Verified by manufacturer 17 days ago
ISO 140-3/ ISO 717-1 Sound Reduction Index Test Report
Certificate type
Single glazed fire rated timber framed partition system.
All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public. Consult manufacturer for details.
Single glazed fire rated timber framed partition system. Part of a range of single or double glazed partition systems with fire insulation of Ei30 or Ei60 (other formats specified separately).
Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Other Guidance for specification option: Paint colour/ gloss level to be determined by specifier. |
Finish | Natural Primed Painted |
Material | Timber Guidance for specification option: Hardwood timber ≥640 kg/m³. Glass |
Warranty description | Manufacturer guidanceDealt with on a project specific basis as part of the O&M process; consult manufacturer for details. |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Product range |
Third party accreditation | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.Guidance for specification option: EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | |
Thickness | 95 mm. |
Partition height (nominal) | Manufacturer guidance3000 mm maximum; consult with manufacturer to ensure compliance with certification. |
Width (nominal) | Manufacturer guidanceRestricted minimum and maximum widths - consult with manufacturer to ensure compliance with certification. |
Deflection allowance (maximum) | |
Floor | Manufacturer guidanceConsult with manufacturer for system weight. |
Verticals | 50 mm deep x 95 mm wide. |
Panel partition type | Frameless glass - centre glazed. |
Framing, junctions, corners | 50 mm deep x 95 mm wide.Manufacturer guidanceCorners: Solid Post 95 x 95 mm. |
Joint treatment | |
Type | Butt jointed glazing; single centre glazed.Guidance for specification option: Consult with manufacturer to ensure compliance with test/assessment data. |
Finish and colour | Coloured silicone.Guidance for specification option: Consult manufacturer and insert requirements. |
Glazed panels | |
Type | Single centre glazed: 25 mm annealed multi-laminate fire glass.Guidance for specification option: Consult with manufacturer to ensure compliance with test/assessment data. |
Door arrangement | |
Type | 54 mm timber, single leaf door, single action.54 mm timber, unequal leaf doors, single action.54 mm timber, double leaf doors, single action. |
Door frames | Stand alone doorset 65 mm deep x 95 mm wide.With side or fanlight glazing 115 mm deep x 95 mm wide. |
Door leafs | |
Type | Halspan 54 mm Prima Core (IFCA/06167).Halspan 54 mm Optima Core (PAR/1034/01A:C01).Falcon 54 mm Streboard Core (IFCA/08038. |
Vision panels | Required.Guidance for specification option: Restricted to sizes within fire certification - consult with manufacturer and insert requirements. Not required. |
Ceiling | |
Type | Manufacturer guidanceFire rated construction - consult with manufacturer for interface detail and insert requirements. |
Method of support | Manufacturer guidanceConsult manufacturer for support detail and insert requirements. |
Perimeters, skirtings, sills | 50 mm deep x 95 mm wide. |
Hardware | Manufacturer guidanceConsult manufacturer and insert requirements. |
Seals | Intumescent silicone; Fire rated Solar PVC-U translucent ‘H’ joint. |
Cable management and outlets | Manufacturer guidanceConsult manufacturer and insert requirements. |
Other features | Manufacturer guidanceConsult manufacturer and insert requirements. |
Manifestation | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Guidance for specification option: Insert requirements. Artwork and custom manifestation to client design. Guidance for specification option: Insert requirements. Manufacturer guidanceTo architects choice and in accordance with the requirements of Approved Document K. |
StrengthGrade | Manufacturer guidanceConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
|
Acoustic performance | 40 dB Rw. |
Fire insulation | Ei60 (60/60 Integrity and Insulation). |
Partition | Frameless glass - single centre glazed. |
Fasteners | To manufacturer's specification, type, length and frequency to suit substrates. |
Joint treatment | Butt jointed glazing. |
Samples required | Manufacturer guidanceConsult with manufacturer. |
Finish/ Colour | Natural timber finish. Factory primed. Wet spray to match RAL colour. Guidance for specification option: Insert requirements, including gloss levels. |
Contains Red List materials | No Guidance for specification option: No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Timber Guidance for specification option: Hardwood timber ≥640 kg/m³. Glass |
Recyclability | 100% Guidance for specification option: Timber and glass. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 28 % Guidance for specification option: 17–28% for glass. |
2D Demountable Relocatable Crosswall System - Modular Wall System
Align Flush Bonded Glazed Pivoting Door - Pivoting Door
FireClear100 Double Glazed Partition System
FireClear20 Single Glazed Partition System
FireClear54 Double Glazed Partition System
FireEco Ei30 Double Glazed Timber Framed Fire Rated Glass Partition System
FireEco Ei30 Single Glazed Timber Framed Fire Rated Glass Partition System
FireEco Ei60 Double Glazed Timber Framed Fire Rated Glass Partition System
FirePro E120 Single Glazed Fire Rated Glass Partition System and Ei60 Fire Door
FirePro E30 Double Glazed Fire Rated Glass Partition System and Fire Door