
Board size | 1500 x 1000 mm. 2000 x 1250 mm. |