Verified by manufacturer 17 days ago
Single glazed partition system and doorset with an Ei120 (120/120) fire rating.
All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public.
Consult manufacturer for details.
Single glazed partition system and doorset with an Ei120 (120/120) fire rating. FirePro partitions and doorsets are available in a range of glazing and performance options (specified separately).
Please note that acoustic, fire rated and structural certification and support for our products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Other Guidance for specification option: RAL colour. Silver Guidance for specification option: Stainless steel. |
Finish | Powder-coated Guidance for specification option: Polyester. Satin Guidance for specification option: 240 grit satin polished stainless steel. |
Material | Stainless steel Steel Glass |
Shape | Other Guidance for specification option: To suit project requirements; consult manufacturer for details. |
Length | Bespoke Guidance for specification option: To suit project requirements; consult manufacturer for details. |
Width | Bespoke Guidance for specification option: To suit project requirements; consult manufacturer for details. |
Height | Bespoke Guidance for specification option: To suit project requirements; consult manufacturer for details. |
Warranty description | Manufacturer guidanceConsult manufacturer for details. |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Product range |
Third-party certification | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold Acclaim (SIPP), Achilles (Building confidence, SIPP), EPD - material accreditation & compliance; FIS Member, Considerate Constuction, FORS Bronze; Build Profile.Guidance for specification option: EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | |
Thickness | Manufacturer guidance120 mm deep x 94 mm wide. |
Partition height (nominal) | Manufacturer guidanceConsult with manufacturer to ensure compliance with certification. |
Width (nominal) | Manufacturer guidanceConsult with manufacturer to ensure compliance with certification. |
Deflection allowance (maximum) | |
Head | +/- 20 deflection head 175 mm deep x 127 mm wide.Guidance for specification option: Certain configurations not available with deflection option - Consult with manufacturer for details. Manufacturer guidanceDeflection allowance head. |
Floor | Manufacturer guidanceConsult with manufacturer for system weight. |
Panel partition type | Framed glass - single centre glazed. |
Framing, fixing points and joints | Corners: framed 120 mm deep x 75 mm wide. |
Joint treatment | |
Type | Mullion: 120 mm deep x 94 mm wide; Transom: 120 mm deep x 75 mm wide. |
Finish and colour | Polyester powder-coated, RAL.Guidance for specification option: Framed. Insert requirements. 240 grit satin polished.Guidance for specification option: Framed. Silicone.Guidance for specification option: Frameless. |
Glazed panels | |
Type | Single centre glazed: 54 mm fire glass.Guidance for specification option: Consult with manufacturer to ensure compliance with test/ assessment data. |
Ceiling | |
Type | Manufacturer guidanceConsult with manufacturer for interface detail. |
Method of support | Manufacturer guidanceConsult with manufacturer for interface detail. |
Perimeters, skirtings, sills | 120 mm deep x 67 mm wide. |
Seals | Kerafix ceramic fibre tape. |
Cable management and outlets | Not required.120 mm deep x 250–400 mm tech panel. |
Other features | Manufacturer guidanceFanlights, sidelight and screens; consult with manufacturer and insert requirements. |
Manifestation | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Guidance for specification option: Insert requirements. Artwork and custom manifestation to client design. Guidance for specification option: Insert requirements. Manufacturer guidanceTo architects choice and in accordance with the requirements of Approved Document K. |
StrengthGrade | Manufacturer guidanceConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
|
Acoustic performance | Glazing: 47 dB Rw (through glass only). |
Fire insulation | Ei120 (120/120 Integrity and Insulation). |
Fasteners | To manufacturers specification, type, length and frequency to suit substrates. |
System accessories | None. Steel upstand support framework. Guidance for specification option: To floor void providing fire certification from slab to soffit. |
Samples required | Manufacturer guidanceConsult with manufacturer and insert requirements. |
Contains Red List materials | No Guidance for specification option: No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Stainless steel Steel Glass |
Recyclability | 100% Guidance for specification option: Up to 100% for glass and steel. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidance17–28% (glass)/ 15–20% (steel). |