Verified by manufacturer 15 days ago
Single glazed, minimum framed partition system and doorset with an Ei30 (30/30) fire rating.
All sectors: Commercial, Education, Healthcare, MOD, Airport & Rail, Industrial, Hospitality, Residential, & Public.
Consult manufacturer for details.
Single glazed, minimum framed partition system and doorset with an E3i0 (30/30) fire rating.
Features and benefits:
Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Other Guidance for specification option: Polyester powder-coated, RAL. Silver Guidance for specification option: Stainless steel. |
Finish | Satin Guidance for specification option: 240 grit satin polished stainless steel. |
Material | Steel Stainless steel Glass |
Shape | Manufacturer guidanceTo suit project requirements; consult manufacturer for further details. |
Warranty description | Manufacturer guidanceDealt with on a project specific basis as part of the O&M process; consult manufacturer for details. |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Product range |
Third party accreditation | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.Guidance for specification option: EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | |
Thickness | 55 mm.Guidance for specification option: 70 mm deep x 55 mm wide box and bead. |
Partition height (nominal) | Manufacturer guidanceConsult with manufacturer to ensure compliance with certification and insert requirements. |
Width (nominal) | Manufacturer guidanceConsult with manufacturer to ensure compliance with certification and insert requirements. |
Deflection allowance (maximum) | |
Floor | Manufacturer guidanceConsult with manufacturer for system weight. |
Verticals | ±15 deflection, 99 mm deep x 83 mm wide box and bead. |
Panel partition type | Framed glass - centre glazed. |
Framing, junctions, corners | Base: 70 mm deep x 56 mm wide box and bead; Abutment: 70 mm deep x 60 mm wide box and bead.Manufacturer guidanceCorners: 130 x 60 mm framed corner. |
Joint treatment | |
Type | Framed glazing, single centre glazed.Guidance for specification option: 90 mm deep x 60 mm wide mullion. Consult with manufacturer to ensure compliance with test/ assessment data. |
Finish and colour | Polyester powder-coated, RAL.Guidance for specification option: Insert colour requirement/ gloss level. 240 grit satin polished stainless steel. |
Glazed panels | |
Type | Single centre glazed: 17 mm annealed multi-laminate fire glass.Guidance for specification option: Consult with manufacturer to ensure compliance with test/assessment data. |
Door arrangement | |
Type | Micro-framed single leaf door, single action.Micro-framed single leaf door, double action.Micro-framed unequal leaf doors, single action.Micro-framed unequal leaf doors, double action.Micro-framed double leaf doors, single action.Micro-framed double leaf doors, double action. |
Door frames | 56 mm deep x 50 mm wide head, 36 mm deep x 60 mm wide stiles. |
Door leafs | |
Type | Fully glazed 17 mm annealed multi-laminate fire glass with micro frame.Guidance for specification option: Micro frame to glazed leaf:
|
Ceiling | |
Type | Manufacturer guidanceFire rated construction - consult with manufacturer for interface detail and insert requirements. |
Method of support | Manufacturer guidanceConsult manufacturer for support detail and insert requirements. |
Perimeters, skirtings, sills | Base: 70 mm deep x 56 mm wide box and bead; Abutment: 70 mm deep x 60 mm wide box and bead.Manufacturer guidanceCorners: 130 x 60 mm framed corner. |
Hardware | Manufacturer guidanceConsult manufacturer and insert requirements:
Access control:
|
Seals | Intumescent silicone. |
Other features | Manufacturer guidanceFanlights, sidelight and screens are available; consult with manufacturer and insert requirements |
Manifestation | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Guidance for specification option: Insert requirements. Artwork and custom manifestation to client design. Guidance for specification option: Insert requirements. Manufacturer guidanceTo architects choice and in accordance with the requirements of Approved Document K. |
StrengthGrade | Manufacturer guidanceConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
|
Acoustic performance | Circa 35 dB Rw. |
Fire insulation | Ei30 (30/30 Integrity and Insulation). |
Partition | Framed system - single centre glazed. |
Fasteners | To manufacturer's specification, type, length and frequency to suit substrates. |
Joint treatment | Mullions and transoms. |
Samples required | Manufacturer guidanceConsult with manufacturer. |
Finish/ Colour | Polyester powder-coated RAL or 240 grit satin polished stainless steel. Guidance for specification option: See 'Joint treatment: Finish and colour' above for details. |
Contains Red List materials | No Guidance for specification option: No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Steel Stainless steel Glass |
Recyclability | 100% Guidance for specification option: Steel and glass. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidance17–28% for glass. 15–20% for steel. |